Confocal microwave Imaging for breast cancer detection: Localization of tumors in three dimensions

被引:637
作者
Fear, EC
Li, X
Hagness, SC
Stuchly, MA
机构
[1] Univ Calgary, Calgary, AB T2N 1N4, Canada
[2] Univ Wisconsin, Madison, WI 53706 USA
[3] Univ Victoria, Victoria, BC V8W 3P6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
cancer; image reconstruction; microwave imaging; object detection;
D O I
10.1109/TBME.2002.800759
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The physical basis for breast tumor detection with microwave imaging is the contrast in dielectric properties of normal and malignant breast tissues. Confocal microwave imaging involves illuminating the breast with an ultra-wideband pulse from a number of antenna locations, then synthetically focusing reflections from the breast. The detection of malignant tumors is achieved by the coherent addition of returns from these strongly scattering objects. In this paper, we demonstrate the feasibility of detecting and localizing small (< 1 cm) tumors in three dimensions with numerical models of two system configurations involving synthetic cylindrical and planar antenna arrays. Image formation algorithms are developed to enhance tumor responses and reduce early- and late-time clutter. The early-time clutter consists of the incident pulse and reflections from the skin, while the late-time clutter is primarily due to the heterogeneity of breast tissue. Successful detection of 6-mm-diameter spherical tumors is achieved with both planar and cylindrical systems, and similar performance measures are obtained. The influences of the synthetic array size and position relative to the tumor are also explored.
引用
收藏
页码:812 / 822
页数:11
相关论文
共 31 条
  • [1] [Anonymous], 1986, Medical Applications of Microwave Imaging
  • [2] A PERFECTLY MATCHED LAYER FOR THE ABSORPTION OF ELECTROMAGNETIC-WAVES
    BERENGER, JP
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 1994, 114 (02) : 185 - 200
  • [3] Image restoration in chirp-pulse microwave CT (CP-MCT)
    Bertero, M
    Miyakawa, M
    Boccacci, P
    Conte, F
    Orikasa, K
    Furutani, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (05) : 690 - 699
  • [4] SCREENING MAMMOGRAPHY IN COMMUNITY PRACTICE - POSITIVE PREDICTIVE VALUE OF ABNORMAL FINDINGS AND YIELD OF FOLLOW-UP DIAGNOSTIC PROCEDURES
    BROWN, ML
    HOUN, F
    SICKLES, EA
    KESSLER, LG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1373 - 1377
  • [5] RECONSTRUCTION OF DIELECTRIC PERMITTIVITY DISTRIBUTIONS IN ARBITRARY 2-D INHOMOGENEOUS BIOLOGICAL BODIES BY A MULTIVIEW MICROWAVE NUMERICAL-METHOD
    CAORSI, S
    GRAGNANI, GL
    PASTORINO, M
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) : 232 - 239
  • [6] CHAUDHARY SS, 1984, INDIAN J BIOCHEM BIO, V21, P76
  • [7] Daniels D.J., 1996, Surface Penetrating Radar
  • [8] Ten-year risk of false positive screening mammograms and clinical breast examinations
    Elmore, G
    Barton, MB
    Moceri, VM
    Polk, S
    Arena, PJ
    Fletcher, SW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) : 1089 - 1096
  • [9] Microwave system for breast tumor detection
    Fear, EC
    Stuchly, MA
    [J]. IEEE MICROWAVE AND GUIDED WAVE LETTERS, 1999, 9 (11): : 470 - 472
  • [10] Microwave detection of breast tumors: comparison of skin subtraction algorithms
    Fear, EC
    Stuchly, MA
    [J]. SUBSURFACE SENSING TECHNOLOGIES AND APPLICATIONS II, 2000, 4129 : 207 - 217