Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression

被引:32
作者
Lu, ZQ [1 ]
Liu, Y [1 ]
Barreto, V [1 ]
Pohl, C [1 ]
Avdalovic, N [1 ]
Joyce, R [1 ]
Newton, B [1 ]
机构
[1] Dionex Chem Corp, Res & Dev, Sunnyvale, CA 94088 USA
关键词
water analysis; inorganic anions; organic acids;
D O I
10.1016/S0021-9673(02)00143-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-mug/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line electrolytic eluent generator and detected using the suppressed conductivity detection method. The method performance was evaluated by analyzing synthetic water samples containing additives encountered in the power plant water samples and four water samples from a fossil fuel power plant. The relative standard deviations of retention times of analyte ions separated on the hydroxide-selective anion-exchange column were less than 0.4%. The recoveries of analyte ions spiked into the synthetic water samples at concentrations of 0.13-1.0 mug/l were in the range of 70-120%. The method detection limits for analyte ions in deionized water were 0.0099, 0.0056, 0.019, 0.057, 0.0084, 0.023, 0.067, 0.037, and 0.079 mug/l for fluoride, acetate, formate, chloride, nitrite, sulfate, bromide, nitrate, and phosphate, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 19 条
  • [1] [Anonymous], 1993, TR102134 EPRI
  • [2] ONLINE APPLICATION OF ION CHROMATOGRAPHY IN A THERMAL POWER-PLANT
    BALCONI, L
    PASCALI, R
    SIGON, F
    [J]. ANALYTICA CHIMICA ACTA, 1986, 179 : 419 - 425
  • [3] QUALITATIVE CORROSION MONITORING BY ONLINE ION CHROMATOGRAPHY
    BOSTIC, D
    BURNS, G
    HARVEY, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2): : 163 - 171
  • [4] *DION, 2001, DION PROD INF B
  • [5] *DION, 2001, 142 DION
  • [6] *EPRI, 1984, RAT CHEM CONTR FEEDW, V1
  • [7] *EPRI, 1991, MON CYCL WAT CHEM FO, V3
  • [8] RECENT ADVANCES IN THE SIMULTANEOUS DETERMINATION OF ANIONS AND SILICA IN HIGH-PURITY WATER
    HARVEY, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2): : 209 - 220
  • [9] HASCHKE C, 1990, LC GC, V8, P870
  • [10] Improved method for the determination of trace perchlorate in ground and drinking waters by ion chromatography
    Jackson, PE
    Gokhale, S
    Streib, T
    Rohrer, JS
    Pohl, CA