Microwave-supported preparation of 68Ga bioconjugates with high specific radioactivity

被引:169
作者
Velikyan, I
Beyer, GJ
Långström, B
机构
[1] Uppsala Imanet AB, SE-75109 Uppsala, Sweden
[2] Univ Uppsala, Inst Chem, Dept Organ Chem, BMC, SE-75124 Uppsala, Sweden
[3] Univ Hosp Geneva, Cyclotron Unit, CH-1211 Geneva, Switzerland
关键词
D O I
10.1021/bc030078f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The generator-produced positron-emitting Ga-68 (T-1/2 = 68 min) is of potential interest for clinical PET. Ga-68 as a metallic cation is suitable for complexation reactions with chelators, naked or conjugated, with peptides or other macromolecules. Large Ga-68 generator eluate volumes, metal traces from the generator column material, or reaction reagents, however, disturb a fast, reliable, and quantitative labeling procedure. In this paper we describe a simple technique, based on anion exchange, aiming first, to increase the Ga-68 concentration, second to purify it from competing impurities, and third to obtain a fast and quantitative Ga-68-labeled peptide conjugate that can be applied in humans without further purification. Within 5 min one can obtain from the original 6 mL generator eluate a 200 muL Ga-68 preparation (volume reduction by a factor 30) that is suitable for direct and quantitative labeling of peptide conjugates. DOTATOC (DOTA-D-Phe(1)-Tyr(3)-octreotide, DOTA = 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) was used as a test tracer for comparing the labeling properties of the different Ga-68 preparations. In combination with microwave heating, peptide conjugates of 0.5-1 nmol quantities could be labeled within 10 min with the full Ga-68 activity of a generator. Further purification of the Ga-68-labeled peptide conjugate was no longer required since the nuclide incorporation was quantitative. The specific radioactivity (with respect to the peptide) was improved by a factor similar to100 compared to the previously applied techniques using the original generator eluate. The commercial Ge-68/Ga-68 generator from Obninsk in combination with this system for purification and concentration with an integrated microwave-supported labeling technology resulted in a kitlike technology for Ga-68-tracer production. The first automated prototype using this technology is being tested.
引用
收藏
页码:554 / 560
页数:7
相关论文
共 9 条
[1]   Microwave-enhanced radiochemistry [J].
Elander, N ;
Jones, JR ;
Lu, SY ;
Stone-Elander, S .
CHEMICAL SOCIETY REVIEWS, 2000, 29 (04) :239-249
[2]  
GREEN MA, 1989, NUCL MED BIOL, V16, P435
[3]  
KRAUS KA, 1956, C PEAC US AT EN UN, P113
[4]   Separation of 68Ga from 68Ge using a macroporous organic polymer containing N-methylglucamine groups [J].
Nakayama, M ;
Haratake, M ;
Koiso, T ;
Ishibashi, O ;
Harada, K ;
Nakayama, H ;
Sugii, A ;
Yahara, S ;
Arano, Y .
ANALYTICA CHIMICA ACTA, 2002, 453 (01) :135-141
[5]  
NEIRINCKX RD, 1981, Patent No. 4264468
[6]  
OHLSSON T, 1974, Journal of Microwave Power, V9, P129
[7]  
ROSC F, 2002, HDB NUCL RADIOCHEMIS, P1
[8]   A NEW GE-68-GA-68 RADIOISOTOPE GENERATOR SYSTEM FOR PRODUCTION OF GA-68 IN DILUTE HCL [J].
SCHUHMACHER, J ;
MAIERBORST, W .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1981, 32 (01) :31-36
[9]   Microwave accelerated 68Ga-labelling of oligonucleotides [J].
Velikyan, I ;
Lendvai, G ;
Välilä, M ;
Roivainen, A ;
Yngve, U ;
Bergström, M ;
Långström, B .
JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2004, 47 (01) :79-89