Interactions of intercalating fluorochromes with DNA analyzed by conventional and fluorescence lifetime flow cytometry utilizing deuterium oxide

被引:0
作者
Sailer, BL [1 ]
Nastasi, AJ [1 ]
Valdez, JG [1 ]
Steinkamp, JA [1 ]
Crissman, HA [1 ]
机构
[1] LOS ALAMOS NATL LAB,DIV LIFE SCI,LOS ALAMOS,NM 87545
来源
CYTOMETRY | 1996年 / 25卷 / 02期
关键词
fluorescence lifetime; propidium iodide; ethidium bromide; chromatin structure; flow cytometry; apoptosis;
D O I
10.1002/(SICI)1097-0320(19961001)25:2<164::AID-CYTO5>3.0.CO;2-H
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Deuterium oxide (D2O) has been shown in previous studies to increase both the fluorescence Lifetime and fluorescence intensity of propidium iodide (PI) and ethidium bromide (EB) when bound to nucleic acid structures, We have used spectroscopic analysis and conventional and phase-sensitive now cytometry to compare changes in PI and EB fluorescence intensity and lifetime bound to DNA and fixed Chinese hamster ovary (CHO) cells in the presence of D2O vs. phosphate-buffered saline (PBS), Spectroscopic and now cytometric studies showed a twofold enhancement of fluorescence intensity of PI and EB bound to fixed CHO cells in D2O and a 5 ns increase in PI and EB fluorescence lifetimes in D2O. The fluorescence lifetime of HL-60 cells stained with PI of EB was found to be 1-2 ns different from that of CHO cells, indicating that the lifetime of these fluorochromes is sensitive to chromatin configuration in different cells types. Apoptotic subpopulations of HL-60 cells had a significantly reduced fluorescence lifetime compared to nonapoptotic subpopulations. Results indicate that different chromatin states, or differences in the structures of PI and EB, lead to alterations in the fluorescence intensity and fluorescence Lifetime of these intercalating probes. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:164 / 172
页数:9
相关论文
共 26 条
  • [1] [Anonymous], 1983, EXCITED STATE LIFETI
  • [2] BIRNBOIM HC, 1981, CANCER RES, V41, P1889
  • [3] RAPID, SIMULTANEOUS MEASUREMENT OF DNA, PROTEIN, AND CELL VOLUME IN SINGLE CELLS FROM LARGE MAMMALIAN-CELL POPULATIONS
    CRISSMAN, HA
    STEINKAMP, JA
    [J]. JOURNAL OF CELL BIOLOGY, 1973, 59 (03) : 766 - 771
  • [4] FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY
    DARZYNKIEWICZ, Z
    BRUNO, S
    DELBINO, G
    GORCZYCA, W
    HOTZ, MA
    LASSOTA, P
    TRAGANOS, F
    [J]. CYTOMETRY, 1992, 13 (08): : 795 - 808
  • [5] FLUORESCENCE LIFETIME MEASUREMENTS IN A FLOW CYTOMETER BY AMPLITUDE DEMODULATION USING DIGITAL DATA-ACQUISITION TECHNIQUE
    DEKA, C
    SKLAR, LA
    STEINKAMP, JA
    [J]. CYTOMETRY, 1994, 17 (01): : 94 - 101
  • [6] Dewey T.G., 1991, BIOPHYSICAL BIOCH AS
  • [7] IMPULSE FLUOROMETRY IN SINGLE CELLS IN SUSPENSIONS
    DITTRICH, W
    GOHDE, W
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG PART B-CHEMIE BIOCHEMIE BIOPHYSIK BIOLOGIE UND VERWANDTEN GEBIETE, 1969, B 24 (03): : 360 - &
  • [8] Dorr F., 1983, BIOPHYSICS, P265
  • [9] A SELECTIVE PROCEDURE FOR DNA EXTRACTION FROM APOPTOTIC CELLS APPLICABLE FOR GEL-ELECTROPHORESIS AND FLOW-CYTOMETRY
    GONG, JP
    TRAGANOS, F
    DARZYNKIEWICZ, Z
    [J]. ANALYTICAL BIOCHEMISTRY, 1994, 218 (02) : 314 - 319
  • [10] A CONTINUOUSLY VARIABLE FREQUENCY CROSS-CORRELATION PHASE FLUOROMETER WITH PICOSECOND RESOLUTION
    GRATTON, E
    LIMKEMAN, M
    [J]. BIOPHYSICAL JOURNAL, 1983, 44 (03) : 315 - 324