Comparison of a Distal Tibial Allograft and Scapular Spinal Autograft for Posterior Shoulder Instability With Glenoid Bone Loss

被引:19
作者
Nacca, Christopher [1 ]
Gil, Joseph A. [1 ]
DeFroda, Steven F. [1 ]
Badida, Rohit [1 ]
Owens, Brett D. [1 ]
机构
[1] Brown Univ, Warren Alpert Med Sch, 222 Richmond St, Providence, RI 02903 USA
基金
美国国家卫生研究院;
关键词
instability; shoulder; bone graft; glenoid defect; posterior shoulder dislocation; GLENOHUMERAL INSTABILITY; RECONSTRUCTION; AUGMENTATION; DIAGNOSIS;
D O I
10.1177/2325967118786697
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Posterior glenoid bone deficiency can occur with recurrent glenohumeral instability. Glenoid reconstruction with a distal tibial allograft (DTA) has been reported to successfully restore contact pressures that occur during posterior glenohumeral translation. However, there are concerns regarding the risk of allograft resorption, availability, and costs. Extracapsular reconstruction using a scapular spinal autograft (SSA) has been reported as an alternative technique secondary to its anatomic location relative to the posterior shoulder and preferable autograft properties. There are no known prior biomechanical studies evaluating the scapular spine as an effective extracapsular graft choice. Purpose: To compare the efficacy of a DTA and SSA in restoring the stability of a glenoid with a large posterior bone defect compared with the intact native glenoid. Study Design: Controlled laboratory study. Methods: Ten cadaveric shoulders were tested. With the use of a custom KUKA robot, a 50-N compressive force was applied to the glenohumeral joint. The peak force required to translate the humeral head beyond the glenoid lip posteriorly as well as the lateral displacement that occurred during posterior translation were measured. Testing was performed in 5 conditions: (1) intact glenoid and labrum, (2) simulated reverse Bankart lesion, (3) 12-mm posterior glenoid defect, (4) glenoid defect reconstructed with a fresh DTA, and (5) glenoid defect reconstructed with an SSA. Results: The mean glenoid width was 30 mm. The mean peak force and lateral displacement decreased significantly with a glenoid defect (0.99 2.3 N and 0.06 0.09 mm, respectively; P < .0001) compared with the intact glenoid (23.00 +/- 9.7 N and 1.83 +/- 0.70 mm, respectively; P = .0001). There was no significant difference between the peak force after reconstruction of the defect with a DTA (23.00 +/- 7.4 N) and SSA (23.00 +/- 7.7 N) when compared with the intact glenoid (P = .9999). There were no significant differences in the peak force between the 2 grafts (P = .9999). Additionally, both the DTA (1.04 +/- 1.09 mm) and the SSA (1.02 +/- 1.17 mm) demonstrated no differences in lateral displacement when compared with the intact glenoid (P = .2336 and .2043, respectively). There was no difference in lateral displacement that occurred between the DTA and SSA (P = .9999). Conclusion: Reconstruction of a large posterior glenoid defect with either a DTA or an SSA can effectively restore glenohumeral stability.
引用
收藏
页数:6
相关论文
共 50 条
[31]   Arthroscopic Technique for Distal Tibial Allograft Bone Augmentation With Suture Anchor Fixation for Anterior Shoulder Instability [J].
Tokish, John M. ;
Brinkman, Joseph C. ;
Hassebrock, Jeffrey D. .
ARTHROSCOPY TECHNIQUES, 2022, 11 (05) :E903-E909
[32]   Recurrent Shoulder Instability: Current Concepts for Evaluation and Management of Glenoid Bone Loss [J].
Provencher, Matthew T. ;
Bhatia, Sanjeev ;
Ghodadra, Neil S. ;
Grumet, Robert C. ;
Bach, Bernard R., Jr. ;
Dewing, Christopher B. ;
LeClere, Lance ;
Romeo, Anthony A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A :133-151
[33]   Comparison of Glenoid Bone Loss After Unidirectional Versus Combined Shoulder Instability in a Military Population [J].
Yoon, Annette H. ;
Sandler, Alexis B. ;
Scanaliato, John P. ;
Klahs, Kyle J. ;
Hurley, Eoghan T. ;
Tyler, John ;
Parnes, Nata .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (01)
[34]   Primary Distal Tibia Allograft for Restoration of Glenohumeral Stability with Anterior Glenoid Bone Loss [J].
Liles, Jordan L. ;
Ganokroj, Phob ;
Peebles, Annalise M. ;
Mologne, Mitchell S. ;
Provencher, Capt Matthew T. .
ARTHROSCOPY TECHNIQUES, 2022, 11 (06) :E1039-E1043
[35]   Allograft Reconstruction for Glenoid Bone Loss in Glenohumeral Instability: A Systematic Review [J].
Sayegh, Eli T. ;
Mascarenhas, Randy ;
Chalmers, Peter N. ;
Cole, Brian J. ;
Verma, Nikhil N. ;
Romeo, Anthony A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (12) :1642-1649
[36]   Mapping of glenoid bone loss in recurrent anterior shoulder instability: is there a particular deficit pattern? [J].
Bockmann, Benjamin ;
Venjakob, Arne Johannes ;
Reichwein, Frank ;
Hagenacker, Marthe ;
Nebelung, Wolfgang .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (09) :1676-1680
[37]   Risk Factors for Glenoid Bone Loss in the Setting of Posterior Glenohumeral Instability [J].
Green, Clare K. ;
Scanaliato, John P. ;
Sandler, Alexis B. ;
Wynkoop, Emily I. ;
Goldman, Adam ;
Turner, Robert C. ;
Czajkowski, Hunter ;
Rolf, Robert H. ;
Parnes, Nata .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (10)
[38]   Massive graft resorption after iliac crest allograft reconstruction for glenoid bone loss in recurrent anterior shoulder instability [J].
Elisabeth Boehm ;
Marvin Minkus ;
Philipp Moroder ;
Markus Scheibel .
Archives of Orthopaedic and Trauma Surgery, 2020, 140 :895-903
[39]   IODA-shoulder®, a 3-dimensional automated software for glenoid bone loss quantification in shoulder instability. A validation study [J].
Maiotti, Marco ;
De Nigris, Saverio ;
Tardioli, Stefano ;
Cavaliere, Massimo ;
Barilla, Santo ;
Angelini, Arianna ;
Torre, Guglielmo ;
Gauci, Marc Olivier .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2025, 111 (02)
[40]   Fresh Distal Tibial Allograft: An Updated Graft Preparation Technique for Anterior Shoulder Instability [J].
Liles, Jordan L. ;
Ganokroj, Phob ;
Peebles, Annalise M. ;
Mologne, Mitchell S. ;
Provencher, Capt Matthew T. .
ARTHROSCOPY TECHNIQUES, 2022, 11 (06) :E1027-E1031