Transapical Transcatheter Aortic Valve Implantation Using the JenaValve: A One-Year Follow-up

被引:7
作者
Reuthebuch, Oliver [1 ]
Koechlin, Luca [1 ]
Kaufmann, Beat A. [2 ]
Kessel-Schaefer, Arnheid [2 ]
Gahl, Brigitta [3 ]
Eckstein, Friedrich S. [1 ]
机构
[1] Univ Basel Hosp, Dept Cardiac Surg, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Cardiol, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Dept Cardiovasc Surg, CH-4031 Basel, Switzerland
关键词
aortic valve and root; heart valve; transapical; TAVI; outcomes; SINGLE-CENTER EXPERIENCE; REGURGITATION; STENOSIS;
D O I
10.1055/s-0035-1552980
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Since the first transcatheter aortic valve implantation (TAVI) in 2002, TAVI technique has gained an increasing popularity especially in high-risk patients. In this study, we present the first echocardiographic midterm outcome with the second-generation transapical JenaValve TAVI system (JenaValve Technology GmbH, Munich, Germany) in patients with aortic stenosis (AS). Methods Between November 2011 and November 2012, a total of 28 patients received transapical TAVI using the JenaValve. Primary endpoint was a combined efficacy endpoint after 1year, which included all-cause mortality after more than 30 days, failure of current therapy for AS requiring hospitalization for symptoms of valve-related cardiac decompensation or prosthetic heart valve dysfunction. Moreover, we analyzed secondary endpoints after 3 and 12 months including cardiovascular mortality; major stroke; and life-threatening, disabling, or major bleeding. Mean echocardiographic follow-up was 471.35102.72 days. Results Mean age was 80.43 +/- 6.03 years and EuroSCORE II was 8.80 +/- 7.21%. Successful implantation was accomplished in 100% (n=28). Median transvalvular aortic mean pressure gradient was 44.5mm Hg (interquartile range [IQR]: 34.5; 55.5) preoperatively, 12mm Hg (IQR: 9; 16) postoperatively, and 11mm Hg (IQR: 8; 16) after 1 year. After 12 months, no paravalvular leakage was seen in 52.38% of the patients and grade 1 paravalvular leakage was seen in 47.62% of the patients. There was no grade 2 or 3 leakage detected. Stroke, valve thrombosis or dislocation, myocardial infarction, or bleeding was also not observed. However, criteria for the combined efficacy endpoint after 1year were met in five patients (17.86%). Thirty-day mortality was 14.29% (n=4) and all-cause mortality after 1year was 21.43% (n=6). Conclusion The JenaValve transapical TAVI system is a safe and feasible procedure with low peri- and postoperative complications and convincing midterm performance of the prosthesis.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 50 条
  • [41] First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up
    Ruiz, Carlos E.
    Laborde, Jean C.
    Condado, Jose F.
    Chiam, Paul T. L.
    Condado, Jose A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) : 143 - 148
  • [42] Transcatheter aortic valve implantation in very elderly patients: immediate results and medium term follow-up
    Pascual, Isaac
    Munoz-Garcia, Antonio J.
    Lopez-Otero, Diego
    Avanzas, Pablo
    Jimenez-Navarro, Manuel F.
    Cid-Alvarez, Belen
    del Valle, Raquel
    Alonso-Briales, Juan H.
    Ocaranza-Sanchez, Raimundo
    Hernandez, Jose M.
    Trillo-Nouche, Ramiro
    Moris, Cesar
    JOURNAL OF GERIATRIC CARDIOLOGY, 2015, 12 (04) : 340 - 345
  • [43] Pacemaker Implantation and Need for Ventricular Pacing during Follow-Up after Transcatheter Aortic Valve Implantation
    Ramazzina, Carola
    Knecht, Sven
    Jeger, Raban
    Kaiser, Christoph
    Schaer, Beat
    Osswald, Stefan
    Sticherling, Christian
    Kuehne, Michael
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (12): : 1592 - 1601
  • [44] Long-term Follow-up After Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis
    Salinas, Pablo
    Moreno, Raul
    Calvo, Luis
    Sanchez-Recalde, Angel
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Lopez-Fernandez, Teresa
    Ramirez, Ulises
    Riera, Luis
    Plaza, Ignacio
    Moreno, Isidro
    Maria Mesa, Jose
    Luis Lopez-Sendon, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (01): : 37 - 44
  • [45] Transcatheter aortic valve implantation in patients with high-risk aortic stenosis: a clinical follow-up
    Dagdelen, Sinan
    Karabulut, Hasan
    Senay, Sahin
    Akyol, Ahmet
    Toraman, Fevzi
    Cagli, Huseyin
    Aydin, Ebuzer
    Okten, Eyup
    Alhan, Cem
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 19 (04): : 495 - 502
  • [46] Complications after transcatheter aortic valve implantation using transfemoral and transapical approach in general anaesthesia
    Wurschinger, Fabian
    Wittmann, Sigrid
    Goldfuss, Sophia
    Zech, Nina
    Debl, Kurt
    Hilker, Michael
    Graf, Bernhard M.
    Zausig, York A.
    PLOS ONE, 2018, 13 (04):
  • [47] Aortic valve stenosis: transcatheter aortic valve implantation (TAVI) - transarterial or transapical approach
    Sack, S.
    Schelp, M. K.
    Poppe, S.
    Weber, M.
    Krueger, T.
    Geith, S.
    Lieber, M.
    Schleger, S.
    Eichinger, W.
    Menne, J.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2011, 136 (09) : 417 - 426
  • [48] One-year interim follow-up results of the TRAVERCE trial: the initial feasibility study for trans-apical aortic-valve implantation
    Walther, Thomas
    Kasimir, Marie-Theres
    Doss, Mirko
    Schuler, Gerhard
    Simon, Paul
    Schaechinger, Volker
    Mohr, Friedrich W.
    Wimmer-Greinecker, Gerhard
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (04) : 532 - 537
  • [49] Five-Year Follow-Up from the CoreValve Expanded Use Transcatheter Aortic Valve-in-Surgical Aortic Valve Study
    Bajwa, Tanvir K.
    Laham, Roger J.
    Khabbaz, Kamal
    Dauerman, Harold L.
    Waksman, Ron
    Weiss, Eric
    Allaqaband, Suhail
    Badr, Salem
    Caskey, Michael
    Byrne, Timothy
    Applegate, Robert J.
    Kon, Neal D.
    Li, Shuzhen
    Kleiman, Neal S.
    Reardon, Michael J.
    Chetcuti, Stanley J.
    Deeb, G. Michael
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 214 : 1 - 7
  • [50] Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Low-risk Patients: A Meta-Analysis Based on a 2-Year Follow-Up
    Chen, Chang-Gan
    Xi, Bei-Bei
    Deng, Qiu-Feng
    Zhang, Xin-Yuan
    Lin, Wei-Cheng
    Chen, Liang-Wan
    Qiu, Zhi-Huang
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (11) : 802 - +