Quantification of Peptide m/z Distributions from 13C-Labeled Cultures with High-Resolution Mass Spectrometry

被引:14
|
作者
Allen, Doug K. [1 ]
Goldford, Joshua [2 ]
Gierse, James K. [1 ]
Mandy, Dominic [2 ]
Diepenbrock, Christine [1 ]
Libourel, Igor G. L. [2 ]
机构
[1] ARS, Plant Genet Res Unit, USDA, Donald Danforth Plant Sci Ctr, St Louis, MO 63132 USA
[2] Univ Minnesota, Dept Plant Biol, St Paul, MN 55108 USA
基金
美国国家科学基金会;
关键词
METABOLIC FLUX ANALYSIS; ISOTOPIC ABUNDANCE MEASUREMENTS; AMINO-ACIDS; CELL-CULTURE; PROTEOMICS; ACCURACY; C-13; PROTEINS; SYSTEMS; DESIGN;
D O I
10.1021/ac403985w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotopic labeling studies of primary metabolism frequently utilize GC/MS to quantify C-13 in protein-hydrolyzed amino acids. During processing some amino acids are degraded, which reduces the size of the measurement set. The advent of high-resolution mass spectrometers provides a tool to assess molecular masses of peptides with great precision and accuracy and computationally infer information about labeling in amino acids. Amino acids that are isotopically labeled during metabolism result in labeled peptides that contain spatial and temporal information that is associated with the biosynthetic origin of the protein. The quantification of isotopic labeling in peptides can therefore provide an assessment of amino acid metabolism that is specific to subcellular, cellular, or temporal conditions. A high-resolution orbital trap was used to quantify isotope labeling in peptides that were obtained from unlabeled and isotopically labeled soybean embryos and Escherichia coli cultures. Standard deviations were determined by estimating the multinomial variance associated with each element of the m/z distribution. Using the estimated variance, quantification of the m/z distribution across multiple scans was achieved by a nonlinear fitting approach. Observed m/z distributions of uniformly labeled E. coli peptides indicated no significant differences between observed and simulated m/z distributions. Alternatively, amino acid m/z distributions obtained from GC/MS were convolved to simulate peptide m/z distributions but resulted in distinct profiles due to the production of protein prior to isotopic labeling. The results indicate that peptide mass isotopologue measurements faithfully represent mass distributions, are suitable for quantification of isotope-labeling-based studies, and provide additional information over existing methods.
引用
收藏
页码:1894 / 1901
页数:8
相关论文
共 43 条
  • [1] Highlighting the tricarboxylic acid cycle: Liquid and gas chromatography-mass spectrometry analyses of 13C-labeled organic acids
    Koubaa, Mohamed
    Cocuron, Jean-Christophe
    Thomasset, Brigitte
    Alonso, Ana Paula
    ANALYTICAL BIOCHEMISTRY, 2013, 436 (02) : 151 - 159
  • [2] Metabolism of 13C-Labeled Fatty Acids in Term Human Placental Explants by Liquid Chromatography-Mass Spectrometry
    Watkins, Oliver C.
    Islam, Mohammad Omedul
    Selvam, Preben
    Pillai, Reshma Appukuttan
    Cazenave-Gassiot, Amaury
    Bendt, Anne K.
    Karnani, Neerja
    Godfrey, Keith M.
    Lewis, Rohan M.
    Wenk, Markus R.
    Chan, Shiao-Yng
    ENDOCRINOLOGY, 2019, 160 (06) : 1394 - 1408
  • [3] Assessment of meat authenticity using bioinformatics, targeted peptide biomarkers and high-resolution mass spectrometry
    Orduna, Alberto Ruiz
    Husby, Erik
    Yang, Charles T.
    Ghosh, Dipankar
    Beaudry, Francis
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (10): : 1709 - 1717
  • [4] Investigating the utility of minimized sample preparation and high-resolution mass spectrometry for quantification of monoclonal antibody drugs
    Nguyen, Tam T. T. N.
    Mistarz, Ulrik H.
    Costa, Narciso
    Herbet, Amaury
    Boquet, Didier
    Becher, Francois
    Rand, Kasper D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 384 - 392
  • [5] SWATH Tandem Mass Spectrometry Workflow for Quantification of Mass Isotopologue Distribution of Intracellular Metabolites and Fragments Labeled with Isotopic 13C Carbon
    Jaiswal, Damini
    Prasannan, Charulata B.
    Hendry, John I.
    Wangikar, Pramod P.
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6486 - 6493
  • [6] Analysis of 13C labeling amino acids by capillary electrophoresis - High resolution mass spectrometry in developing flaxseed
    Acket, Sebastien
    Degournay, Anthony
    Gosset, Mathilde
    Merlier, Franck
    Troncoso-Ponce, Manual Adrian
    Thomasset, Brigitte
    ANALYTICAL BIOCHEMISTRY, 2018, 547 : 14 - 18
  • [7] Peptide Selection for Accurate Targeted Protein Quantification via a Dimethylation High-Resolution Mass Spectrum Strategy with a Peptide Release Kinetic Model
    Chen, Qi
    Jiang, Yirong
    Ren, Yiping
    Ying, Meirong
    Lu, Baiyi
    ACS OMEGA, 2020, 5 (08): : 3809 - 3819
  • [8] Comprehensive workflow encompassing discovery, verification, and quantification of indicator peptide in snail mucin using LC-quadrupole Orbitrap high-resolution tandem mass spectrometry
    Moon, Sung -Kwon
    Jeong, Eun-Jin
    Tonog, Genevieve
    Jin, Cheng-Min
    Lee, Jeong-seok
    Kim, Hoon
    FOOD RESEARCH INTERNATIONAL, 2024, 180
  • [9] Multiplex Quantification of Protein Toxins in Human Biofluids and Food Matrices Using Immunoextraction and High-Resolution Targeted Mass Spectrometry
    Dupre, Mathieu
    Gilquin, Benoit
    Fenaille, Francois
    Feraudet-Tarisse, Cecile
    Dano, Julie
    Ferro, Myriam
    Simon, Stephanie
    Junot, Christophe
    Brun, Virginie
    Becher, Francois
    ANALYTICAL CHEMISTRY, 2015, 87 (16) : 8473 - 8480
  • [10] LILY-lipidome isotope labeling of yeast: in vivo synthesis of 13C labeled reference lipids for quantification by mass spectrometry
    Rampler, Evelyn
    Coman, Cristina
    Hermann, Gerrit
    Sickmann, Albert
    Ahrends, Robert
    Koellensperger, Gunda
    ANALYST, 2017, 142 (11) : 1891 - 1899