Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device

被引:12
作者
Date, Kazuma [1 ,2 ]
Nishimura, Takashi [3 ]
Arakawa, Mamoru [1 ]
Takewa, Yoshiaki [1 ]
Kishimoto, Satoru [1 ]
Umeki, Akihide [2 ]
Ando, Masahiko [2 ]
Mizuno, Toshihide [1 ]
Tsukiya, Tomonori [1 ]
Ono, Minoru [2 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Artificial Organs, 5-7-1 Fujishiro Dai, Suita, Osaka 5658565, Japan
[2] Univ Tokyo, Dept Cardiothorac Surg, Tokyo, Japan
[3] Tokyo Metropolitan Geriatr Hosp, Dept Cardiac Surg, Itabashi Ku, 35-2 Sakaecho, Tokyo 1730015, Japan
关键词
Continuous-flow LVAD; Synchronization with cardiac beat; Rotary pump; LEFT-HEART BYPASS; BEAT SYNCHRONIZING SYSTEM; FLOW; SUPPORT; PERFUSION; PRESSURE; RECOVERY; MODEL;
D O I
10.1007/s10047-016-0920-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART(A (R)); Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 +/- 4.3 kg) with normal hearts. We reduced their heart rates to < 60 bpm using propranolol and controlled the heart rates at 80 and 120 bpm using ventricular pacing. We shifted the timing of increasing RS from -60 to +60 ms in the systolic phase. We found significant increases in all the following parameters when assessments of delayed timing (+60 ms) were compared with assessments of advanced timing (-60 ms): pulse pressure, mean dP/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 50 条
[41]   Computational Fluid Dynamics Study of Cerebral Thromboembolism Risk in Ventricular Assist Device Patients: Effects of Pulsatility and Thrombus Origin [J].
Prather, Ray ;
Divo, Eduardo ;
Kassab, Alain ;
DeCampli, William .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (09)
[42]   Minimally Invasive Right Ventricular Assist Device Implantation in a Patient with HeartWare left ventricular Assist Device [J].
Maxhera, Bujar ;
Albert, Alexander ;
Westenfeld, Ralf ;
Boeken, Udo ;
Lichtenberg, Artur ;
Saeed, Diyar .
ASAIO JOURNAL, 2015, 61 (06) :E42-E43
[43]   Design and In Vitro Testing of Pulsatile Varying Speed Controller for Continuous-Flow Left Ventricular Assist Device [J].
Liu, Hongtao ;
Wang, Wencheng ;
Zhao, Sipeng ;
Xing, Fayu ;
Zhang, Yunpeng ;
Wu, Xiaojin ;
He, Tao .
IEEE SENSORS JOURNAL, 2024, 24 (13) :21500-21510
[44]   In-silico evaluation of left ventricular unloading under varying speed continuous flow left ventricular assist device support [J].
Bozkurt, Selim ;
Bozkurt, Surhan .
BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2017, 37 (03) :373-387
[45]   Correlation between Myocardial Function and Electric Current Pulsatility of the Sputnik Left Ventricular Assist Device: In-Vitro Study [J].
Telyshev, Dmitry V. ;
Pugovkin, Alexander A. ;
Ephimov, Ivan A. ;
Markov, Aleksandr ;
Leonhardt, Steffen ;
Walter, Marian ;
Karimov, Jamshid H. ;
Selishchev, Sergey V. .
APPLIED SCIENCES-BASEL, 2021, 11 (08)
[46]   Derived and Displayed Power Consumption, Flow, and Pulsatility Over a Range of HeartMate II Left Ventricular Assist Device Settings [J].
Lund, Lars H. ;
Gabrielsen, Anders ;
Tiren, Linnea ;
Hallberg, Ann ;
El Karlsson, Kerstin ;
Eriksson, Maria J. .
ASAIO JOURNAL, 2012, 58 (03) :183-190
[47]   Ventricular Arrhythmias in Patients With Left Ventricular Assist Device (LVAD) [J].
Ahmed, Azza ;
Amin, Mustapha ;
Boilson, Barry A. ;
Killu, Ammar M. ;
Madhavan, Malini .
CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2019, 21 (11)
[48]   Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system [J].
Kazuma Date ;
Takashi Nishimura ;
Yoshiaki Takewa ;
Satoru Kishimoto ;
Mamoru Arakawa ;
Akihide Umeki ;
Masahiko Ando ;
Toshihide Mizuno ;
Tomonori Tsukiya ;
Minoru Ono ;
Eisuke Tatsumi .
Journal of Artificial Organs, 2016, 19 :315-321
[49]   Ventricular Energetics in Pediatric Left Ventricular Assist Device Patients: A Retrospective Clinical Study [J].
Di Molfetta, Arianna ;
Ferrari, Gianfranco ;
Iacobelli, Roberta ;
Filippelli, Sergio ;
Di Chiara, Luca ;
Guccione, Paolo ;
Amodeo, Antonio .
ASAIO JOURNAL, 2017, 63 (06) :815-823
[50]   Feasibility of cell transplantation with a left ventricular assist device to improve the success rate of left ventricular assist device removal: the first experiment [J].
Mizuno, Tomohiro .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (01) :10-14