A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [11] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shen, Shuning
    Sun, Yingying
    Zhang, Chen
    Yang, Yongjin
    Li, Zhiren
    Cai, Xingwei
    Duan, Yinzhong
    Li, Tao
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 109 - 116
  • [12] Effects of Different Angulation Placement of Mini-Implant in Orthodontic
    Omar, Aisyah
    Ishak, Muhammad Ikman
    Harun, Muhamad Noor
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 1214 - +
  • [13] A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device
    Hosein, Yara K.
    Dixon, S. Jeffrey
    Rizkalla, Amin S.
    Tassi, Ali
    ANGLE ORTHODONTIST, 2019, 89 (02) : 284 - 291
  • [14] Effects of Drilling Technology on Mini-Implant Primary Stability: A Comparison of the Mechanical Drilling and Femtosecond Laser Ablation
    Zhang, Wenbin
    Alghannam, Fahad
    Zhu, Yingchao
    Zhang, Jianfei
    Wohl, Gregory R.
    Haugen, Harold K.
    Qin, Zhipeng
    Xie, Guoqiang
    Fang, Qiyin
    Shen, Steve Guofang
    FRONTIERS IN PHYSICS, 2021, 9
  • [15] Effects of surface treatment on the osseointegration potential of orthodontic mini-implant
    Jeon, Mi-Sun
    Kang, Yoon-Goo
    Mo, Sung-Seo
    Lee, Keun-Hye
    Kook, Yoon-Ah
    Kim, Seong-Hun
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (05) : 328 - 336
  • [16] The impact of healing time before loading on orthodontic mini-implant stability: A histomorphometric study in minipigs
    Oltramari-Navarro, Paula V. P.
    Navarro, Ricardo L.
    Henriques, Jose Fernando C.
    Cestari, Tania M.
    Francischone, Carlos E.
    Taga, Rumio
    McNamara, James A., Jr.
    ARCHIVES OF ORAL BIOLOGY, 2013, 58 (07) : 806 - 812
  • [17] The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study
    Cho, Il-Sik
    Choo, HyeRan
    Kim, Seong-Kyun
    Shin, Yun-Seob
    Kim, Duck-Su
    Kim, Seong-Hun
    Chung, Kyu-Rhim
    Huang, John C.
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05): : 354 - 360
  • [18] Outcome of orthodontic mini-implant loss in relation to interleukin 6 polymorphisms
    Reichow, A. M.
    Melo, A. C.
    de Souza, C. M.
    Castilhos, B. B.
    Olandoski, M.
    Alvim-Pereira, C. C. K.
    Alvim-Pereira, F.
    Trevilatto, P. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (05) : 649 - 657
  • [19] Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading
    Lee, Yang-Ku
    Kim, Jong-Wan
    Baek, Seung-Hak
    Kim, Tae-Woo
    Chang, Young-Il
    ANGLE ORTHODONTIST, 2010, 80 (03) : 452 - 458
  • [20] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Nienkemper, Manuel
    Wilmes, Benedict
    Pauls, Alexander
    Drescher, Dieter
    HEAD & FACE MEDICINE, 2013, 9