Speckle tracking for multi-dimensional flow estimation

被引:202
作者
Bohs, LN
Geiman, BJ
Anderson, ME
Gebhart, SC
Trahey, GE
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
关键词
angle-independent flow; flow quantification; flow velocity; vector velocity;
D O I
10.1016/S0041-624X(99)00182-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Speckle tracking methods overcome the major limitations of current Doppler methods for how imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a single transducer aperture. Ensemble tracking, a recent speckle tracking method based upon parallel receive processing, is described. Experimental results with ensemble tracking indicate the ability to measure laminar flow in a phantom at a beam-vessel angle of 60 degrees, which had not been possible with previous 2D speckle tracking methods. Finally, important areas for future research in speckle tracking are briefly summarized. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 22 条
[11]   A THEORETICAL AND EXPERIMENTAL-ANALYSIS OF THE RECEIVED SIGNAL FROM DISTURBED BLOOD-FLOW [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) :172-184
[12]   Speckle decorrelation due to two-dimensional flow gradients [J].
Friemel, BH ;
Bohs, LN ;
Nightingale, KR ;
Trahey, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :317-327
[13]  
GEIMAN BJ, 2000, IN PRESS PHYSICS MED
[15]   CURRENT TIME-DOMAIN METHODS FOR ASSESSING TISSUE MOTION BY ANALYSIS FROM REFLECTED ULTRASOUND ECHOES - A REVIEW [J].
HEIN, IA ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (02) :84-102
[16]   3-D flow velocity vector estimation with a triple-beam lens transducer - Experimental results [J].
Hein, IA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :85-95
[17]   POTENTIAL AND LIMITATIONS OF ANGLE-INDEPENDENT FLOW DETECTION ALGORITHMS USING RADIOFREQUENCY AND DETECTED ECHO SIGNALS [J].
RAMAMURTHY, BS ;
TRAHEY, GE .
ULTRASONIC IMAGING, 1991, 13 (03) :252-268
[18]   MEASUREMENT OF VELOCITY OF PROPAGATION FROM ULTRASONIC PULSE-ECHO DATA [J].
ROBINSON, DE ;
CHEN, F ;
WILSON, LS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (04) :413-&
[19]   EXPLOSOSCAN - A PARALLEL PROCESSING TECHNIQUE FOR HIGH-SPEED ULTRASOUND IMAGING WITH LINEAR PHASED-ARRAYS [J].
SHATTUCK, DP ;
WEINSHENKER, MD ;
SMITH, SW ;
VONRAMM, OT .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 75 (04) :1273-1282
[20]   HIGH-SPEED ULTRASOUND VOLUMETRIC IMAGING-SYSTEM .1. TRANSDUCER DESIGN AND BEAM STEERING [J].
SMITH, SW ;
PAVY, HG ;
VONRAMM, OT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (02) :100-108