Accuracy of pedicle screw placement comparing robot-assisted technology and the free-hand with fluoroscopy-guided method in spine surgery: An updated meta-analysis

被引:76
作者
Fan, Yong [1 ]
Du, Jin Peng [1 ,2 ]
Liu, Ji Jun [1 ]
Zhang, Jia Nan [1 ]
Qiao, Huan Huan [3 ]
Liu, Shi Chang [1 ]
Hao, Ding Jun [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Honghui Hosp, Dept Spine Surg, Youyidong Rd, Xian 710000, Shaanxi, Peoples R China
[2] Yanan Univ, Med Coll, Yanan, Peoples R China
[3] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopead, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
fluoroscopy-guided; free-hand; pedicle screw; robot; spine surgery; GUIDANCE-SYSTEM; LUMBAR SPINE; INSERTION;
D O I
10.1097/MD.0000000000010970
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:A miniature spine-mounted robot has recently been introduced to further improve the accuracy of pedicle screw placement in spine surgery. However, the differences in accuracy between the robotic-assisted (RA) technique and the free-hand with fluoroscopy-guided (FH) method for pedicle screw placement are controversial. A meta-analysis was conducted to focus on this problem.Methods:Several randomized controlled trials (RCTs) and cohort studies involving RA and FH and published before January 2017 were searched for using the Cochrane Library, Ovid, Web of Science, PubMed, and EMBASE databases. A total of 55 papers were selected. After the full-text assessment, 45 clinical trials were excluded. The final meta-analysis included 10 articles.Results:The accuracy of pedicle screw placement within the RA group was significantly greater than the accuracy within the FH group (odds ratio 95%, perfect accuracy confidence interval: 1.38-2.07, P<.01; odds ratio 95% clinically acceptable Confidence Interval: 1.17-2.08, P<.01).Conclusions:There are significant differences in accuracy between RA surgery and FH surgery. It was demonstrated that the RA technique is superior to the conventional method in terms of the accuracy of pedicle screw placement.
引用
收藏
页数:7
相关论文
共 24 条
[1]   Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review [J].
Aoude, Ahmed A. ;
Fortin, Maryse ;
Figueiredo, Rainer ;
Jarzem, Peter ;
Ouellet, Jean ;
Weber, Michael H. .
EUROPEAN SPINE JOURNAL, 2015, 24 (05) :990-1004
[2]   Robotic assisted spine surgery - a breakthrough or a surgical toy? [J].
Barzilay, Y. ;
Kaplan, L. ;
Libergall, M. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (03) :195-196
[3]   Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot Retrospective Study [J].
Devito, Dennis P. ;
Kaplan, Leon ;
Dietl, Rupert ;
Pfeiffer, Michael ;
Horne, Dale ;
Silberstein, Boris ;
Hardenbrook, Mitchell ;
Kiriyanthan, George ;
Barzilay, Yair ;
Bruskin, Alexander ;
Sackerer, Dieter ;
Alexandrovsky, Vitali ;
Stueer, Carsten ;
Burger, Ralf ;
Maeurer, Johannes ;
Gordon, Donald G. ;
Schoenmayr, Robert ;
Friedlander, Alon ;
Knoller, Nachshon ;
Schmieder, Kirsten ;
Pechlivanis, Ioannis ;
Kim, In-Se ;
Meyer, Bernhard ;
Shoham, Moshe .
SPINE, 2010, 35 (24) :2109-2115
[4]   Accuracy of Pedicle Screw Placement With Robotic Guidance System A Cadaveric Study [J].
Fujishiro, Takashi ;
Nakaya, Yoshiharu ;
Fukumoto, Shingo ;
Adachi, Shu ;
Nakano, Atsushi ;
Fujiwara, Kenta ;
Baba, Ichiro ;
Neo, Masashi .
SPINE, 2015, 40 (24) :1882-1889
[5]   What Is the Learning Curve for Robotic-assisted Pedicle Screw Placement in Spine Surgery? [J].
Hu, Xiaobang ;
Lieberman, Isador H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (06) :1839-1844
[6]   Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions A Randomized Controlled Trial [J].
Hyun, Seung-Jae ;
Kim, Ki-Jeong ;
Jahng, Tae-Ahn ;
Kim, Hyun-Jib .
SPINE, 2017, 42 (06) :353-358
[7]   Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement [J].
Kantelhardt, Sven Rainer ;
Martinez, Ramon ;
Baerwinkel, Stefan ;
Burger, Ralf ;
Giese, Alf ;
Rohde, Veit .
EUROPEAN SPINE JOURNAL, 2011, 20 (06) :860-868
[8]   Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis [J].
Keric N. ;
Eum D.J. ;
Afghanyar F. ;
Rachwal-Czyzewicz I. ;
Renovanz M. ;
Conrad J. ;
Wesp D.M.A. ;
Kantelhardt S.R. ;
Giese A. .
Journal of Robotic Surgery, 2017, 11 (1) :17-25
[9]  
Kim HJ, 2016, INT J MED ROBOT, V13, P3
[10]   Monitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Test [J].
Kim, Ho-Joong ;
Lee, Seung Hoo ;
Chang, Bong-Soon ;
Lee, Choon-Ki ;
Lim, Teck Onn ;
Hoo, Ling Ping ;
Yi, Je-Min ;
Yeom, Jin S. .
SPINE, 2015, 40 (02) :87-94