Preoperative CT simulation of iliosacral screws for treating unstable posterior pelvic ring injury

被引:4
作者
Zhao, Peishuai [1 ]
Wang, Xiaopan [1 ]
Chen, Xiaotian [1 ]
Guan, Jianzhong [1 ]
Wu, Min [1 ]
机构
[1] Bengbu Med Coll, Affifiliated Hosp 1, Dept Orthopaed, Bengbu, Peoples R China
关键词
Pelvic injury; Computed tomography; Iliosacral screws; Preoperative planning; SACRAL MORPHOLOGY; INTERNAL-FIXATION; NAVIGATION; FLUOROSCOPY; PLACEMENT; FRACTURES; DISLOCATION; REDUCTION;
D O I
10.1186/s12891-022-05155-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The percutaneous iliosacral screw is a common procedure for treating pelvic posterior ring instability. Traditional X-ray fluoroscopy screw placement has the advantages of decreased bleeding and trauma, but it also has some drawbacks, such as increased radiation exposure and screw dislocation. The purpose of this study was to establish a safe, effective, and quick approach for putting iliosacral screws for the treatment of unstable posterior pelvic ring damage utilizing simulated screws based on preoperative computed tomography (CT) planning. Methods From February 2019 to June 2020, we retrospectively assessed 41 patients with posterior pelvic ring instability who were treated with percutaneous iliosacral screws in our institution, and randomly separated them into two groups: conventional surgery (n = 20) and preoperative planning (n = 21). Pelvic radiographs (anteroposterior, inlet, outlet), as well as normal CT scans of the pelvis, were all taken postoperatively to confirm the screw position. After that, the screw insertion time, the radiation exposure time, and the screw misplacement rate (as assessed by postoperative CT) were all examined. Screw position grading was evaluated by Smith grading. Results In the conventional surgery group, 26 screws were inserted in 20 patients, with each screw insertion taking 23.15 +/- 4.19 min and 1.02 +/- 0.17 min to expose to radiation. Eight of the 26 screws were misplaced (30.8%). In the preoperative planning group, 24 screws were inserted in 21 patients, with each screw taking 19.57 +/- 4.05 min to implant and 0.67 +/- 0.09 min to expose to radiation. One of 24 screws was misplaced (4.2%). Screw insertion time, radiation exposure time, and screw dislocation rate were all significantly reduced when preoperative planning aided iliosacral screw placement (P < 0.05). Conclusions Preoperative CT simulation of iliosacral screws for placement planning, screw trajectory, and intraoperative screw placement is a safe way for reducing surgical time, radiation exposure, and ensuring accurate screw placement.
引用
收藏
页数:9
相关论文
共 34 条
[1]   Osseous fixation pathways in pelvic and acetabular fracture surgery: Osteology, radiology, and clinical applications [J].
Bishop, Julius A. ;
Routt, Milton Lee , Jr. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (06) :1502-1509
[2]   CT guided percutaneous fixation of sacroiliac fractures in trauma patients [J].
Blake-Toker, AM ;
Hawkins, L ;
Nadalo, L ;
Howard, D ;
Arazoza, A ;
Koonsman, M ;
Dunn, E .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (06) :1117-1121
[3]  
Ciolli Gianluca, 2021, Med Glas (Zenica), V18, P309, DOI 10.17392/1326-21
[4]  
Ebraheim N A, 1987, J Orthop Trauma, V1, P197, DOI 10.1097/00005131-198701030-00001
[5]   Retrieval of broken iliosacral screws: The power of a push screw [J].
El Dafrawy, Mostafa H. ;
Osgood, Greg M. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (07) :1411-1416
[6]   Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions [J].
Elzohairy, M. M. ;
Salama, A. M. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) :223-227
[7]   A simple approach for the preoperative assessment of sacral morphology for percutaneous SI screw fixation [J].
Goetzen, Michael ;
Ortner, Kevin ;
Lindtner, Richard A. ;
Schmid, Rene ;
Blauth, Michael ;
Krappinger, Dietmar .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (09) :1251-1257
[8]   2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series [J].
Gras, Florian ;
Marintschev, Ivan ;
Wilharm, Arne ;
Klos, Kajetan ;
Mueckley, Thomas ;
Hofmann, Gunther O. .
BMC MUSCULOSKELETAL DISORDERS, 2010, 11
[9]   Iliosacral Screw Placement: Are Uniplanar Changes Realistic Based on Standard Fluoroscopic Imaging? [J].
Graves, Matt L. ;
Routt, M. L. Chip, Jr. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (01) :204-208
[10]   Simple mathematical model of sacroiliac screws safe-zoneEasy to implement by pelvic inlet and outlet views [J].
Herman, Amir ;
Keener, Emily ;
Dubose, Candice ;
Lowe, Jason A. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (07) :1478-1484