Steady and unsteady state thermal behaviour of triple concentric-tube heat exchanger

被引:8
作者
Boultif, Nora [1 ]
Bougriou, Cherif [2 ]
机构
[1] Univ Biskra, Dept Mech Engn, LGEM, Fac Technol, BP 145, Biskra 07000, Algeria
[2] Univ Batna, Fac Technol, LESEI, Dept Mech Engn, 2 Rue M Boukhlouf, Batna 05000, Algeria
关键词
TRANSFER COEFFICIENTS; THEORETICAL-ANALYSIS; TEMPERATURE; PERFORMANCE; DROP;
D O I
10.1007/s00231-016-1859-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a numerical analysis by using the finite difference method to describe the steady and unsteady state thermal behavior of triple concentric-tube heat exchanger with parallel flow and counter flow arrangements. One gives the temperature variations of the three fluids and three walls with time along the triple concentric-tube heat exchanger. The fluids have a time lag and the response of triple concentric-tube heat exchanger in parallel flow configuration is faster than those of a counterflow arrangement, its performances are always lower than those of a counterflow triple concentric-tube heat exchanger. The heat transfer coefficients by convection of the three fluids vary with time in addition to the temperature and the heat exchanger performances are lower in unsteady state than the steady state case.
引用
收藏
页码:849 / 863
页数:15
相关论文
共 24 条
[1]  
Aldous DD, 1966, THESIS
[2]   Calculation of overall heat transfer coefficients in a triple tube heat exchanger [J].
Batmaz, E ;
Sandeep, KP .
HEAT AND MASS TRANSFER, 2005, 41 (03) :271-279
[3]   Overall heat transfer coefficients and axial temperature distribution in a triple tube heat exchanger [J].
Batmaz, Ediz ;
Sandeep, K. P. .
JOURNAL OF FOOD PROCESS ENGINEERING, 2008, 31 (02) :260-279
[4]  
Behera V.M., 2014, INT J SCI ENG RES, V5, P1226, DOI [10.21817/ijet/2016/v8i5/160805436, DOI 10.21817/IJET/2016/V8I5/160805436]
[5]   An analytical method for determining transient temperature field in a parallel-flow three-fluid heat exchanger [J].
Bielski, S ;
Malinowski, L .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (08) :1034-1044
[6]  
El Wakil N, 1995, EUROTHERM SEMINAR, V46, P141
[7]   Empirical correlation for the time lag of double pipe heat exchanger operating with variable flow rates [J].
Guellal, M. ;
Abdesselm, H. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) :970-976
[8]  
Kakc S., 1987, Handbook of single-phase convective heat transfer
[9]  
MORLEY TB, 1933, ENGINEER, V155, P134
[10]   Improved milk fouling simulation in a helical triple tube heat exchanger [J].
Nema, P. K. ;
Datta, A. K. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (19-20) :3360-3370