Evaluation of a micro-fabricated pyrolyzer for the detection of Bacillus anthracis spores

被引:11
作者
Havey, CD
Basile, F
Mowry, C
Voorhees, KJ [1 ]
机构
[1] Colorado Sch Mines, Dept Chem & Geochem, Golden, CO 80401 USA
[2] Sandia Natl Labs, Micro Analyt Syst Dept, Albuquerque, NM 87185 USA
关键词
Bacillus anthracis; pyrolyzer; spores; micro;
D O I
10.1016/j.jaap.2004.02.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro-fabricated device for pyrolysis (i.e. micro-pyrolyzer) has been evaluated for pyrolysis and thermal hydrolysis methylation using Bacillus anthracis spores. The micro-pyrolyzer consists of a silicon wafer substrate with either a circular (2.7 mm diameter) or square (6.25 mm(2) area) silicon-nitride membrane heated by a platinum resistive element. A metal housing (i.e. test fixture) encloses the micro-pyrolyzer and serves as a manifold for the air carrier gas. The test fixture was interfaced to a quadrupole ion trap mass spectrometer via a direct capillary (100 mum x 1.4 m). The 360-440degreesC pyrolysis of B. anthracis spores produced dipicolinic acid (DPA) similar to that from a furnace pyrolyzer. In further studies, B. anthracis spores subjected to thermal hydrolysis methylation conditions produced ions characteristic of dipicolinic acid dimethyl ester. Results demonstrate the micro-pyrolyzer devices are capable of temperatures and heating rates to perform pyrolysis and thermal hydrolysis methylation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 27 条
  • [1] AbbasHawks C, 1996, RAPID COMMUN MASS SP, V10, P1802, DOI 10.1002/(SICI)1097-0231(199611)10:14<1802::AID-RCM761>3.0.CO
  • [2] 2-Y
  • [3] Beverly MB, 1996, RAPID COMMUN MASS SP, V10, P455, DOI 10.1002/(SICI)1097-0231(19960315)10:4<455::AID-RCM500>3.3.CO
  • [4] 2-P
  • [5] Review: the development and applications of thermally assisted hydrolysis and methylation reactions
    Challinor, JM
    [J]. JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2001, 61 (1-2) : 3 - 34
  • [6] High-speed gas chromatography: an overview of various concepts
    Cramers, CA
    Janssen, HG
    van Deursen, MM
    Leclercq, PA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 315 - 329
  • [7] DONG P, 1997, J U PETROLEUM CHINA, V21, P102
  • [8] Dworzanski JP, 1997, FIELD ANAL CHEM TECH, V1, P295, DOI 10.1002/(SICI)1520-6521(1997)1:5<295::AID-FACT5>3.0.CO
  • [9] 2-T
  • [10] Detection of the dipicolinic acid biomarker in Bacillus spores using Curie-point pyrolysis mass spectrometry and fourier transform infrared spectroscopy
    Goodacre, R
    Shann, B
    Gilbert, RJ
    Timmins, ÉM
    McGovern, AC
    Alsberg, BK
    Kell, DB
    Logan, NA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 119 - 127