Adsorption of MS2 bacteriophage on ultrafiltration membrane laboratory equipments

被引:15
作者
Pierre, Gwenaelle [1 ]
Causserand, Christel [1 ]
Roques, Christine [2 ]
Aimar, Pierre [1 ]
机构
[1] Univ Toulouse 3, Lab Genie Chim, UMR 5503, F-31062 Toulouse 09, France
[2] Univ Toulouse 3, Equipe Adhes Bacterienne & Format Biofilms, EA 3036, IFR 31, F-31062 Toulouse 09, France
关键词
Adsorption; MS2; bacteriophage; Membrane; Glass; Steel; REMOVAL; AGGREGATION; VIRUSES; WATER;
D O I
10.1016/j.desal.2008.11.037
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Virus adsorption has been quantified (i) on different materials including various containers made of glass, plastic or stainless steel and hollow fiber membranes made of polyethersulfone, polysulfone, PVDF or cellulose acetate (with two configurations: in/out and out/in and various molecular weight cut-offs); and (ii) on the filtration equipment. The selected virus is MS2 bacteriophage used as a model to estimate viral survival in water or to quantify virus elimination by membrane filtration. A series of experiments have been conducted with suspensions of MS2 at different concentrations prepared in a sterilized saline solution (8 g/L of KCl) or in sterilized distilled water. This Study has shown that the most appropriate material to be used as a filtration test tank is Pyrex glass. We show that an addition of a virus solution 15 min after the beginning of the experiment allows keeping the virus concentration at a high level in the system (including tank, tubing, and pump). No adsorption was observed on membrane materials tested during soaking. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:762 / 766
页数:5
相关论文
共 9 条
[1]   Effect of transmembrane pressure on rejection of viruses by ultrafiltration membranes [J].
Arkhangelsky, Elizabeth ;
Gitis, Vitaly .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 62 (03) :619-628
[2]   Development of a viral concentration method for bottled water stored in hydrophobic support [J].
Gassilloud, B. ;
Huguet, L. ;
Maul, A. ;
Gantzer, C. .
JOURNAL OF VIROLOGICAL METHODS, 2007, 142 (1-2) :98-104
[3]   Adhesion-aggregation and inactivation of Poliovirus 1 in groundwater stored in a hydrophobic container [J].
Gassilloud, B ;
Gantzer, C .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (02) :912-920
[4]  
Herath G, 1999, WATER SCI TECHNOL, V40, P331, DOI 10.2166/wst.1999.0607
[5]   Removal of MS2 bacteriophage using membrane technologies [J].
Hu, JY ;
Ong, SL ;
Song, LF ;
Feng, YY ;
Liu, WT ;
Tan, TW ;
Lee, LY ;
Ng, WJ .
WATER SCIENCE AND TECHNOLOGY, 2003, 47 (12) :163-168
[6]  
LANGLET J, 2007, J APPL MICROBIOL, P1364
[7]   Aggregation and surface properties of F-specific RNA phages: Implication for membrane filtration processes [J].
Langlet, Jeremie ;
Gaboriaud, Fabien ;
Duval, Jerome F. L. ;
Gantzer, Christophe .
WATER RESEARCH, 2008, 42 (10-11) :2769-2777
[8]   Occurrence and densities of bacteriophages proposed as indicators and bacterial indicators in river waters from Europe and South America [J].
Lucena, F ;
Méndez, X ;
Morón, A ;
Calderón, E ;
Campos, C ;
Guerrero, A ;
Cárdenas, M ;
Gantzer, C ;
Shwartzbrood, L ;
Skraber, S ;
Jofre, J .
JOURNAL OF APPLIED MICROBIOLOGY, 2003, 94 (05) :808-815
[9]   VIRUS REMOVAL FROM WATER AND WASTE-WATER USING MEMBRANES [J].
MADAENI, SS ;
FANE, AG ;
GROHMANN, GS .
JOURNAL OF MEMBRANE SCIENCE, 1995, 102 :65-75