Force transmission of one- and two-piece morse-taper oral implants:: a nonlinear finite element analysis

被引:32
作者
Çehreli, MC [1 ]
Akça, K [1 ]
Iplikçioglu, H [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
bone; force transfer; implant design; morse-taper; one-piece implant; two-piece implant;
D O I
10.1111/j.1600-0501.2004.01025.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare force transmission behaviors of one-piece (1-P) and two-piece (2-P) morse-taper oral implants. Material and methods: A three-dimensional finite element model of a morse-taper oral implant and a solid abutment was constructed separately. The implant-abutment complex was embedded in a O 1.5 cm x 1.5 cm acrylic resin cylinder. Vertical and oblique forces of 50 N and 100 N were applied on the abutment and solved by two different analyses. First, contact analysis was performed in the implant-abutment complex to evaluate a 2-P implant. Then, the components were bonded with a separation force of 10(20) N to analyze a 1-P implant. Results: Von Mises stresses in the implant, principal stresses, and displacements in the resin were the same for both designs under vertical loading. Under oblique loading, principal stresses and displacement values in the resin were the same, but the magnitudes of Von Mises stresses were higher in the 2-P implant. The principal stress distributions around both implants in the acrylic bone were similar under both loading conditions. Conclusion: 2-P implants experience higher mechanical stress under oblique loading. Nevertheless, the 1-P- or 2-P morse-taper nature of an implant is not a decisive factor for the magnitude and distribution of stresses, and displacements in supporting tissues.
引用
收藏
页码:481 / 489
页数:9
相关论文
共 31 条
  • [1] ABKOWITZ S, 1995, TITANIUM IND
  • [2] Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant -: A nonlinear finite element stress analysis
    Akça, K
    Çehreli, MC
    Iplikçioglu, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) : 444 - 454
  • [3] Akça K, 2002, INT J PROSTHODONT, V15, P115
  • [4] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [5] Branemark P I, 1999, Clin Implant Dent Relat Res, V1, P2, DOI 10.1111/j.1708-8208.1999.tb00086.x
  • [6] Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
  • [7] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [8] Buser D A, 1988, Int J Oral Maxillofac Implants, V3, P173
  • [9] Implant design and interface force transfer - A photoelastic and strain-gauge analysis
    Cehreli, M
    Duyck, J
    De Cooman, M
    Puers, R
    Naert, I
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) : 249 - 257
  • [10] Engquist B, 2002, CLIN ORAL IMPLAN RES, V13, P30