Noninvasive Hypoxia Monitor Based on Gene-Free Engineering of Lactate Oxidase for Analysis of Undiluted Sweat

被引:64
作者
Pribil, Medeya M. [1 ]
Laptev, Gennady U. [1 ]
Karyakina, Elena E. [1 ]
Karyakin, Arkady A. [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Fac Chem, Moscow 119991, Russia
关键词
PRUSSIAN BLUE; AMPEROMETRIC DETERMINATION; ANAEROBIC THRESHOLD; BLOOD LACTATE; BIOSENSOR; ELECTRODE; IMMOBILIZATION; GLUCOSE; IMPROVEMENT; TRANSDUCER;
D O I
10.1021/ac501547u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the Prussian Blue based lactate biosensor with the remarkably increased upper detection limit suitable for analysis of undiluted sweat. Engineering of the enzyme lactate oxidase has been carried out upon its immobilization from water isopropanol mixtures with the high (90%) content of organic solvent. To decrease the enzyme binding constant, we propose to shield the substrate binding sites in its active center with negatively charged polyelectrolyte. The biosensor made from the optimal mixture (3% gamma- aminopropyltriethoxysilane and 5% perfluorosulfonated ionomer) is characterized by the calibration graph, which even in batch mode is shifted for 2 orders of magnitude toward high analyte concentrations as compared to it of lactate sensitive electrode made without Nafion analogue. In flow-injection mode, the biosensor allows lactate detection up to 0.5 M. The biosensor displays stable response for 4 h of continuous operation. The achieved analytical performance characteristics allow the monitoring of lactate content in undiluted sweat. A successful validation of the elaborated flow-through monitor with the integrated biosensor opens new horizons for noninvasive diagnostics of hypoxia-related conditions.
引用
收藏
页码:5215 / 5219
页数:5
相关论文
共 36 条
[1]   Serial blood lactate levels can predict the development of multiple organ failure following septic shock [J].
Bakker, J ;
Gris, P ;
Coffernils, M ;
Kahn, RJ ;
Vincent, JL .
AMERICAN JOURNAL OF SURGERY, 1996, 171 (02) :221-226
[2]  
BROOKS GA, 1985, MED SCI SPORT EXER, V17, P22
[3]   An exercise degree monitoring biosensor based on electrochemiluminescent detection of lactate in sweat [J].
Cai, Xia ;
Yan, Jilin ;
Chu, Haihong ;
Wu, Meisheng ;
Tu, Yifeng .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) :655-659
[4]   Lactate Threshold Concepts How Valid are They? [J].
Faude, Oliver ;
Kindermann, Wilfried ;
Meyer, Tim .
SPORTS MEDICINE, 2009, 39 (06) :469-490
[5]   Sweat lactate response between males with high and low aerobic fitness [J].
Green, JM ;
Pritchett, RC ;
Crews, TR ;
McLester, JR ;
Tucker, DC .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (01) :1-6
[6]   ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
GUILBAULT, GG ;
LUBRANO, GJ .
ANALYTICA CHIMICA ACTA, 1973, 64 (03) :439-455
[7]   IMMOBILIZATION OF LACTATE OXIDASE IN A POLY(VINYL ALCOHOL) MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY CHEMICAL CROSS-LINKING WITH ISOCYANATE [J].
HAJIZADEH, K ;
HALSALL, HB ;
HEINEMAN, WR .
TALANTA, 1991, 38 (01) :37-47
[8]   An amperometric lactate biosensor using H2O2 reduction via a Prussian Blue impregnated poly(ethyleneimine) surface on screen printed carbon electrodes to detect anastomotic leak and sepsis [J].
Hirst, N. A. ;
Hazelwood, L. D. ;
Jayne, D. G. ;
Millner, P. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 :674-680
[9]   BLOOD LACTATE - IMPLICATIONS FOR TRAINING AND SPORTS PERFORMANCE [J].
JACOBS, I .
SPORTS MEDICINE, 1986, 3 (01) :10-25
[10]   Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration [J].
Jia, Wenzhao ;
Bandodkar, Amay J. ;
Valdes-Ramirez, Gabriela ;
Windmiller, Joshua R. ;
Yang, Zhanjun ;
Ramirez, Julian ;
Chan, Garrett ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2013, 85 (14) :6553-6560