Copper(H)e-selective potentiometric sensors based on porphyrins in PVC matrix

被引:391
作者
Gupta, V. K. [1 ]
Jain, A. K.
Maheshwari, G.
Lang, Heinrich
Ishtaiwi, Z.
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Tech Univ Chemnitz, Fak Nat Wissensch, Inst Chem, Lehrstuhl Anorgan Chem, D-09111 Chemnitz, Germany
关键词
polyvinyl chloride; Nernstian slope; copper selective electrode; porphyrins;
D O I
10.1016/j.snb.2005.11.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cu2+ selective sensors have been fabricated from polyvinyl chloride (PVC) matrix membranes containing neutral carrier porphyrin (A and B) ionophores. The addition of sodium tetraphenylborate and the plasticizer DOP has been found to substantially improve the performance of the sensors. The membranes of various compositions of the two porphyrins were investigated and it was found that the best performance was obtained for the membrane of composition B:PVC:NaTPB:DOP in the ratio 5:150:2:150. The sensor shows a linear potential response for Cu2+ over a wide concentration range 4.4 x 10(-6) to 1.0 x 10(-1) M with Nernstian compliance (29.3 mV decade(-1) of activity) between pH 2.8 and 7.9 and a fast response time of similar to 8 s. The potentiometric selectivity coefficient values as determined by fixed interference method indicate excellent selectivity for CU2+ ions over interfering cations. The sensor exhibits adequate shelf life (similar to 4 months) with good reproducibility (standard deviation +/- 0.2 mV). The sensor can also be used in partially non-aqueous media having up to 20% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. The sensor has been used in the potentiometric titration of Cu2+ with EDTA. The utility of the sensor has been tested by determining copper in vegetable foliar and swimming pool water sample successfully. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 40 条
[1]   Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection on-line derivatization and preconcentration [J].
Ali, A ;
Shen, H ;
Yin, XF .
ANALYTICA CHIMICA ACTA, 1998, 369 (03) :215-223
[2]  
[Anonymous], 1983, Statistical methods
[3]  
BRZOZKA Z, 1990, CHEM ANAL-WARSAW, V35, P415
[4]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582
[5]   Response of the jalpaite membrane copper(II) ion-selective electrode in marine waters [J].
DeMarco, R ;
Mackey, DJ ;
Zirino, A .
ELECTROANALYSIS, 1997, 9 (04) :330-334
[6]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[7]   Copper-selective PVC membrane electrodes based on salens as carriers [J].
Fakhari, AR ;
Raji, TA ;
Naeimi, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) :317-323
[8]  
Fries J., 1977, ORGANIC REAGENTS TRA
[9]   Copper(II) ion-selective electrodes based on dithiosalicylic and thiosalicylic acids [J].
Gismera, MJ ;
Procopio, JR ;
Sevilla, MT ;
Hernández, L .
ELECTROANALYSIS, 2003, 15 (02) :126-132
[10]  
Gismera MJ, 1999, ANAL CHIM ACTA, V385, P143