Transapical Transcatheter Aortic Valve Implantation Using the JenaValve: A One-Year Follow-up

被引:7
|
作者
Reuthebuch, Oliver [1 ]
Koechlin, Luca [1 ]
Kaufmann, Beat A. [2 ]
Kessel-Schaefer, Arnheid [2 ]
Gahl, Brigitta [3 ]
Eckstein, Friedrich S. [1 ]
机构
[1] Univ Basel Hosp, Dept Cardiac Surg, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Cardiol, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Dept Cardiovasc Surg, CH-4031 Basel, Switzerland
来源
THORACIC AND CARDIOVASCULAR SURGEON | 2015年 / 63卷 / 06期
关键词
aortic valve and root; heart valve; transapical; TAVI; outcomes; SINGLE-CENTER EXPERIENCE; REGURGITATION; STENOSIS;
D O I
10.1055/s-0035-1552980
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Since the first transcatheter aortic valve implantation (TAVI) in 2002, TAVI technique has gained an increasing popularity especially in high-risk patients. In this study, we present the first echocardiographic midterm outcome with the second-generation transapical JenaValve TAVI system (JenaValve Technology GmbH, Munich, Germany) in patients with aortic stenosis (AS). Methods Between November 2011 and November 2012, a total of 28 patients received transapical TAVI using the JenaValve. Primary endpoint was a combined efficacy endpoint after 1year, which included all-cause mortality after more than 30 days, failure of current therapy for AS requiring hospitalization for symptoms of valve-related cardiac decompensation or prosthetic heart valve dysfunction. Moreover, we analyzed secondary endpoints after 3 and 12 months including cardiovascular mortality; major stroke; and life-threatening, disabling, or major bleeding. Mean echocardiographic follow-up was 471.35102.72 days. Results Mean age was 80.43 +/- 6.03 years and EuroSCORE II was 8.80 +/- 7.21%. Successful implantation was accomplished in 100% (n=28). Median transvalvular aortic mean pressure gradient was 44.5mm Hg (interquartile range [IQR]: 34.5; 55.5) preoperatively, 12mm Hg (IQR: 9; 16) postoperatively, and 11mm Hg (IQR: 8; 16) after 1 year. After 12 months, no paravalvular leakage was seen in 52.38% of the patients and grade 1 paravalvular leakage was seen in 47.62% of the patients. There was no grade 2 or 3 leakage detected. Stroke, valve thrombosis or dislocation, myocardial infarction, or bleeding was also not observed. However, criteria for the combined efficacy endpoint after 1year were met in five patients (17.86%). Thirty-day mortality was 14.29% (n=4) and all-cause mortality after 1year was 21.43% (n=6). Conclusion The JenaValve transapical TAVI system is a safe and feasible procedure with low peri- and postoperative complications and convincing midterm performance of the prosthesis.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 50 条
  • [1] Understanding experiences of undergoing transcatheter aortic valve implantation: one-year follow-up
    Baumbusch, Jennifer
    Lauck, Sandra B.
    Achtem, Leslie
    O'Shea, Tamar
    Wu, Sarah
    Banner, Davina
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2018, 17 (03) : 280 - 288
  • [2] Transapical transcatheter aortic valve implantation using the J-Valve system: A 1-year follow-up study
    Luo, Xiang
    Wang, Xu
    Li, Xuan
    Wang, Xin
    Xu, Fei
    Liu, Mingzheng
    Yu, Bing
    Li, Fei
    Tong, Minghui
    Wang, Wei
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (01): : 46 - 55
  • [3] One-year follow-up of conduction disturbances following transcatheter aortic valve implantation
    Salizzoni, Stefano
    Anselmino, Matteo
    Fornengo, Cristina
    Giordana, Francesca
    La Torre, Michele
    Moretti, Claudio
    D'Amico, Maurizio
    Omede, Pierluigi
    Marra, Sebastiano
    Rinaldi, Mauro
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2015, 16 (04) : 296 - 302
  • [4] Transapical transcatheter aortic valve implantation: Follow-up to 3 years
    Ye, Jian
    Cheung, Anson
    Lichtenstein, Samuel V.
    Nietlispach, Fabian
    Albugami, Saad
    Masson, Jean-Bernard
    Thompson, Christopher R.
    Munt, Brad
    Moss, Robert
    Carere, Ronald G.
    Jamieson, W. R. Eric
    Webb, John G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05): : 1107 - U27
  • [5] The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation
    Silaschi, Miriam
    Conradi, Lenard
    Wendler, Olaf
    Schlingloff, Friederike
    Kappert, Utz
    Rastan, Ardawan J.
    Baumbach, Hardy
    Holzhey, David
    Eichinger, Walter
    Bader, Ralf
    Treede, Hendrik
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (07) : 1345 - 1351
  • [6] Transcatheter aortic valve implantation using transfemoral/transsubclavian or transapical approach: 30-day follow-up of the initial 30 patients
    Witkowski, Adam
    Dabrowski, Maciej
    Chmielak, Zbigniew
    Demkow, Marcin
    Stepinska, Janina
    Juraszynski, Zbigniew
    Kusmierski, Krzysztof
    Michalek, Piotr
    Michalowska, Ilona
    Dziekiewicz, Miroslaw
    Sitkowska-Rysiak, Ewa
    Wolski, Piotr
    Ksiezycka, Ewa
    Czerwinska, Katarzyna
    Hryniewiecki, Tomasz
    Chojnowska, Stefania Lidia
    Ruzyllo, Witold
    KARDIOLOGIA POLSKA, 2011, 69 (02) : 105 - 115
  • [7] One-year multicentre outcomes of transapical aortic valve implantation using the SAPIEN XT™ valve: the PREVAIL transapical study
    Walther, Thomas
    Thielmann, Matthias
    Kempfert, Joerg
    Schroefel, Holger
    Wimmer-Greinecker, Gerhard
    Treede, Hendrik
    Wahlers, Thorsten
    Wendler, Olaf
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) : 986 - 992
  • [8] One-Year Outcomes of Transcatheter Aortic Valve Implantation Using the Direct Aortic Approach
    Bruschi, Giuseppe
    Branny, Marian
    Schiltgen, Molly
    Ettori, Federica
    Marcheix, Bertrand
    Amrane, Hafid
    Bushnaq, Hasan
    Tan, M. Erwin S. H.
    Trivedi, Uday
    Branny, Piotr
    Klugmann, Silvio
    Coletti, Giuseppe
    Dumonteil, Nicolas
    Porta, Fabiano
    Nordell, Anna
    Moat, Neil
    ANNALS OF THORACIC SURGERY, 2017, 103 (05): : 1434 - 1442
  • [9] Transapical transcatheter aortic valve implantation using a new second-generation TAVI system -J-Valve™ for high-risk patients with aortic valve diseases: Initial results with 90-day follow-up
    Zhu, Da
    Chen, Yucheng
    Guo, Yingqiang
    Hu, Jia
    Zhang, Ji
    Wei, Xin
    Tang, Hong
    Shi, Yingkang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 : 155 - 162
  • [10] One-Year Results of Transcatheter Aortic Valve Implantation in Severe Symptomatic Aortic Valve Stenosis
    Gotzmann, Michael
    Bojara, Waldemar
    Lindstaedt, Michael
    Ewers, Aydan
    Boesche, Leif
    Germing, Alfried
    Lawo, Thomas
    Bechtel, Matthias
    Laczkovics, Axel
    Muegge, Andreas
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (11): : 1687 - 1692