Optimal sizing of array and inverter for grid-connected photovoltaic systems

被引:122
作者
Mondol, Jayanta Deb [1 ]
Yohanis, Yigzaw G.
Norton, Brian
机构
[1] Univ Ulster, Sch Built Environm, Newtownabbey BT37 0QB, North Ireland
[2] Dublin Inst Technol, Dublin, Ireland
关键词
grid-connected photovoltaics; TRNSYS; PV/inverter sizing ratio; orientation and inclination; performance ratio;
D O I
10.1016/j.solener.2006.01.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Optimum PV/inverter sizing ratios for grid-connected PV systems in selected European locations were determined in terms of total system output, system output per specific cost of a system, system output per annualised specific cost of a system, PV surface orientation, inclination, tracking system, inverter characteristics, insolation and PV/inverter cost ratio. Maximum total system output was determined for horizontal, vertical and 45 degrees inclined surfaces for a low efficiency inverter for sizing ratios of 1.5, 1.8 and 1.3, respectively; and for a medium efficiency inverter with sizing ratios of 1.4, 1.5 and 1.2. PV surface orientation and inclination have little impact on the performance of a high efficiency inverter. For different PV tracking systems and for different inverter characteristics, the optimum sizing ratio varied from 1.1 to 1.3. The PV/inverter cost ratio and the PV and inverter lifetimes have significant impact on the optimum PV/inverter sizing ratio. A correlation relating optimum sizing ratio and PV/inverter cost ratio has been developed; the correlation coefficients were found to be functions of insolation and inverter type. The impact of PV/inverter sizing ratio on PV array performance was less when PV array has a much higher cost than the inverter. The optimum sizing ratio for PV/inverter cost ratio of 6 and low efficiency inverter system varied from 1.4 to 1.2 for low to high insolation sites. For a high efficiency inverter system, the corresponding variation was from 1.3 to 1.1. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1517 / 1539
页数:23
相关论文
共 22 条
[1]   Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperature [J].
Burger, B ;
Rüther, R .
SOLAR ENERGY, 2006, 80 (01) :32-45
[2]  
Coppye W., 1995, 13 EUR PHOT SOL EN C, P1881
[3]  
Decker B., 1992, PROC 12 EPSEC, P1497
[4]  
JANTSCH M, 1992, 11 EUR PHOT SOL EN C, P1589
[5]   OPTIMIZING THE PANEL AREA OF A PHOTOVOLTAIC SYSTEM IN RELATION TO THE STATIC INVERTER - PRACTICAL RESULTS [J].
KELLER, L ;
AFFOLTER, P .
SOLAR ENERGY, 1995, 55 (01) :1-7
[6]  
KELLER L, 1992, 11 EUR PHOT SOL EN C, P1159
[7]  
KIL AJ, 1994, IEEE PHOT SPEC CONF, P1028, DOI 10.1109/WCPEC.1994.520136
[8]  
KLEIN SA, 2000, TRNSYS TRANSIENT SYS
[9]  
Liu B., 1962, ASHRAE Transactions, P526
[10]  
LOUCHE A, 1994, 12 EUR PHOT SOL EN C, P1638