Correlations of Salivary and Blood Glucose Levels among Six Saliva Collection Methods

被引:35
作者
Cui, Yangyang [1 ,2 ,3 ]
Zhang, Hankun [1 ,3 ]
Zhu, Jia [1 ,2 ,3 ]
Liao, Zhenhua [3 ]
Wang, Song [3 ]
Liu, Weiqiang [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Mech Engn, Beijing 100084, Peoples R China
[3] Tsinghua Univ Shenzhen, Biomech & Biotechnol Lab, Res Inst, Shenzhen 518057, Peoples R China
关键词
saliva collection method; salivary glucose; blood glucose; diabetes mellitus; correlation;
D O I
10.3390/ijerph19074122
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Saliva has been studied as a better indicator of disorders and diseases than blood. Specifically, the salivary glucose level is considered to be an indicator of diabetes mellitus (DM). However, saliva collection methods can affect the salivary glucose level, thereby affecting the correlation between salivary glucose and blood glucose. Therefore, this study aims to identify an ideal saliva collection method and to use this method to determine the population and individual correlations between salivary glucose and blood glucose levels in DM patients and healthy controls. Finally, an analysis of the stability of the individual correlations is conducted. Methods: This study included 40 age-matched DM patients and 40 healthy controls. In the fasting state, saliva was collected using six saliva collection methods, venous blood was collected simultaneously from each study participant, and both samples were analyzed at the same time using glucose oxidase peroxidase. A total of 20 DM patients and 20 healthy controls were arbitrarily selected from the above participants for one week of daily testing. The correlations between salivary glucose and blood glucose before and after breakfast were analyzed. Finally, 10 DM patients and 10 healthy controls were arbitrarily selected for one month of daily testing to analyze the stability of individual correlations. Results: Salivary glucose levels were higher in DM patients than healthy controls for the six saliva collection methods. Compared with unstimulated saliva, stimulated saliva had decreased glucose level and increased salivary flow. In addition, unstimulated parotid salivary glucose was most correlated with blood glucose level (R-2 = 0.9153), and the ROC curve area was 0.9316, which could accurately distinguish DM patients. Finally, it was found that the correlations between salivary glucose and blood glucose in different DM patients were quite different. The average correlation before breakfast was 0.83, and the average correlation after breakfast was 0.77. The coefficient of variation of the correlation coefficient before breakfast within 1 month was less than 5%. Conclusion: Unstimulated parotid salivary glucose level is the highest and is most correlated with blood glucose level, which can be accurately used to distinguish DM patients. Meanwhile, the correlation between salivary glucose and blood glucose was found to be relatively high and stable before breakfast. In general, the unstimulated parotid salivary glucose before breakfast presents an ideal saliva collecting method with which to replace blood-glucose use to detect DM, which provides a reference for the prediction of DM.
引用
收藏
页数:15
相关论文
共 54 条
  • [1] Glucose estimation in the salivary secretion of diabetes mellitus patients
    Abikshyeet, Panda
    Ramesh, Venkatapathy
    Oza, Nirima
    [J]. DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2012, 5 : 149 - 154
  • [2] Tackling type 2 diabetes-associated cardiovascular and renal comorbidities: a key challenge for drug development
    Adeghate, Ernest A.
    Kalasz, Huba
    Al Jaberi, Saeeda
    Adeghate, Jennifer
    Tekes, Kornelia
    [J]. EXPERT OPINION ON INVESTIGATIONAL DRUGS, 2021, 30 (02) : 85 - 93
  • [3] Oral Health Messiers: Diabetes Mellitus Relevance
    Ahmad, Rahnuma
    Haque, Mainul
    [J]. DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2021, 14 : 3001 - 3015
  • [4] A wearable patch for continuous monitoring of sweat electrolytes during exertion
    Alizadeh, Azar
    Burns, Andrew
    Lenigk, Ralf
    Gettings, Rachel
    Ashe, Jeffrey
    Porter, Adam
    McCaul, Margaret
    Barrett, Ruairi
    Diamond, Dermot
    White, Paddy
    Skeath, Perry
    Tomczak, Melanie
    [J]. LAB ON A CHIP, 2018, 18 (17) : 2632 - 2641
  • [5] Amer S, 2001, Pak J Pharm Sci, V14, P33
  • [6] Continuous Non-Invasive Glucose Monitoring via Contact Lenses: Current Approaches and Future Perspectives
    Bamgboje, David
    Christoulakis, Iasonas
    Smanis, Ioannis
    Chavan, Gaurav
    Shah, Rinkal
    Malekzadeh, Masoud
    Violaris, Ioannis
    Giannakeas, Nikolaos
    Tsipouras, Markos
    Kalafatakis, Konstantinos
    Tzallas, Alexandros
    [J]. BIOSENSORS-BASEL, 2021, 11 (06):
  • [7] Effect of propolis mouth rinse on oral microorganisms - a randomized controlled trial
    Bapat, Salil
    Nagarajappa, Ramesh
    Ramesh, Gayathri
    Bapat, Kruti
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (11) : 6139 - 6146
  • [8] Belazi M A, 1998, Int J Paediatr Dent, V8, P29, DOI 10.1046/j.1365-263X.1998.00057.x
  • [9] Validation and verification of predictive salivary biomarkers for oral health
    Bostanci, Nagihan
    Mitsakakis, Konstantinos
    Afacan, Beral
    Bao, Kai
    Johannsen, Benita
    Baumgartner, Desiree
    Mueller, Lara
    Kotolova, Hana
    Emingil, Guelnur
    Karpisek, Michal
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [10] Salivary molecular spectroscopy: A sustainable, rapid and non-invasive monitoring tool for diabetes mellitus during insulin treatment
    Caixeta, Douglas C.
    Aguiar, Emilia M. G.
    Cardoso-Sousa, Leia
    Coelho, Liris M. D.
    Oliveira, Stephanie W.
    Espindola, Foued S.
    Raniero, Leandro
    Crosara, Karla T. B.
    Baker, Matthew J.
    Siqueira, Walter L.
    Sabino-Silva, Robinson