Evaluation of in-tube solid-phase microextraction method for co-extraction of acidic, basic, and neutral drugs

被引:17
作者
Asiabi, Hamid [1 ]
Yamini, Yadollah [1 ]
Seidi, Shahram [2 ]
Safari, Meysam [1 ]
Shamsayei, Maryam [1 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, POB 14115-175, Tehran, Iran
[2] KN Toosi Univ Technol, Dept Analyt Chem, Fac Chem, Tehran, Iran
关键词
MICRO-EXTRACTION; MASS-SPECTROMETRY; COATED CAPILLARY; POLYPYRROLE; POLYMER; WATER; PRECONCENTRATION; CHROMATOGRAPHY; ENVIRONMENT; COPOLYMERS;
D O I
10.1039/c5ra27825b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Simultaneous extraction of acidic, basic, and neutral drugs from different biological samples is a considerable and disputable concept in sample preparation strategies. In the present work, a new in-tube solid phase microextraction approach named electrochemically controlled double in-tube solid phase microextraction (EC-DIT-SPME) is introduced for simultaneous extraction of acidic, basic, and neutral drugs from different biological matrices. For this purpose, novel nanostructured coatings based on copolymer of polypyrrole and indole-2-carboxylic acid (PPy-co-PIca) as non-overoxidized and overoxidized forms were electrochemically synthesized on the inner surface of stain-less steel tubes. During the extraction procedure, the PPy-co-PIca and overoxidized PPy-co-PIca coated stain-less steel tubes were used as anode and cathode electrodes, respectively. Extraction of basic and acidic drugs were performed on the surface of overoxidized PPy-co-PIca and PPy-co-PIca, which are connected to the negative and positive potentials, respectively. With regard to the fact that neutral drugs can be absorbed in both electrodes, extraction of neutral drugs will be done in both of them. Satisfactory analytical figures of merit including linear dynamic range and limits of detection in the range of 0.15-500 ng mL(-1) and 0.05-1.9 ng mL(-1) and good extraction recoveries (38.5-78.6%) were obtained. Finally, the proposed method was successfully applied for simultaneous analysis of acidic, basic, and neutral drugs in some biological samples.
引用
收藏
页码:14049 / 14058
页数:10
相关论文
共 33 条
[11]   Ordered mesoporous silica coated capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography [J].
Fan, Y ;
Feng, YQ ;
Shi, ZG ;
Wang, JB .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :1-8
[12]   Poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography and its application to determination of basic drugs in human serum [J].
Fan, Y ;
Feng, YQ ;
Da, SL ;
Shi, ZG .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :251-258
[13]   Dopamine voltammetry at overoxidised polyindole electrodes [J].
Ghita, M ;
Arrigan, DWM .
ELECTROCHIMICA ACTA, 2004, 49 (26) :4743-4751
[14]   Molecularly imprinted polymers and their use in biomimetic sensors [J].
Haupt, K ;
Mosbach, K .
CHEMICAL REVIEWS, 2000, 100 (07) :2495-2504
[15]   Occurrence, fate, and removal of pharmaceutical residues in the aquatic environment: a review of recent research data [J].
Heberer, T .
TOXICOLOGY LETTERS, 2002, 131 (1-2) :5-17
[16]   Electrochemically controlled solid-phase micro-extraction of proline using a nanostructured film of polypyrrole, and its determination by ion mobility spectrometry [J].
Kalhor, Hamideh ;
Ameli, Akram ;
Alizadeh, Naader .
MICROCHIMICA ACTA, 2013, 180 (9-10) :783-789
[17]   Preparation and SEESR-spectroscopic investigations of indole/pyrrole copolymers in aprotic medium [J].
Köleli, F ;
Arslan, Y ;
Düdükcü, M .
SYNTHETIC METALS, 2002, 129 (01) :47-52
[18]   A novel voltammetric sensor for ascorbic acid based on molecularly imprinted poly(o-phenylenediamine-co-o-aminophenol) [J].
Kong, Yong ;
Shan, Xueling ;
Ma, Jianfeng ;
Chen, Meilan ;
Chen, Zhidong .
ANALYTICA CHIMICA ACTA, 2014, 809 :54-60
[19]   A review on development of solid phase microextraction fibers by sol-gel methods and their applications [J].
Kumar, Ashwini ;
Gaurav ;
Malik, Ashok Kumar ;
Tewary, Dhananjay Kumar ;
Singh, Baldev .
ANALYTICA CHIMICA ACTA, 2008, 610 (01) :1-14
[20]   Electrochemically controlled solid-phase microextraction and preconcentration using polypyrrole coated microarray electrodes in a flow system [J].
Liljegren, G ;
Nyholm, L .
ANALYST, 2003, 128 (03) :232-236