摘要
Background: Despite the importance of nitric oxide (NO) in vascular physiology and pathology, a high-throughput method for the quantification of its vascular generation is lacking. Objective: By using the fluorescent probe 4-amino-5-methylamino-2,7-difluorofluorescein (DAF-FM), we have optimized a simple method for the determination of the generation of endothelial nitric oxide in a microplate format. Methods: A nitric oxide donor was used (3-morpholinosydnonimine hydrochloride, SIN-1). Different factors affecting the method were studied, such as the effects of dye concentration, different buffers, time of reaction, gain, and number of flashes. Results: Beer's law was linear over a nanomolar range (1-10 nM) of SIN-1 with wavelengths of maximum excitation and emission at 495 and 525 nm; the limit of detection reached 0.897 nM. Under the optimized conditions, the generation of rat aortic endothelial NO was measured by incubating DAF-FM with serial concentrations (10-1000 mu M) of acetylcholine (ACh) for 3 min. To confirm specificity, N-omega-Nitro-l-arginine methyl ester (l-NAME)the standard inhibitor of endothelial NO synthasewas found to inhibit the ACh-stimulated generation of NO. In addition, vessels pre-exposed for 1 h to 400 mu M of the endothelial damaging agent methyl glyoxal showed inhibited NO generation when compared to the control stimulated by ACh. Conclusions: The capability of the method to measure micro-volume samples makes it convenient for the simultaneous handling of a very large number of samples. Additionally, it allows samples to be run simultaneously with their replicates to ensure identical experimental conditions, thus minimizing the effect of biological variability.
引用
收藏
页数:9
相关论文
共 25 条
[1]   Electrochemical assay for the determination of nitric oxide metabolites using copper(II) chlorophyllin modified screen printed electrodes [J].
Balamurugan, Murugesan ;
Madasamy, Thangamuthu ;
Pandiaraj, Manickam ;
Bhargava, Kalpana ;
Sethy, Niroj Kumar ;
Karunakaran, Chandran .
ANALYTICAL BIOCHEMISTRY, 2015, 478 :121-127
[2]   Simultaneous determination of sildenafil citrate and some nitric oxide releasing drugs in human plasma using UPLC MS/MS [J].
El-Bagary, Ramzia ;
Azzazy, Hassan M. E. ;
ElKady, Ehab F. ;
Farouk, Faten .
CLINICAL BIOCHEMISTRY, 2014, 47 (7-8) :654-656
[3]  
FEELISCH M, 1989, J CARDIOVASC PHARM, V14, pS13, DOI 10.1097/00005344-198914110-00004
[4]  
Govantes C, 1996, METHOD FIND EXP CLIN, V18, P387
[5]   PRODUCTION OF HYDROXYL RADICALS FROM THE SIMULTANEOUS GENERATION OF SUPEROXIDE AND NITRIC-OXIDE [J].
HOGG, N ;
DARLEYUSMAR, VM ;
WILSON, MT ;
MONCADA, S .
BIOCHEMICAL JOURNAL, 1992, 281 :419-424
[6]  
Jain P, 2016, METHODS MOL BIOL, V1424, P69, DOI 10.1007/978-1-4939-3600-7_7
[7]   DETECTION OF NITRIC-OXIDE PRODUCTION FROM A PERFUSED ORGAN BY A LUMINOL-H2O2 SYSTEM [J].
KIKUCHI, K ;
NAGANO, T ;
HAYAKAWA, H ;
HIRATA, Y ;
HIROBE, M .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1794-1799
[8]  
Kojima H, 1999, ANGEW CHEM INT EDIT, V38, P3209, DOI 10.1002/(SICI)1521-3773(19991102)38:21<3209::AID-ANIE3209>3.0.CO
[9]  
2-6
[10]   Detection and imaging of nitric oxide with novel fluorescent indicators: Diaminofluoresceins [J].
Kojima, H ;
Nakatsubo, N ;
Kikuchi, K ;
Kawahara, S ;
Kirino, Y ;
Nagoshi, H ;
Hirata, Y ;
Nagano, T .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2446-2453