Preparation and evaluation of monolithic poly(N-vinylcarbazole-co-1,4-divinylbenzene) capillary columns for the separation of small molecules

被引:23
作者
Koeck, Rainer [1 ]
Fischnaller, Martin [1 ]
Bakry, Rania [1 ]
Tessadri, Richard [2 ]
Bonn, Guenther K. [1 ]
机构
[1] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
[2] Leopold Franzens Univ, Inst Mineral & Petrog, A-6020 Innsbruck, Austria
关键词
Monolith; Free radical polymerization; Reversed-phase chromatography; N-Vinylcarbazole; Liquid chromatography; PERFORMANCE LIQUID-CHROMATOGRAPHY; REVERSED-PHASE CHROMATOGRAPHY; ORGANIC MONOLITHS; N-VINYLCARBAZOLE; CONVECTIVE FLOW; POLYMER; DIVINYLBENZENE; EFFICIENCY; POLY(STYRENE-CO-DIVINYLBENZENE); KINETICS;
D O I
10.1007/s00216-014-8007-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Short-term polymerization or the so-called low-conversion polymerization was applied for the preparation of N-vinylcarbazole (NVC) and 1,4-divinylbenzene (DVB) monolithic capillary columns. The synthesis was carried out by thermally initiated free radical copolymerization under the influence of inert micro- (toluene) and macroporogen (1-decanol) and alpha,alpha'-azoisobutyronitrile (AIBN) as radical initiator. The morphological and porous properties were studied by scanning electron microscopy (SEM), nitrogen adsorption, and mercury intrusion porosimetry (MIP). The copolymerization process was studied by monomer conversion measurements. This approach led to increased porosity and specific surface area. A specific surface area above 400 m(2)/g of the monolith and a distinct bimodal pore size distribution were obtained. The chromatographic performance was determined in terms of theoretical plate heights and number of theoretical plates. The lowest plate height value was found to be 3.9 mu m (corresponding to a parts per thousand 256,000 plates per meter) applying methylparaben utilizing an 80 mm x 0.2 mm i.d. monolithic capillary. The developed NVC/DVB monolithic supports showed high separation efficiency towards small molecules, which was exemplified applying reversed-phase (RP) separation of alkylbenzenes, beta-blockers, flavanoids, parabens, and phenones. The loading capacity was analyzed for isocratic separation of seven alkylbenzenes and was found to be up to 77 ng total mass of alkylbenzenes. Furthermore, a long-term stability test of 1,000 consecutive runs was performed and resulted in a maximum variance of 0.97, 0.85, and 0.16 % RSD for resolution, peak width at half height, and retention times, respectively. The material was proven to have a high permeability of 1.11E-14 m(2), applying water as a mobile phase.
引用
收藏
页码:5897 / 5907
页数:11
相关论文
共 36 条
[1]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[2]   Preparation of macroporous methacrylate monolithic material with convective flow properties for bioseparation: Investigating the kinetics of pore formation and hydrodynamic performance [J].
Danquah, Michael K. ;
Forde, Gareth M. .
CHEMICAL ENGINEERING JOURNAL, 2008, 140 (1-3) :593-599
[3]  
Engelhardt H, 1997, LCGC, V17, P856
[4]   Poly(2-N-carbazolylethyl acrylate)-modified silica as a new polymeric stationary phase for reversed-phase high-performance liquid chromatography [J].
Gautam, Usha Ghimire ;
Sawada, Tsuyoshi ;
Gautam, Mani Prasad ;
Takafuji, Makoto ;
Ihara, Hirotaka .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) :7422-7426
[5]   Influence of the polymerisation time on the porous and chromatographic properties of monolithic poly(1,2-bis(p-vinylphenyl))ethane capillary columns [J].
Greiderer, Andreas ;
Trojer, Lukas ;
Huck, Christian W. ;
Bonn, Guenther K. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (45) :7747-7754
[6]   Monolithic poly(1,2-bis(p-vinylphenyl)ethane) capillary columns for simultaneous separation of low- and high-molecular-weight compounds [J].
Greiderer, Andreas ;
Ligon, S. Clark, Jr. ;
Huck, Christian W. ;
Bonn, Guenther K. .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) :2510-2520
[7]   Study of the mass transfer kinetics in a monolithic column [J].
Gritti, F ;
Piatkowski, W ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :51-71
[8]   The effect of different diluents on the formation of N-vinylcarbazole-divinylbenzene copolymer beads [J].
Hamid, MA ;
Naheed, R ;
Fuzail, M ;
Rehman, E .
EUROPEAN POLYMER JOURNAL, 1999, 35 (10) :1799-1811
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[10]   Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns [J].
Ivanov, AR ;
Zang, L ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5306-5316