A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [21] Influence of bone architecture on the primary stability of different mini-implant designs
    da Cunha, Amanda Carneiro
    Marquezan, Mariana
    Lima, Inaya
    Lopes, Ricardo Tadeu
    Nojima, Lincoln Issamu
    Sant'Anna, Eduardo Franzotti
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (01) : 45 - 51
  • [22] Factorial analysis of variables affecting bone stress adjacent to the orthodontic anchorage mini-implant with finite element analysis
    Lin, Ting-Sheng
    Tsai, Feng-De
    Chen, Chih-Yu
    Lin, Li-Wen
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (02) : 182 - 189
  • [23] Quantitative assessment of orthodontic mini-implant displacement: The effect of initial force application
    Holst, Alexandra Ioana
    Karl, Matthias
    Karolczak, Marek
    Goellner, Matthias
    Holst, Stefan
    QUINTESSENCE INTERNATIONAL, 2010, 41 (01): : 59 - 66
  • [24] Optimal selections of orthodontic mini-implant diameter and length by biomechanical consideration: A three-dimensional finite element analysis
    Jiang, Lin
    Kong, Liang
    Li, Tao
    Gu, Zexu
    Hou, Rui
    Duan, Yinzhong
    ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (11) : 1124 - 1130
  • [25] Orthodontic mini-implant stability in different healing times before loading: A microscopic computerized tomographic and biomechanical analysis
    Zhao, Lixing
    Xu, Zhenrui
    Yang, Zhi
    Wei, Xing
    Tang, Tian
    Zhao, Zhihe
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02): : 196 - 202
  • [26] A healing period increases mini-implant stability in growing rats
    Yano, Shinya
    Motoyoshi, Mitsuru
    Inaba, Mizuki
    Yano, Saori
    Takenouchi, Hiroyuki
    Son, Seil
    Arai, Yoshinori
    Shimizu, Noriyoshi
    JOURNAL OF ORAL SCIENCE, 2014, 56 (02) : 113 - 118
  • [27] Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure
    Heo, Yoon-Young
    Cho, Keun-Chul
    Baek, Seung-Hak
    ANGLE ORTHODONTIST, 2012, 82 (05) : 881 - 888
  • [28] Horizontal Pull-Out Strength of Orthodontic Infrazygomatic Mini-Implant: An In Vitro Study
    Chen, Chun-Ming
    Wu, Ju-Hui
    Lu, Pei-Chen
    Wang, Huang-Chi
    Lee, Huey-Er
    Wang, Chau-Hsiang
    Du, Je-Kang
    IMPLANT DENTISTRY, 2011, 20 (02) : 139 - 145
  • [29] Primary stability and viscoelastic displacement of mini-implant system under loading
    Lee, Jim
    Jeong, Yong-Hoon
    Pittman, Joseph
    Deguchi, Toru
    Johnston, William M.
    Fields, Henry W.
    Kim, Do-Gyoon
    CLINICAL BIOMECHANICS, 2017, 41 : 28 - 33
  • [30] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495