Soft X-ray response of the CCD camera (XIS)

被引:0
|
作者
Shouho, M
Katayama, H
Katayama, K
Kohmura, T
Tsunemi, H
Kitamoto, S
Hayashida, K
Miyata, E
Hashimotodani, K
Koyama, K
Ricker, G
Bautz, MW
Foster, R
Kissel, S
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Toyonaka, Osaka 5600043, Japan
[2] Kyoto Univ, Grad Sch Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
关键词
D O I
10.1002/1521-3994(199908)320:4/5<382::AID-ASNA382>3.0.CO;2-O
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Soft X-ray response of the CCD camera (XIS, X-ray Imaging Spectrometer), which will be aboard the Astro-E satellite, was investigated for the monochromatic;X-rays in the 0.25-2.2 keV. Detailed pulse-height distribution was examined particularly for O-K line, where significant low-energy tail was found. With the aid of Monte Carlo simulation we found that the photons absorbed in the channel stop was responsible for the component.
引用
收藏
页码:382 / 382
页数:1
相关论文
共 50 条
  • [1] Soft X-ray response of X-ray CCD camera XIS onboard Astro-E2
    Hayashida, K
    Torii, K
    Namiki, M
    Shiroshoji, T
    Shoji, M
    Katsuda, S
    Matsuura, D
    Miyauchi, T
    Tsunemi, H
    Kohmura, T
    Katayama, H
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 73 - 84
  • [2] Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band
    Katayama, H
    Shouho, M
    Kohmura, T
    Katayama, K
    Ohta, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    Doty, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 721 - 728
  • [3] Soft X-ray response of the proto-type CCD camera (XIS) for Astro-E
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Tsunemi, H
    Hashimotodani, K
    Katayama, K
    Kohmura, T
    Asakura, R
    Yoshita, K
    Katayama, H
    Shouho, M
    Koyoma, K
    Tsuru, TG
    Awaki, H
    Dotani, T
    Ozaki, M
    Ricker, G
    Doty, J
    Bautz, M
    Kissel, S
    Foster, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 278 - 290
  • [4] Reports of soft X-ray response of the engineering model of the CCD camera (XIS) for the ASTRO-E mission
    Katayama, K
    Kohmura, T
    Katayama, H
    Shouho, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Koyama, K
    Ricker, G
    Bautz, M
    Foster, R
    BROAD BAND X-RAY SPECTRA OF COSMIC SOURCES, 2000, 25 (3-4): : 881 - 884
  • [5] Quantum efficiency measurement of the X-ray CCD camera (XIS) for the ASTRO-E mission in the soft X-ray band
    Kohmura, T
    Katayama, K
    Katayama, H
    Shouho, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Ohtani, M
    Ohta, M
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 588 - 596
  • [6] The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector
    Nishiuchi, M
    Koyama, K
    Awaki, H
    Tsuru, T
    Sakano, M
    Hamaguchi, K
    Murakami, H
    Tsunemi, H
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Dotani, T
    Ozaki, M
    Bautz, M
    Doty, J
    Kissel, S
    Foster, R
    Ricker, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 79 - 84
  • [7] Hard X-ray response of the XIS-CCD for ASTRO-E: qualification of the X-ray CCD detector
    Nishiuchi, M.
    Koyama, K.
    Awaki, H.
    Tsuru, T.
    Sakano, M.
    Hamaguchi, K.
    Murakami, H.
    Tsunemi, H.
    Hayashida, K.
    Kitamoto, S.
    Miyata, E.
    Dotani, T.
    Ozaki, M.
    Bautz, M.
    Doty, J.
    Kissel, S.
    Foster, R.
    Ricker, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 79 - 84
  • [8] Soft X-ray response of the X-ray CCD camera directly coated with Optical Blocking Layer
    Ikeda, S.
    Kohmura, T.
    Kawai, K.
    Kaneko, K.
    Watanabe, T.
    Tsunemi, H.
    Hayashida, K.
    Anabuki, N.
    Nakajima, H.
    Ueda, S.
    Tsuru, T. G.
    Dotani, T.
    Ozaki, M.
    Matsuta, K.
    Fujinaga, T.
    Kitamoto, S.
    Murakami, H.
    Hiraga, J.
    Mori, K.
    SUZAKU 2011: EXPLORING THE X-RAY UNIVERSE: SUZAKU AND BEYOND, 2012, 1427
  • [9] Ground calibration of X-ray CCD camera XIS onboard ASTRO-E
    Tsuru, T
    Nishiuchi, H
    Awaki, H
    Hamaguchi, K
    Koyama, K
    Tomida, H
    Sakano, M
    BROAD BAND X-RAY SPECTRA OF COSMIC SOURCES, 2000, 25 (3-4): : 885 - 888
  • [10] Soft X-ray response of a CCD with a grating spectrometer
    Shouho, M
    Katayama, K
    Katayama, H
    Kohmura, T
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 85 - 90