Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan

被引:160
|
作者
Janegitz, Bruno C. [1 ]
Marcolino-Junior, Luiz H. [2 ]
Campana-Filho, Sergio P. [3 ]
Faria, Ronaldo C. [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-80060000 Curitiba, PR, Brazil
[3] Univ Sao Paulo, Inst Quim Sao Carlos, BR-05508 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbon nanotubes; Crosslinked chitosan; Copper determination; Anodic stripping voltammetry; ION ADSORPTION; AQUEOUS-SOLUTION; HEAVY-METALS; REACTIVE DYE; HG(II) IONS; MEMBRANES; LINKING; CHITIN; BEADS; WATER;
D O I
10.1016/j.snb.2009.08.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L-1 KNO3 with pH adjusted to 2.25 with HNO3, an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L-1 KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L-1 with a detection limit of 1.00 x 10(-8) mol L-1. The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [41] Anodic stripping voltammetric determination of arsenic(III) using a glassy carbon electrode modified with gold-palladium bimetallic nanoparticles
    Lan, Yuecun
    Luo, Hanjin
    Ren, Xiaohui
    Wang, Yiping
    Liu, Yuze
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 153 - 161
  • [42] Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode
    Hongchao Yi
    Analytical and Bioanalytical Chemistry, 2003, 377 : 770 - 774
  • [43] A mercury free electrode for anodic stripping voltammetric determination of Pb (II) ions using poly zincon film modified electrode
    Vasanthi, S.
    Devendiran, M.
    Narayanan, S. Sriman
    APPLIED SURFACE SCIENCE, 2017, 422 : 138 - 146
  • [44] ANODIC STRIPPING VOLTAMMETRIC DETERMINATION OF LEAD USING A CHEMICALLY MODIFIED ELECTRODE BASED ON AZA CROWN ETHER
    Segura, Rodrigo
    Diaz, Karina
    Pizarro, Jaime
    Placencio, Alan
    Tapia, Diego
    Fajardo, Angelo
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2017, 62 (04): : 3726 - 3730
  • [45] Adsorptive voltammetric determination of cisapride on carbon nanotubes paste electrode
    Zheng Li
    Song Jun-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1018 - 1020
  • [46] Fabrication of a new carbon paste electrode modified with multi-walled carbon nanotube for stripping voltammetric determination of bismuth(III)
    Fathirad, Fariba
    Afzali, Daryoush
    Mostafavi, Ali
    Shamspur, Tayebeh
    Fozooni, Samieh
    ELECTROCHIMICA ACTA, 2013, 103 : 206 - 210
  • [47] Square wave voltammetric determination of Hg(II) using thiol functionalized chitosan-multiwalled carbon nanotubes nanocomposite film electrode
    Deng, Wenfang
    Tan, Yueming
    Li, Yunyong
    Wen, Yanqing
    Su, Zhaohong
    Huang, Zhao
    Huang, Suqing
    Meng, Yue
    Xie, Qingji
    Luo, Yueping
    Yao, Shouzhuo
    MICROCHIMICA ACTA, 2010, 169 (3-4) : 367 - 373
  • [48] Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead
    Jovanovski, V.
    Hrastnik, N. I.
    Hocevar, S. B.
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 : 1 - 4
  • [49] Voltammetric Determination of Carbidopa Using a modified Multiwall Carbon Nanotube Paste Electrode
    Mohadesi, Alireza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2430 - 2439
  • [50] Determination of Trace Tl(I) by Differential Pulse Anodic Stripping Voltammetry Using a Novel Modified Carbon Paste Electrode
    Ghanei-Motlagh, Masoud
    Baghayeri, Mehdi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)