Bivariate Dependent Rate Analyses for Fault Identification in Transformer Windings during Impulse Test

被引:0
作者
Velandy, Jeyabalan [1 ]
机构
[1] Crompton Greaves Ltd, Global R&D Ctr, Kanjur Marg E, Bombay 400042, Maharashtra, India
关键词
Transformer; transformer windings; insulation failures; impulse test; interpretation techniques; LOCATION;
D O I
10.1109/TDEI.2015.004759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Identification of winding insulation failure during lightning impulse testing of transformer has been an important issue over a long period of time. It requires a significant human expertise and knowledge for proper judgment of transformer insulation. In this paper, the bivariate dependent rate analyses are proposed to identify the failure in transformer windings. The proposed analyses enable the calculation of winding response due to any impulse voltage excitation of full wave (FW) and chopped wave impulse (CW) for typical transformers. Initially, the line of best-fit on the scatter diagram is utilized to visualize the similarities between the measured winding responses and also to identify the type of relationship with potential outliers. Further, ellipse analysis is utilized to calculate the diversification (size, shape and orientation) between the responses. The actual interdependency between winding responses is established through nonlinear interpretation coefficients. To prove the feasibility of the analyses, 66.7 MVA, 90 MVA, 150 MVA, 250 MVA transformers, 80 MVAr reactor and 22 kV interleaved winding are used.
引用
收藏
页码:3592 / 3599
页数:8
相关论文
共 12 条
[1]  
[Anonymous], 2013, International standard IEC 60076-3
[2]  
[Anonymous], 2011, C57982011 IEEE
[3]  
[Anonymous], 2015, IEC standard 60270
[4]  
IEC, 2013, INSTRUMENTS SOFTWARE
[5]   Statistical Techniques for Partial-Discharge Location in Transformer Windings [J].
Jeyabalan, V. ;
Usa, S. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) :2064-2065
[6]   Frequency Domain Correlation Technique for PD Location in Transformer Winding [J].
Jeyabalan, V. ;
Usa, S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (04) :1160-1167
[7]  
Jeyabalan V., 2015, IEEE T POWER DELIVER
[8]  
Karsai K., 1987, LARGE POWER TRANSFOR
[9]   Partial discharges during impulse tests [J].
Kumaravelu, C ;
Sarathi, R ;
Jayashankar, V ;
Usa, S ;
Udayakumar, K .
2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, :616-619
[10]   Lineage-dependent rates of evolutionary diversification: analysis of bivariate ellipses [J].
Ricklefs, RE ;
Nealen, P .
FUNCTIONAL ECOLOGY, 1998, 12 (06) :871-885