A Novel Deadbeat Control for Three-Phase Grid-Connected VSI with an Output LCL Filter in Natural Frame

被引:0
作者
Seyedalipour, S. Sajjad [1 ]
机构
[1] KN Toosi Univ Technol, Fac Elect Engn, Tehran, Iran
来源
34TH INTERNATIONAL POWER SYSTEM CONFERENCE (PSC2019) | 2019年
关键词
Voltage source inverter; deadbeat control; grid-connected inverter; PREDICTIVE CURRENT CONTROL; LYAPUNOV-FUNCTION; CONTROL STRATEGY;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A voltage source inverter (VSI) is a common solution in order to integrate distributed generation resources to utility grid. In this paper, by considering an LCL filter at the output of the three-phase grid-connected VSI, the system model is attained in the natural frame. Then, according to the achieved model, a novel deadbeat control is suggested to supply sinusoidal currents for being injected to the utility grid. Moreover, the considered method does not need transforming the system equations from the abc frame to another. The performance and feasibility of the suggested deadbeat control is evaluated in balanced, unbalanced and distorted grid conditions. The computer simulation results obtained from MATLAB/Simulink show that the suggested control demonstrates a good operation in reaching rapid dynamic response, closely zero steady-state error, closed-loop system global stability and also sinusoidal utility grid current including low total harmonic distortion (THD).
引用
收藏
页码:447 / 452
页数:6
相关论文
共 50 条
  • [41] Lyapunov-Based Digital Control of a Grid-Connected Inverter With an LCL Filter
    Kato, Toshiji
    Inoue, Kaoru
    Ueda, Masahiko
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (04) : 942 - 948
  • [42] A ZVS Grid-Connected Three-Phase Inverter
    Li, Rui
    Ma, Zhiyuan
    Xu, Dehong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (08) : 3595 - 3604
  • [43] Modelling of three-phase grid-connected inverters
    Smedley, Keyue
    Guiotto, Edoardo
    Vacher, Francois
    Jin, Taotao
    INTERNATIONAL JOURNAL OF GLOBAL ENERGY ISSUES, 2006, 26 (3-4) : 302 - 321
  • [44] Indirect Grid Current Control of LCL Filter based Grid-Connected Converter
    Mukherjee, Subhajyoti
    Shamsi, Pourya
    Ferdowsi, Mehdi
    Kimball, Jonathan
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 3024 - 3031
  • [45] Robust Control of Three-Phase VSI with LCL Filter for Distributed Generation Power Quality Improvement
    Ugaz Pena, Jose Carlos
    Sampaio, Leonardo Poltronieri
    Gomes de Brito, Moacyr Aureliano
    Canesin, Carlos Alberto
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2020, 31 (04) : 1051 - 1062
  • [46] HIL Co-Simulation of Proportional Resonant Sliding Mode control Based FPGA for a Three-Phase Grid-connected VSI System
    Mansouri, Houssam Eddine
    Talbi, Billel
    Mehiris, Moussa Abderrahim
    Messaoudene, Idris
    Krama, Abdelbasset
    PROGRAM OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, ICEEAC 2024, 2024,
  • [47] LCL Filter Design with the Inductor Nonlinear Behavior Consideration in the Three Phase Grid-Connected Inverter
    Liu, Yitao
    Jiang, Shiqi
    Wang, Huaizhi
    Wang, Guibin
    Peng, Jianchun
    Liu, Yong
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [48] Impedance modeling and characteristic analysis of three-phase LCL-type grid-connected inverters
    Li Y.
    Zhao S.
    Ma Y.
    Li R.
    Wang Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (07): : 107 - 113
  • [49] Exploring Inherent Damping Characteristic of LCL-Filters for Three-Phase Grid-Connected Voltage Source Inverters
    Tang, Yi
    Loh, Poh Chiang
    Wang, Peng
    Choo, Fook Hoong
    Gao, Feng
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 312 - 319
  • [50] A Multicell Network Control and Design for Three-Phase Grid-Connected Inverter
    Peng, Li
    Wu, Weibiao
    Hu, Ke
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (04) : 2740 - 2749