Online Built-In Self-Test of High Switching Frequency DC-DC Converters Using Model Reference Based System Identification Techniques

被引:28
作者
Beohar, Navankur [1 ]
Malladi, Venkata N. K. [2 ,3 ]
Mandal, Debashis [1 ]
Ozev, Sule [1 ]
Bakkaloglu, Bertan [1 ]
机构
[1] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ 85287 USA
[2] Arizona State Univ, Tempe, AZ 85287 USA
[3] NXP Semicond, SOI CMOS & GaAs Proc, Chandler, AZ 85224 USA
关键词
Analog BIST; DC-DC power converters; frequency response; impulse response; parameter estimation; pulse width modulation (PWM); switched capacitor; white noise; POWER CONVERTERS; DIGITAL CONTROLLERS; DOMAIN;
D O I
10.1109/TCSI.2017.2739479
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A built-in self-test (BIST) technique that enables tracking of loop parameters of integrated DC-DC converters without affecting the normal mode of operation is presented. A digital pseudo-noise based stimulus and a mixed signal cross-correlation based analysis technique is used to derive on-chip impulse response, with minimum computational requirements in comparison to a digital correlator approach. Using measured impulse response, open-loop phase margin and closed-loop unity-gain frequency are estimated within 5.2% and 4.1% error, respectively, for the load current range of 30 mA to 200 mA. Converter parameters, such as natural frequency, Q-factor, and center frequency are estimated within 3.6%, 4.7%, and 3.8% error, respectively, over load inductance of 4.7 mu H to 10.3 mu H, and filter capacitance of 200 nF to 400 nF. A 5 MHz switching frequency, 5 V to 8.125 V input voltage range, voltage-mode controlled DC-DC buck converter is designed for the proposed model reference based parametric and non-parametric BIST analysis. The converter output voltage range is 3.3 V to 5 V and supported maximum load current is 450 mA with a peak efficiency of 87.93%. The proposed converter is fabricated on a 0.6 mu m 6 layer-metal SOI technology with a die area of 9 mm(2). The system identification circuitry occupies 3.8% of the converter area with 530 mu A quiescent current during operation.
引用
收藏
页码:818 / 831
页数:14
相关论文
共 42 条
[1]   Use of a priori information in the identification of global nonlinear models -: A case study using a buck converter [J].
Aguirre, LA ;
Donoso-Garcia, PF ;
Santos, R .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2000, 47 (07) :1081-1085
[2]   Active Online System Identification of Switch Mode DC-DC Power Converter Based on Efficient Recursive DCD-IIR Adaptive Filter [J].
Algreer, Maher ;
Armstrong, Matthew ;
Giaouris, Damian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (11) :4425-4435
[3]  
[Anonymous], P IEEE 26 POW EL SPE
[4]  
[Anonymous], 1999, SYSTEM IDENTIFICATIO
[5]   ADAPTIVE FEEDBACK-CONTROL [J].
ASTROM, KJ .
PROCEEDINGS OF THE IEEE, 1987, 75 (02) :185-217
[6]   Improved Online Identification of a DC-DC Converter and Its Control Loop Gain Using Cross-Correlation Methods [J].
Barkley, Adam ;
Santi, Enrico .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :2021-2031
[7]  
Barragán LA, 2012, APPL POWER ELECT CO, P1218, DOI 10.1109/APEC.2012.6165974
[8]  
Beohar N, 2015, IEEE VLSI TEST SYMP, DOI 10.1109/VTS.2015.7116250
[9]   Online Frequency Response Analysis: A Powerful Plug-in Tool for Compensation Design and Health Assessment of Digitally Controlled Power Converters [J].
Bhardwaj, Manish ;
Choudhury, Shamim ;
Poley, R. ;
Akin, Bilal .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (03) :2426-2435
[10]  