Experimental Research on Concrete Beams Reinforced with High Ductility Steel Bars and Strengthened with a Reactive Powder Concrete Layer in the Compression Zone

被引:9
作者
Perkowski, Zbigniew [1 ]
Czabak, Mariusz [1 ]
Grzeszczyk, Stefania [2 ]
Fraczek, Daniel [1 ]
Tatara, Karolina [1 ]
Matuszek-Chmurowska, Aneta [2 ]
Jurowski, Krystian [2 ]
Jedraszak, Bronislaw [3 ]
机构
[1] Opole Univ Technol, Dept Phys Mat, Fac Civil Engn & Architecture, Katowicka 48, PL-45061 Opole, Poland
[2] Opole Univ Technol, Dept Bldg Mat Engn, Fac Civil Engn & Architecture, Katowicka 48, PL-45061 Opole, Poland
[3] Opole Univ Technol, Dept Mech & Struct Engn, Struct Engn Lab, Fac Civil Engn & Architecture, Katowicka 48, PL-45061 Opole, Poland
关键词
ultra-high performance fibre reinforced concrete; reactive powder concrete; composite beam; destructive tests; displacement measurement; strain measurement; curvature measurement; ultrasonic tests; photogrammetric analysis; cracks; reinforcing steel of high ductility; FLEXURAL BEHAVIOR; PREDICTION; COLUMNS; BRIDGE; FRP;
D O I
10.3390/ma13184173
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The article describes four-point bending tests of three reinforced concrete beams with identical cross-sections, spans, and high-ductility steel reinforcement systems. Two beams were strengthened in the compressed section with a thin layer of reactive powder concrete (RPC) bonded with evenly spaced stirrups. Their remaining sections, and the third reference beam, were made of ordinary concrete. Measurements of their deflections, strains and axis curvature; ultrasonic tests; and a photogrammetric analysis of the beams are the main results of the study. For one of the beams with the RPC, the load was increased in one stage. For the two remaining beams, the load was applied in four stages, increasing the maximum load from stage to stage in order to allow the analysis of the damage evolution before reaching the bending resistance. The most important effect observed was the stable behaviour of the strengthened beams in the post-critical state, as opposed to the reference beam, which had about two to three times less energy-absorbing capacity in this range. Moreover, thanks to the use of the RPC layer, the process of concrete cover delamination in the compression zone was significantly reduced, the high ductility of the rebars was fully utilized during the formation of plastic hinges, and the bending capacity was increased by approximately 12%.
引用
收藏
页数:39
相关论文
共 60 条
  • [1] Flexural behavior of reinforced concrete beams strengthened with ultra-high performance fiber reinforced concrete
    Al-Osta, M. A.
    Isa, M. N.
    Baluch, M. H.
    Rahman, M. K.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 134 : 279 - 296
  • [2] [Anonymous], 1999, BS EN 1015-3, Patent No. 0310414
  • [3] [Anonymous], 2016, 123909 CENTS
  • [4] [Anonymous], 2011, EN197-1, DOI DOI 10.31030/1758792
  • [5] [Anonymous], 2013, ULTR PERF CONCR UHPC
  • [6] ASTM, 2000, ASTM D 2845 - 00
  • [7] Long-term Behavior of Ultra - High Performance Concrete (UHPC) Bended Beams
    Barbos, Gheorghe-Alexandru
    [J]. 9TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2015, 2016, 22 : 203 - 210
  • [8] Precast, prestressed pedestrian bridge - World's first reactive powder concrete structure
    Blais, PY
    Couture, M
    [J]. PCI JOURNAL, 1999, 44 (05): : 60 - 71
  • [9] CEN, 2019, EN 12390-3)
  • [10] CEN, 2013, EN 12390-13