Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan

被引:160
|
作者
Janegitz, Bruno C. [1 ]
Marcolino-Junior, Luiz H. [2 ]
Campana-Filho, Sergio P. [3 ]
Faria, Ronaldo C. [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-80060000 Curitiba, PR, Brazil
[3] Univ Sao Paulo, Inst Quim Sao Carlos, BR-05508 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbon nanotubes; Crosslinked chitosan; Copper determination; Anodic stripping voltammetry; ION ADSORPTION; AQUEOUS-SOLUTION; HEAVY-METALS; REACTIVE DYE; HG(II) IONS; MEMBRANES; LINKING; CHITIN; BEADS; WATER;
D O I
10.1016/j.snb.2009.08.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L-1 KNO3 with pH adjusted to 2.25 with HNO3, an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L-1 KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L-1 with a detection limit of 1.00 x 10(-8) mol L-1. The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [21] Differential Pulse Anodic Stripping Voltammetry Determination of Lead(II) and Cadmium(II) with Multiwalled Carbon Nanotubes-Thiol Functionalized Chitosan Modified Bismuth Film Electrode
    Guo, Yan
    Ma, Yan
    Gao, Guizhi
    Li, Jun
    Xu, Jianqiang
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (01) : 113 - 118
  • [22] CARBON PASTE ELECTRODE MODIFIED WITH ORGANOFUNCTIONALIZED MESOPOROUS SILICA FOR ELECTROCHEMICAL DETECTION AND DETERMINATION OF COPPER(II) USING CYCLIC VOLTAMMETRY AND ANODIC STRIPPING VOLTAMMETRY
    Popa, Dana Elena
    Buleandra, Mihaela
    Mureseanu, Mihaela
    Ionica, Marcel
    Tanase, Ion Gh.
    REVUE ROUMAINE DE CHIMIE, 2010, 55 (02) : 123 - +
  • [23] Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode
    Deng, Pei-Hong
    Fei, Jun-Jie
    Feng, Yong-Lan
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 214 - 220
  • [24] Determination of Nanomolar Mercury(II) Concentration by Anodic-Stripping Voltammetry at a Carbon Paste Electrode Modified with Functionalized Nanoporous Silica Gel
    Javanbakht, Mehran
    Khoshsafar, Hamid
    Ganjali, Mohammad R.
    Badiei, Alireza
    Norouzi, Parviz
    Hasheminasab, Abed
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (01) : 35 - 41
  • [25] A stripping voltammetric method for Iodine Ion at chitosan incorporating carbon nanotubes modified electrode
    Wang, ZongHua
    Wang, YuFeng
    Zhang, FeiFei
    Xia, YanZhi
    Xia, JianFei
    ADVANCED RESEARCH ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2012, 600 : 166 - +
  • [26] Anodic stripping voltammetric determination of Hg(II) using poly xylenol orange film modified electrode
    Manikandan, Ramalingam
    Deepa, P. N.
    Narayanan, Sangilimuthu Sriman
    IONICS, 2019, 25 (03) : 1387 - 1394
  • [27] Anodic stripping voltammetric determination of Hg(II) using poly xylenol orange film modified electrode
    Ramalingam Manikandan
    P. N. Deepa
    Sangilimuthu Sriman Narayanan
    Ionics, 2019, 25 : 1387 - 1394
  • [28] Anodic stripping voltammetry of silver(I) using a carbon paste electrode modified with multi-walled carbon nanotubes
    Jahandari, Shokoofe
    Taher, Mohammad Ali
    Fazelirad, Hamid
    Sheikhshoai, Iran
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 347 - 354
  • [29] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Gabriela Roa
    M. T. Ramírez-Silva
    M. A. Romero-Romo
    Laura Galicia
    Analytical and Bioanalytical Chemistry, 2003, 377 : 763 - 769
  • [30] Anodic stripping voltammetry of silver(I) using a carbon paste electrode modified with multi-walled carbon nanotubes
    Shokoofe Jahandari
    Mohammad Ali Taher
    Hamid Fazelirad
    Iran Sheikhshoai
    Microchimica Acta, 2013, 180 : 347 - 354