In Situ Ammonium Profiling Using Solid-Contact Ion-Selective Electrodes in Eutrophic Lakes

被引:56
作者
Athavale, Rohini [1 ,5 ]
Kokorite, Ilga [1 ,2 ,3 ]
Dinkel, Christian [1 ]
Bakker, Eric [4 ]
Wehrli, Bernhard [1 ,5 ]
Crespo, Gaston A. [4 ]
Brand, Andreas [1 ,5 ]
机构
[1] Eawag Swiss Fed Inst Aquat Sci & Technol, Dept Surface Waters Res & Management, CH-6047 Kastanienbaum, Switzerland
[2] Univ Latvia, Fac Geog & Earth Sci, LV-1004 Riga, Latvia
[3] Univ Latvia, Inst Biol, LV-2169 Salaspils, Latvia
[4] Univ Geneva, Dept Inorgan & Analyt Chem, CH-1211 Geneva, Switzerland
[5] ETH, Inst Biogeochem & Pollutant Dynam, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
POTENTIOMETRIC SENSORS; CONDUCTING POLYMERS; CARBON NANOTUBES; WATERS; LAYER;
D O I
10.1021/acs.analchem.5b02424
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A promising profiling setup for in situ measurements in lakes with potentiometric solid-contact ion-selective electrodes (SC-ISEs) and a data processing method for sensor calibration and drift correction are presented. The profiling setup consists of a logging system, which is equipped with a syringe sampler and sensors for the measurement of standard parameters including temperature, conductivity, oxygen and photosynthetically active radiation (PAR). The setup was expanded with SC-ISEs in galvanically separated amplifiers. The potential for high-resolution profiling is investigated by deploying the setup in the eutrophic Lake Rotsee (Lucerne, Switzerland), using two different designs of ammonium sensing SC-ISEs. Ammonium was chosen as a target analyte, since it is the most common reduced inorganic nitrogen species involved in various pathways of the nitrogen cycle and is therefore indicative of numerous biogeochemical processes that occur in lakes such as denitrification and primary production. One of the designs, which uses a composite carbonnanotube PVC-based membrane, suffered from sulfide poisoning in the deeper, sulfidic regions of the lake. In contrast, electrodes containing a plasticizer-free methacrylate copolymer-based sensing layer on top of a conducting polymer layer as a transducer did not show this poisoning effect. The syringe samples drawn during continuous profiling were utilized to calibrate the electrode response. Reaction hotspots and steep gradients of ammonium concentrations were identified on-site by monitoring the electrode potential online. Upon conversion to high-resolution concentration profiles, fine scale features between the calibration points were displayed, which would have been missed by conventional limnological sampling and subsequent laboratory analyses. Thus, the presented setup with SC-ISEs tuned to analytes of interest can facilitate the study of biogeochemical processes that occur at the centimeter scale.
引用
收藏
页码:11990 / 11997
页数:8
相关论文
共 39 条
  • [1] Selectivity of potentiometric ion sensors
    Bakker, E
    Pretsch, E
    Bühlmann, P
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (06) : 1127 - 1133
  • [2] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [3] Modern Potentiometry
    Bakker, Eric
    Pretsch, Ernoe
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) : 5660 - 5668
  • [4] Bende-Michl U, 2010, J ENVIRON MONITOR, V12, P127, DOI [10.1039/b910156j, 10.1039/0110156j, 10.1039/B910156J]
  • [5] Understanding harmful algae in stratified systems: Review of progress and future directions
    Berdalet, E.
    McManus, M. A.
    Ross, O. N.
    Burchard, H.
    Chavez, F. P.
    Jaffe, J. S.
    Jenkinson, I. R.
    Kudela, R.
    Lips, I.
    Lips, U.
    Lucas, A.
    Rivas, D.
    Ruiz-de la Torre, M. C.
    Ryan, J.
    Sullivan, J. M.
    Yamazaki, H.
    [J]. DEEP-SEA RESEARCH PART II-TOPICAL STUDIES IN OCEANOGRAPHY, 2014, 101 : 4 - 20
  • [6] Potentiometric ion sensors based on conducting polymers
    Bobacka, J
    Ivaska, A
    Lewenstam, A
    [J]. ELECTROANALYSIS, 2003, 15 (5-6) : 366 - 374
  • [7] Potentiometric ion sensors
    Bobacka, Johan
    Ivaska, Ari
    Lewenstam, Andrzej
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 329 - 351
  • [8] Solid contact potentiometric sensors for trace level measurements
    Chumbimuni-Torres, KY
    Rubinova, N
    Radu, A
    Kubota, LT
    Bakker, E
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1318 - 1322
  • [9] SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN SULFIDE IN NATURAL WATERS
    CLINE, JD
    [J]. LIMNOLOGY AND OCEANOGRAPHY, 1969, 14 (03) : 454 - &
  • [10] Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers
    Crespo, Gaston A.
    Macho, Santiago
    Xavier Rius, F.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (04) : 1316 - 1322