Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan

被引:160
|
作者
Janegitz, Bruno C. [1 ]
Marcolino-Junior, Luiz H. [2 ]
Campana-Filho, Sergio P. [3 ]
Faria, Ronaldo C. [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-80060000 Curitiba, PR, Brazil
[3] Univ Sao Paulo, Inst Quim Sao Carlos, BR-05508 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbon nanotubes; Crosslinked chitosan; Copper determination; Anodic stripping voltammetry; ION ADSORPTION; AQUEOUS-SOLUTION; HEAVY-METALS; REACTIVE DYE; HG(II) IONS; MEMBRANES; LINKING; CHITIN; BEADS; WATER;
D O I
10.1016/j.snb.2009.08.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L-1 KNO3 with pH adjusted to 2.25 with HNO3, an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L-1 KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L-1 with a detection limit of 1.00 x 10(-8) mol L-1. The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [31] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Roa, G
    Ramírez-Silva, MT
    Romero-Romo, MA
    Galicia, L
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 763 - 769
  • [32] Anodic stripping voltammetric measurement of trace cadmium at antimony film modified sodium montmorillonite doped carbon paste electrode
    Chen, Guo
    Hao, Xia
    Li, Bang Lin
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 : 570 - 574
  • [33] Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode
    El Harmoudi, H.
    Achak, M.
    Farahi, A.
    Lahrich, S.
    El Gaini, L.
    Abdennouri, M.
    Bouzidi, A.
    Bakasse, M.
    El Mhammedi, M. A.
    TALANTA, 2013, 115 : 172 - 177
  • [34] Simultaneous determination of cadmium (II), lead (II), copper (II) and mercury (II) by square-wave anodic stripping voltammetry at a montmorillonite-calcium modified carbon paste electrode
    Beltagi, Amr M.
    Ghoneim, Enass M.
    Ghoneim, Mohamed M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (01) : 17 - 32
  • [35] Differential Pulse Anodic Stripping Voltammetric Determination of Lead (II) Using Poly Xylenol Orange Modified Electrode
    Manikandan, Ramalingam
    Narayanan, Sangilimuthu Sriman
    ELECTROANALYSIS, 2017, 29 (02) : 609 - 615
  • [36] Voltammetric determination of l-dopa in the presence of tryptophan using a modified carbon nanotubes paste electrode
    Beitollahi, Hadi
    Taher, Mohammad Ali
    Keshtkar, Nasrin
    Sensor Letters, 2014, 12 (01) : 183 - 190
  • [37] Mercury Free Anodic Stripping Voltammetric Determination of Pb(II) Using a Low Cost “Cocos nucifera” Shell Modified Carbon Paste Electrodes
    Deepak Singh Rajawat
    Shalini Srivastava
    Soami Piara Satsangee
    National Academy Science Letters, 2014, 37 : 547 - 553
  • [38] Mercury Free Anodic Stripping Voltammetric Determination of Pb(II) Using a Low Cost "Cocos nucifera" Shell Modified Carbon Paste Electrodes
    Rajawat, Deepak Singh
    Srivastava, Shalini
    Satsangee, Soami Piara
    NATIONAL ACADEMY SCIENCE LETTERS-INDIA, 2014, 37 (06): : 547 - 553
  • [39] Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode
    Yi, HC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 770 - 774
  • [40] Anodic stripping voltammetric determination of silver(I) at a carbon paste electrode modified with S2O2-donor podand
    Ha, KS
    Kim, JH
    Ha, YS
    Lee, SS
    Seo, ML
    ANALYTICAL LETTERS, 2001, 34 (05) : 675 - 686