Ultra-Low Field NMR of UF6 for 235U Detection and Characterization

被引:7
|
作者
Magnelind, Per E. [1 ]
Matlashov, Andrei N. [1 ]
Volegov, Petr L. [1 ]
Espy, Michelle A. [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
SQUID; ULF-NMR; uranium hexafluoride; MICROTESLA MAGNETIC-FIELDS; MRI; RELAXATION;
D O I
10.1109/TASC.2009.2019562
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have demonstrated the first ultra-low field (ULF) nuclear magnetic resonance measurements of uranium hexafluoride (UF6), which is used in the uranium enrichment process. A sensitive non-invasive detection system would have an important role in non-proliferation surveillance. A two-frequency technique was employed to remove the transients induced by rapidly switching off the 50 mT pre-polarization field. A mean transverse relaxation time T-2 of 24 ms was estimated for the un-enriched UF6 sample measured at a mean temperature of 80 degrees C.
引用
收藏
页码:816 / 818
页数:3
相关论文
共 17 条
  • [1] Effect of (UF6)-U-235-(UF6)-U-238 gas mixing on the kinetic rate of the isotope exchange reaction between U-235-enriched UF5 nanoparticles and natural UF6 gas
    Kuga, Y
    Onoe, J
    Isomura, S
    Takeuchi, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1996, 33 (11) : 889 - 891
  • [2] Application of the 226Ra–230Th–234U and 227Ac–231Pa–235U radiochronometers to UF6 cylinders
    John M. Rolison
    Ross W. Williams
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 317 : 897 - 905
  • [3] A note on the inhibition of the isotope exchange reaction between 235U-enriched UF5 nanoparticles and natural UF6 gas
    Onoe, J
    Kuga, Y
    Takeuchi, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1999, 36 (01) : 108 - 109
  • [4] The Effect of Low Frequency External Field Disturbance on the SQUID Based Ultra-Low Field NMR Measurements
    Jin, Y. R.
    Wang, N.
    Li, S.
    Tian, Y.
    Ren, Y. F.
    Wu, Y. L.
    Deng, H.
    Chen, Y. F.
    Li, J.
    Tian, H. Y.
    Chen, G. H.
    Zheng, D. N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 518 - 521
  • [5] Application of Ultra-Low Field HTS-SQUID NMR/MRI to Contaminant Detection in Food
    Hatsukade, Y.
    Abe, T.
    Tsunaki, S.
    Yamamoto, M.
    Murata, H.
    Tanaka, S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [6] Application of the 226Ra-230Th-234U and 227Ac-231Pa-235U radiochronometers to UF6 cylinders
    Rolison, John M.
    Williams, Ross W.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 317 (02) : 897 - 905
  • [7] SQUID-based simultaneous detection of NMR and biomagnetic signals at ultra-low magnetic fields
    Espy, MA
    Matlachov, AN
    Volegov, PL
    Mosher, JC
    Kraus, RH
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 635 - 639
  • [8] Progress on Detection of Liquid Explosives Using Ultra-Low Field MRI
    Espy, Michelle
    Baguisa, Shermiyah
    Dunkerley, David
    Magnelind, Per
    Matlashov, Andrei
    Owens, Tuba
    Sandin, Henrik
    Savukov, Igor
    Schultz, Larry
    Urbaitis, Algis
    Volegov, Petr
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 530 - 533
  • [9] Strong pulsed excitations using circularly polarized fields for ultra-low field NMR
    Shim, Jeong Hyun
    Lee, Seong-Joo
    Yu, Kwon-Kyu
    Hwang, Seong-Min
    Kim, Kiwoong
    JOURNAL OF MAGNETIC RESONANCE, 2014, 239 : 87 - 90
  • [10] Low-Noise Pulsed Pre-Polarization Magnet Systems for Ultra-Low Field NMR
    Sims, James R.
    Schillig, Josef B.
    Swenson, Charles A.
    Gardner, David L.
    Matlashov, Andrei N.
    Ammerman, Curtt N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 752 - 755