Concentrations and stability of methyl methacrylate, glutaraldehyde, formaldehyde and nickel sulfate in commercial patch test allergen preparations

被引:12
作者
Siegel, Paul D. [1 ]
Fowler, Joseph F. [2 ]
Law, Brandon F. [1 ]
Warshaw, Erin M. [3 ]
Taylor, James S. [4 ]
机构
[1] NIOSH, Hlth Effects Lab Div, Allergy & Clin Immunol Branch, Morgantown, WV 26505 USA
[2] Univ Louisville, Div Dermatol, Louisville, KY 40202 USA
[3] Univ Minnesota, Minneapolis Vet Affairs Hlth Care Syst, Minneapolis, MN 55417 USA
[4] Cleveland Clin, Cleveland, OH 44195 USA
关键词
patch test allergens; nickel sulfate; formaldehyde; glutaraldehyde; concentration and stability; methyl methacrylate; DIPHENYLMETHANE DIISOCYANATE; PETROLATUM; DIPHENYLMETHANE-4,4'-DIISOCYANATE; SENSITIVITY; DEGRADATION;
D O I
10.1111/cod.12169
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background Epicutaneous patch tests are used to reproduce allergy and diagnose allergic contact dermatitis. Reliable allergen test preparations are required. Objectives The purpose of the present study was to measure the actual concentrations of nickel(II) sulfate hexahydrate (NiSO4), methyl methacrylate, formaldehyde, and glutaraldehyde, and to compare them with the labelled concentrations, in commercial patch test allergen preparations found in dermatology clinics where patch testing is routinely performed. Materials and methods The commercial in-date and out-of-date patch test allergen preparations concentrations of NiSO4, methyl methacrylate, formaldehyde and glutaraldehyde from one to three participating clinics were analysed with chromatographic or wet chemical techniques. Results NiSO4 and formaldehyde concentrations were at or above the labelled concentrations; however, formaldehyde loss occurred with storage. NiSO4 particulate was uniformly distributed throughout the petrolatum. 'In-use' methyl methacrylate reagent syringes all contained <= 56% of the 2% label concentration, with no observable relationship with expiration date. Lower methyl methacrylate cocentrations were consistently measured at the syringe tip end, suggesting loss resulting from methyl methacrylate's volatility. The concentrations of glutaraldehyde patch test allergen preparations ranged from 27% to 45% of the labelled (1% in pet.) concentration, independently of expiration date. Conclusions Some false-negative methyl methacrylate, formaldehyde or glutaraldehyde patch test results may be attributable to instability of the test preparations.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 20 条
[1]   Stability of thiuram disulfides in patch test preparations and formation of asymmetric disulfides [J].
Bergendorff, O ;
Hansson, C .
CONTACT DERMATITIS, 2001, 45 (03) :151-157
[2]   Towards a perfect vehicle(s) for diagnostic patch testing: an overview [J].
Chiang, Audris ;
Maibach, Howard I. .
CUTANEOUS AND OCULAR TOXICOLOGY, 2013, 32 (01) :60-66
[3]  
Dow Chemical Company, 2003, GLUT SAF HANDL STOR
[4]   Degradation of triglycidyl isocyanurate as a cause of false-negative patch test reaction [J].
Erikstam, U ;
Bruze, M ;
Goossens, A .
CONTACT DERMATITIS, 2001, 44 (01) :13-17
[5]   Poor correlation between stated and found concentrations of diphenylmethane-4,4′-diisocyanate (4,4′-MDI) in petrolatum patch-test preparations [J].
Frick, M ;
Zimerson, E ;
Karlsson, D ;
Marand, Å ;
Skarping, G ;
Isaksson, M ;
Bruze, M .
CONTACT DERMATITIS, 2004, 51 (02) :73-78
[6]   How to optimize patch testing with diphenylmethane diisocyanate [J].
Frick-Engfeldt, Malin ;
Isaksson, Marlene ;
Zimerson, Erik ;
Bruze, Magnus .
CONTACT DERMATITIS, 2007, 57 (03) :138-151
[7]   Is it possible to improve the patch-test diagnostics for isocyanates?: A stability study of petrolatum preparations of diphenylmethane-4,4′-diisocyanate and polymeric diphenylmethane diisocyanate [J].
Frick-Engfeldt, Malin ;
Zimerson, Erik ;
Karlsson, Daniel ;
Skarping, Gunnar ;
Isaksson, Marlene ;
Bruze, Magnus .
CONTACT DERMATITIS, 2007, 56 (01) :27-34
[8]   Correlation between Stated and Measured Concentrations of Acrylate and Methacrylate Allergens in Patch-Test Preparations [J].
Goon, Anthony Teik-Jin ;
Bruze, Magnus ;
Zimerson, Erik ;
Sorensen, Osten ;
Goh, Chee-Leok ;
Koh, David Soo-Quee ;
Isaksson, Marlene .
DERMATITIS, 2011, 22 (01) :27-32
[9]   Stability of patch test preparations of methyldibromo glutaronitrile in petrolatum [J].
Gruvberger, B ;
Bjerkemo, M ;
Bruze, M .
CONTACT DERMATITIS, 2004, 51 (5-6) :315-316
[10]   GLUTARALDEHYDE - PATCH TEST, VEHICLE AND CONCENTRATION [J].
HANSEN, EM ;
MENNE, T .
CONTACT DERMATITIS, 1990, 23 (05) :369-370