Anchorage of Large-Diameter Reinforcing Bars in Ducts

被引:6
作者
Steuck, Kyle P. [1 ]
Eberhard, Marc O. [2 ]
Stanton, John F. [2 ]
机构
[1] Degenkolb Engineers, Seattle, WA USA
[2] Univ Washington, Seattle, WA 98195 USA
关键词
anchorage; bond; duct; joint; precast; reinforcement;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In precast concrete systems, connections are often made by grouting bars that project from one member into ducts embedded in another. For bridge bents, bar-duct systems can be assembled rapidly if a few large bars and ducts are used to connect the column and cap beam. In some cases, the required anchorage lengths for the large bars exceed the length available. To evaluate the anchorage requirements for this situation, 14 pullout tests were performed on bars with sizes up to No. 18. The tests and a nonlinear finite element model showed that, under conditions similar to those tested, large bars can develop their yield and fracture strengths in as few as six and 10 bar diameters, respectively. The effects of the bar size were found to be small compared to the scatter among the test results. Parallel tests with polypropylene fibers showed that fibers generally decreased pullout resistance, although this is likely the result of reduced grout strength.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 25 条
  • [11] *FHWA, 2007, ACC BRIDG CONSTR LIS
  • [12] HIEBER DG, 2005, 5941 WARD WASH STAT
  • [13] HIEBER DG, 2005, 6111 WARD WASH STAT
  • [14] Jirsa JO., 1979, CONCRETE INT, V1, P47
  • [15] Shear strength of Portland cement grout
    Moosavi, M
    Bawden, WF
    [J]. CEMENT & CONCRETE COMPOSITES, 2003, 25 (07) : 729 - 735
  • [16] An overview of the PRESSS five-story precast test building
    Nakaki, SD
    Stanton, JF
    Sritharan, S
    [J]. PCI JOURNAL, 1999, 44 (02): : 26 - +
  • [17] Orangun C.O., 1977, Journal Proceedings, V74, P114, DOI [10.14359/10993, DOI 10.14359/10993]
  • [18] *PCI, 2004, PCI DES HDB
  • [19] Raynor DJ, 2002, ACI STRUCT J, V99, P568
  • [20] Raynor DJ, 2000, Doctoral dissertation