A CONVENIENT MULTIPLE SOURCE MODEL FOR VARIAN 2300C 6 MV-X BEAM BASED ON MONTE CARLO SIMULATED LINAC

被引:0
作者
Lin, Hui [1 ]
Xu, Liangfeng [2 ]
Jing, Jia [3 ]
Li, Guoli [4 ]
Zhu, Yang [5 ]
Wu, Dong-Sheng [6 ]
Xu, Yuan-Ying [1 ]
Wu, Yican [3 ]
机构
[1] Hefei Univ Technol, Dept Appl Phys, Hefei 230009, Anhui, Peoples R China
[2] Hefei Univ Technol, Sch Comp & Informat, Hefei 230009, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[4] Zhejiang Univ Technol, Sch Informat Engn, Hangzhou 310014, Zhejiang, Peoples R China
[5] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei 230009, Anhui, Peoples R China
[6] Hefei Univ Technol, Res & Adm Dept, Hefei 230009, Anhui, Peoples R China
关键词
multiple source model; Monte Carlo simulation; external radiotherapy; RADIOTHERAPY;
D O I
10.13182/NT09-A9294
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Photon external radiotherapy of cancer takes advantage of the physical interaction of the photon and the secondary electron with biological tissue to kill cancer cells. The current linac is important equipment for producing an X-ray. The Monte Carlo method has been demonstrated to be the most accurate method for radiotherapy issues such as dose calculation and plan verification. However, its application in the clinic requires detailed information on the beam characteristics. A large quantity of the consumptive time for multiple simulation phases, such as linac treatment head simulation, beam trimmer module simulation, and patient/phantom simulation, and storage for the phase-space file (PSF), which records the information of the transported particle, are two knotty issues also. Therefore, a set of simple and convenient multiple source models (MSMs) including five sub-sources for regular fields from 3 X 3 cm to 30 X 30 cm was built, which is based on a VARIAN 2300C 6 MV-X beam simulated by the Monte Carlo code BEAMnrc and produced by BEAMnrc's beam characteristics analysis utility BEAMDP (BEAM Data Processor). This MSM reduced the three simulation phases to one to effectively decrease the consumptive time. The storage issue about the PSF was also solved for MSM's small volume. The dose distribution of the five-source model in a homogeneous phantom was compared with that of the full linac simulation and measurement data to verify reliability. The characteristics of the subsources were analyzed to present their feature. This work provided the base for implementing the Monte Carlo algorithm into the Accurate Radiotherapy System.
引用
收藏
页码:706 / 712
页数:7
相关论文
共 10 条
[1]   Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning [J].
Deng, J ;
Guerrero, T ;
Ma, CM ;
Nath, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1689-1704
[2]   Photon beam characterization and modelling for Monte Carlo treatment planning [J].
Deng, J ;
Jiang, SB ;
Kapur, A ;
Li, JS ;
Pawlicki, T ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :411-427
[3]   A multiple source model for 6 MV photon beam dose calculations using Monte Carlo [J].
Fix, MK ;
Stampanoni, M ;
Manser, P ;
Born, EJ ;
Mini, R ;
Rüegsegger, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1407-1427
[4]  
LIN H, 2008, CHINESE J NUCL PHYS, V25, P254
[5]   Accurate characterization of Monte Carlo calculated electron beams for radiotherapy [J].
Ma, CM ;
Faddegon, BA ;
Rogers, DWO ;
Mackie, TR .
MEDICAL PHYSICS, 1997, 24 (03) :401-416
[6]  
MA CM, 2004, 509 PIRS US NUCL REG
[7]   ENERGY AND ANGULAR-DISTRIBUTIONS OF PHOTONS FROM MEDICAL LINEAR ACCELERATORS [J].
MOHAN, R ;
CHUI, C ;
LIDOFSKY, L .
MEDICAL PHYSICS, 1985, 12 (05) :592-597
[8]   BEAM - A MONTE-CARLO CODE TO SIMULATE RADIOTHERAPY TREATMENT UNITS [J].
ROGERS, DWO ;
FADDEGON, BA ;
DING, GX ;
MA, CM ;
WE, J ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :503-524
[9]  
WALTERS B, 2007, PIRS794 US NUCL REG
[10]  
[吴宜灿 Wu Yican], 2005, [中国医学物理学杂志, Chinese Journal of Medical Physics], V22, P683