A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [31] Effect of mini-implant length and diameter on primary stability under loading with two force levels
    Chatzigianni, Athina
    Keilig, Ludger
    Reimann, Susanne
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 381 - 387
  • [32] Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study
    Su, Li
    Song, Hui
    Huang, Xiaofeng
    BMC ORAL HEALTH, 2022, 22 (01)
  • [33] Orthodontic mini-implant diameter does not affect in-situ linear microcrack generation in the mandible or the maxilla
    Liu, Sean Shih-Yao
    Cruz-Marroquin, Enrique
    Sun, Jun
    Stewart, Kelton T.
    Allen, Matthew R.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (06) : 768 - 773
  • [34] Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures
    Cho, Il-Sik
    Baek, Sang-Ho
    Kim, Young Ho
    ANGLE ORTHODONTIST, 2013, 83 (06) : 1009 - 1014
  • [35] Impact of Implant Design and Bone Properties on the Primary Stability of Orthodontic Mini-Implants
    Redzepagic-Vrazalica, Lejla
    Mesic, Elmedin
    Pervan, Nedim
    Hadziabdic, Vahidin
    Delic, Muamer
    Glusac, Mirza
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 10
  • [36] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Manuel Nienkemper
    Benedict Wilmes
    Alexander Pauls
    Dieter Drescher
    Head & Face Medicine, 9
  • [37] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
    Jacek Matys
    Rafał Flieger
    Gianluca Tenore
    Kinga Grzech-Leśniak
    Umberto Romeo
    Marzena Dominiak
    Lasers in Medical Science, 2018, 33 : 489 - 495
  • [38] Accuracy of torque-limiting devices used for mini-implant placement-an in vitro study
    Pauls, Alexander
    Nienkemper, Manuel
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2013, 74 (02): : 124 - 136
  • [39] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [40] Accuracy of torque-limiting devices used for mini-implant placement-an in vitro study
    Pauls, Alexander
    Nienkemper, Manuel
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2013, 74 (02): : 124 - 136