Cyclam-Functionalized Silica-Modified Electrodes for Selective Determination of Cu(II)

被引:25
作者
Goubert-Renaudin, Stephanie [1 ]
Etienne, Mathieu [1 ]
Rousselin, Yoann [2 ]
Denat, Franck [2 ]
Lebeau, Benedicte [3 ]
Walcarius, Alain [1 ]
机构
[1] Nancy Univ, CNRS, Lab Chim Phys & Microbiol Environm, UMR 7564, F-54600 Villers Les Nancy, France
[2] Univ Bourgogne, CNRS, Inst Chim Mol, UMR5260, F-21078 Dijon, France
[3] UHA, ENSCMu, CNRS, Lab Mat Porosite Controlee,UMR 7016, F-68093 Mulhouse, France
关键词
Mesoporous silica; Cyclam; Carbon paste electrode; Copper; Voltammetry; CARBON-PASTE ELECTRODE; ORGANICALLY MODIFIED SILICATES; MESOPOROUS SILICA; VOLTAMMETRIC ANALYSIS; BINDING-SITES; TRACE-METALS; COPPER(II); COMPLEXES; MERCURY; ACCESS;
D O I
10.1002/elan.200804378
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclam derivatives have been grafted via 1, 2 or 4 silylated arms to the surface of mesoporous silica and the resulting materials have been incorporated into carbon paste electrodes and applied to the preconcentration electroanalysis of Cu(II). Sensitive and selective detection of the target analyte was achieved owing to the attractive binding properties of this macrocyclic ligand towards Cu(II) species. Various parameters likely to affect the preconcentration and detection steps have been studied, including pH of the accumulation medium, composition of the detection solution, structure and composition of the adsorbent, accumulation time, or presence of potentially interfering species. In particular, the effect of the number of silylated groups linking the macrocycle to the silica network on the sensor performance was discussed. After optimization, Cu(II) can be determined in a linear concentration range extending from 2 nM to 100 mu M. The method was validated by reliable Cu(II) determination in tap water.
引用
收藏
页码:280 / 289
页数:10
相关论文
共 49 条
[1]   CHEMICALLY MODIFIED ELECTRODE FOR THE SIMULTANEOUS DETERMINATION OF TRACE-METALS AND SPECIATION ANALYSIS [J].
AGRAZ, R ;
SEVILLA, MT ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :205-212
[2]   VOLTAMMETRIC DETERMINATION OF TRACE-METALS AND ORGANICS AFTER ACCUMULATION AT MODIFIED ELECTRODES [J].
ARRIGAN, DWM .
ANALYST, 1994, 119 (09) :1953-1966
[3]   Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions [J].
Cesarino, Ivana ;
Marino, Glimaldo ;
do Rosario Matos, Jivaldo ;
Gomes Cavalheiro, Eder Tadeu .
TALANTA, 2008, 75 (01) :15-21
[4]   Analytical applications of organically modified silicates [J].
Collinson, MM .
MIKROCHIMICA ACTA, 1998, 129 (3-4) :149-165
[5]   Synthesis, characterization, and X-ray crystal structures of cyclam derivatives. 8. Thermodynamic and kinetic appraisal of lead(II) chelation by octadentate carbamoyl-armed macrocycles [J].
Cuenot, F ;
Meyer, M ;
Espinosa, E ;
Guilard, R .
INORGANIC CHEMISTRY, 2005, 44 (22) :7895-7910
[6]   Cyclam complexes containing silica gels for dioxygen adsorption [J].
Dubois, G ;
Tripier, R ;
Branès, SP ;
Denat, F ;
Guilard, R .
JOURNAL OF MATERIALS CHEMISTRY, 2002, 12 (08) :2255-2261
[7]  
Dubois G, 2001, ANGEW CHEM INT EDIT, V40, P1087, DOI 10.1002/1521-3773(20010316)40:6<1087::AID-ANIE10870>3.0.CO
[8]  
2-O
[9]   First organic-inorganic hybrid materials with controlled porosity incorporating cyclam units [J].
Dubois, G ;
Corriu, RJP ;
Reyé, C ;
Brandès, S ;
Denat, F ;
Guilard, R .
CHEMICAL COMMUNICATIONS, 1999, (22) :2283-2284
[10]   Kinetics and mechanism of metal complex formation with N4-donor macrocycles of the cyclam type [J].
Elias, H .
COORDINATION CHEMISTRY REVIEWS, 1999, 187 :37-73