Comparison of electrochemical, electrophoretic and spectrophotometric methods for creatinine determination in biological fluids

被引:50
作者
Walsh, DA
Dempsey, E [1 ]
机构
[1] Inst Technol, Dept Appl Sci, Dublin 24, Ireland
[2] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
关键词
creatinine; biosensor; flow cell; micellar electrokinetic chromatography; Jaffe reaction;
D O I
10.1016/S0003-2670(02)00110-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitation of creatinine in biological fluids was achieved using both a biosensor based electrochemical flow cell and a micellar electrokinetic chromatography (MEKC) separation method. The results obtained from each method were compared with the widely recognised clinical method based on the Jaffe reaction. This is a standard spectrophotometric assay based on the Jaffe reaction of creatinine with alkaline picrate. The biosensor for creatinine was constructed by co-immobilising the enzymes creatininase, creatinase and sarcosine oxidase (SO) using a bovine serum albumin (BSA)-glutaraldehyde (GA) procedure at a platinum electrode. Detection of the hydrogen peroxide product of the third enzyme-catalysed reaction (SO) allowed the measurement of creatinine at +0.7 V versus Ag/AgCl. The biosensor was incorporated into a flow cell arrangement which allowed rapid determination of creatinine concentrations in urine samples with a limit of detection of 4.5 muM, a response time of 1 min, a linear range of 0-500 muM and a precision of 1.14% (n = 10). The results for five urine samples were compared with the Jaffe reaction method and based on this number of samples results from the spectrophotometric method were 36.7% higher than those determined using the flow cell method. A MEKC method for creatinine determination in serum samples was also developed and employed for serum analysis, with only a simple filtration step as sample preparation. The method showed a limit of detection of 11.5 muM, a linear range of 0-4.4 mM and a peak area precision of 2.7% (n = 10). The method was applied to creatinine determination in serum samples (n = 13) from patients undergoing renal dialysis and the results compared to the Jaffe reaction procedure. The Jaffe method generated values on average 26.7% greater than the corresponding MEKC results. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 50 条
[41]   Comparison of chemical, electrophoretic and in vitro digestion methods for predicting fish meal nutritive quality [J].
Bassompierre, M. ;
Larsen, K. L. ;
Zimmermann, W. ;
McLean, E. ;
Borresen, T. ;
Sandfeld, P. .
AQUACULTURE NUTRITION, 1998, 4 (04) :233-239
[42]   MULTICOMMUTATION IN FLOW-ANALYSIS .3. SPECTROPHOTOMETRIC KINETIC DETERMINATION OF CREATININE IN URINE EXPLOITING A NOVEL ZONE SAMPLING APPROACH [J].
ARAUJO, AN ;
LIMA, JLFC ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :447-452
[43]   Spectrophotometric simultaneous determination of ceratine, creatinine, and uric acid in real samples by orthogonal signal correction–partial least squares regression [J].
Habibollah Khajehsharifi ;
Masoumeh Sadeghi ;
Eslam Pourbasheer .
Monatshefte für Chemie - Chemical Monthly, 2009, 140 :685-691
[44]   Capillary electrophoretic methods for the screening and determination of pharmacologic adulterants in herbal-based pharmaceutical formulations [J].
Moreira, Ana Paula L. ;
Martini, Mariele ;
de Carvalho, Leandro M. .
ELECTROPHORESIS, 2014, 35 (21-22) :3212-3230
[45]   Comparison of creatinine-based methods for estimating glomerular filtration rate in patients with heart failure [J].
Jonsson, Anna ;
Viklund, Ida ;
Jonsson, Andreas ;
Valham, Fredrik ;
Bergdahl, Ellinor ;
Lindmark, Krister ;
Norberg, Helena .
ESC HEART FAILURE, 2020, 7 (03) :1150-1160
[46]   Different methods of on-line preconcentration in the electrophoretic determination of amines, amino acids, and steroid hormones [J].
Kartsova, L. A. ;
Sidorova, A. A. ;
Bessonova, E. A. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (07) :642-648
[47]   Molecularly imprinted polymer dual electrochemical sensor for the one-step determination of albuminuria to creatinine ratio (ACR) [J].
Wardani, Nur Indah ;
Kanatharana, Proespichaya ;
Thavarungkul, Panote ;
Limbut, Warakorn .
TALANTA, 2023, 265
[48]   A Multi-electrochemical Competitive Immunosensor for Sensitive Cocaine Determination in Biological Samples [J].
Vidal, Juan C. ;
Bertolin, Juan R. ;
Bonel, Laura ;
Asturias, Laura ;
Julia Arcos-Martinez, M. ;
Castillo, Juan R. .
ELECTROANALYSIS, 2016, 28 (04) :685-694
[49]   Spectrophotometric simultaneous determination of ceratine, creatinine, and uric acid in real samples by orthogonal signal correction-partial least squares regression [J].
Khajehsharifi, Habibollah ;
Sadeghi, Masoumeh ;
Pourbasheer, Eslam .
MONATSHEFTE FUR CHEMIE, 2009, 140 (06) :685-691
[50]   A sensitive electrochemical sensor for rapid and selective determination of venlafaxine in biological fluids using carbon paste electrode modified with molecularly imprinted polymer-coated magnetite nanoparticles [J].
Madrakian, Tayyebeh ;
Haryani, Reza ;
Ahmadi, Mazaher ;
Afkhami, Abbas .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2016, 13 (02) :243-251