Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan

被引:160
|
作者
Janegitz, Bruno C. [1 ]
Marcolino-Junior, Luiz H. [2 ]
Campana-Filho, Sergio P. [3 ]
Faria, Ronaldo C. [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-80060000 Curitiba, PR, Brazil
[3] Univ Sao Paulo, Inst Quim Sao Carlos, BR-05508 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbon nanotubes; Crosslinked chitosan; Copper determination; Anodic stripping voltammetry; ION ADSORPTION; AQUEOUS-SOLUTION; HEAVY-METALS; REACTIVE DYE; HG(II) IONS; MEMBRANES; LINKING; CHITIN; BEADS; WATER;
D O I
10.1016/j.snb.2009.08.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L-1 KNO3 with pH adjusted to 2.25 with HNO3, an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L-1 KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L-1 with a detection limit of 1.00 x 10(-8) mol L-1. The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [21] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Institute of Geonics, Academy of, Sciences of Czech Republic,, Studertska 1768, 708 00 Ostrava, Czech Republic
    Fresenius J Anal Chem, 5-6 (692-695):
  • [22] Simultaneous Anodic Stripping Voltammetric Determination of Lead and Cadmium with a Carbon Paste Electrode Modified by Tributyl Phosphate
    Huang, Sha-Sheng
    Cheng, Yi-Da
    Li, Bi-Fen
    Liu, Guo-Dong
    Mikrochimica Acta, 1998, 130 (01): : 97 - 101
  • [23] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Huang, SS
    Cheng, YD
    Li, BF
    Liu, GD
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 97 - 101
  • [24] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Sha-Sheng Huang
    Yi-Da Cheng
    Bi-Fen Li
    Guo-Dong Liu
    Microchimica Acta, 1998, 130 : 97 - 101
  • [25] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    Xiuhui He
    Li Chen
    Xuan Xie
    Zhaohong Su
    Cong Qin
    Ying Liu
    Ming Ma
    Shouzhuo Yao
    Le Deng
    Qingji Xie
    Yun Tian
    Dilan Qin
    Yueping Luo
    Microchimica Acta, 2012, 176 : 81 - 89
  • [26] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    He, Xiuhui
    Chen, Li
    Xie, Xuan
    Su, Zhaohong
    Qin, Cong
    Liu, Ying
    Ma, Ming
    Yao, Shouzhuo
    Deng, Le
    Xie, Qingji
    Tian, Yun
    Qin, Dilan
    Luo, Yueping
    MICROCHIMICA ACTA, 2012, 176 (1-2) : 81 - 89
  • [27] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [28] Voltammetric Determination of Nimesulide Using Multiwalled Carbon Nanotubes Modified Carbon Paste Electrode
    Agin, Fatma
    Serdaroglu, Vildan
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 13 (03) : 335 - 341
  • [29] Adsorptive Stripping Voltammetric Determination of Cobalt (II) on the Carbon Paste Electrode
    Mohadesi, Alireza
    Teimoori, Elham
    Taher, Mohammad Ali
    Beitollah, Hadis
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (02): : 301 - 308
  • [30] Differential pulse anodic stripping voltammetric determination of copper(II) with N-phenylcinnamohydroxamic acid modified carbon paste electrodes
    Alemu, H
    Chandravanshi, BS
    ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) : 165 - 173