Effect of a virtual reality-enhanced exercise protocol after coronary artery bypass grafting

被引:24
作者
Chuang, Tien-Yow
Sung, Wen-Hsu
Chang, Hwa-Ann
Wang, Ray-Yau
机构
[1] Vet Gen Hosp, Dept Phys Med & Rehabil, Taipei 11217, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[3] I Shou Univ, Dept Biomed Engn, Kaohsiung, Taiwan
[4] Natl Yang Ming Univ, Inst Phys Therapy, Taipei, Taiwan
[5] Natl Yang Ming Univ, Fac Phys Therapy, Taipei, Taiwan
来源
PHYSICAL THERAPY | 2006年 / 86卷 / 10期
关键词
cardiopulmonary test; endurance exercise; rehabilitation; revascularization; simulation;
D O I
10.2522/ptj.20050335
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. Virtual reality (VR) technology has gained importance in many areas of medicine. Knowledge concerning the application and the influence of VR-enhanced exercise programs is limited for patients receiving coronary artery bypass grafting. The purpose of this study was to evaluate the effect of a virtual "country walk" on the number of sessions necessary to reach cardiac rehabilitation goals in patients undergoing coronary artery bypass grafting. Subjects. Twenty subjects who were seen for cardiac rehabilitation between January and June 2004 comprised the study sample. Methods. The protocol for this study included an initial maximum graded exercise tolerance test, given to determine the subsequent training goals for the subject, followed by biweekly submaximal endurance training sessions. All subjects were assigned by lot to 1 of 2 submaximal endurance training programs, one (group 2) with and the other (group 1) without the added VR environment. In all other respects, the 2 programs were identical. Each training session lasted for 30 minutes and was carried out twice per week for about 3 months. The primary outcome measures were maximum load during the work sessions, target oxygen consumption, target heart rate (beats per minute), and number of training sessions required to reach rehabilitation goals. Results. By the end of 20 training sessions, only 4 of the 10 control subjects had reached the heart rate target goal of 85% their maximum heart rate. In contrast, 9 of the 10 subjects in the VR program had attained this goal by 9 or fewer training sessions. When target metabolic cost (75% peak oxygen consumption) was used as the training goal, all 10 subjects in the VR program had reached this target after 2 training sessions (or, in some cases, 1 training session), but not until training session 15 did a cumulative number of 9 control subjects reach this goal. Discussion and Conclusion. These study outcomes clearly support the notion that incorporating a VR environment into cardiac rehabilitation programs will accelerate maximum recovery of patients' cardiovascular function.
引用
收藏
页码:1369 / 1377
页数:9
相关论文
共 19 条
  • [1] *AM COLL SPORTS ME, 2000, ACSMS GUID EX TEST P, P137
  • [2] American College of Sports Medicine, 1995, ACSMS GUID EX TEST P, P153
  • [3] Effects of virtual reality-enhanced exercise equipment on adherence and exercise-induced feeling states
    Annesi, JJ
    Mazas, J
    [J]. PERCEPTUAL AND MOTOR SKILLS, 1997, 85 (03) : 835 - 844
  • [4] [Anonymous], ACSMS GUID EX TEST P
  • [5] ARSTILLA M, 1972, ACTA MED SCAND, V529, P103
  • [6] BURDEA G, 1994, VIRTUAL REALITY TECH, P273
  • [7] Application of a virtual reality-enhanced exercise protocol in patients after coronary bypass
    Chuang, TY
    Sung, WH
    Lin, CY
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (10): : 1929 - 1932
  • [8] Virtual reality serves as a support technology in cardiopulmonary exercise testing
    Chuang, TY
    Chen, CH
    Chang, HA
    Lee, HC
    Chou, CL
    Doong, JL
    [J]. PRESENCE-TELEOPERATORS AND VIRTUAL ENVIRONMENTS, 2003, 12 (03) : 326 - 331
  • [9] HARTUNG GH, 1981, ARCH PHYS MED REHAB, V62, P147
  • [10] Upper and lower extremity robotic devices for rehabilitation and for studying motor control
    Hesse, S
    Schmidt, H
    Werner, C
    Bardeleben, A
    [J]. CURRENT OPINION IN NEUROLOGY, 2003, 16 (06) : 705 - 710