Comparison of electrochemical, electrophoretic and spectrophotometric methods for creatinine determination in biological fluids

被引:50
作者
Walsh, DA
Dempsey, E [1 ]
机构
[1] Inst Technol, Dept Appl Sci, Dublin 24, Ireland
[2] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
关键词
creatinine; biosensor; flow cell; micellar electrokinetic chromatography; Jaffe reaction;
D O I
10.1016/S0003-2670(02)00110-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitation of creatinine in biological fluids was achieved using both a biosensor based electrochemical flow cell and a micellar electrokinetic chromatography (MEKC) separation method. The results obtained from each method were compared with the widely recognised clinical method based on the Jaffe reaction. This is a standard spectrophotometric assay based on the Jaffe reaction of creatinine with alkaline picrate. The biosensor for creatinine was constructed by co-immobilising the enzymes creatininase, creatinase and sarcosine oxidase (SO) using a bovine serum albumin (BSA)-glutaraldehyde (GA) procedure at a platinum electrode. Detection of the hydrogen peroxide product of the third enzyme-catalysed reaction (SO) allowed the measurement of creatinine at +0.7 V versus Ag/AgCl. The biosensor was incorporated into a flow cell arrangement which allowed rapid determination of creatinine concentrations in urine samples with a limit of detection of 4.5 muM, a response time of 1 min, a linear range of 0-500 muM and a precision of 1.14% (n = 10). The results for five urine samples were compared with the Jaffe reaction method and based on this number of samples results from the spectrophotometric method were 36.7% higher than those determined using the flow cell method. A MEKC method for creatinine determination in serum samples was also developed and employed for serum analysis, with only a simple filtration step as sample preparation. The method showed a limit of detection of 11.5 muM, a linear range of 0-4.4 mM and a peak area precision of 2.7% (n = 10). The method was applied to creatinine determination in serum samples (n = 13) from patients undergoing renal dialysis and the results compared to the Jaffe reaction procedure. The Jaffe method generated values on average 26.7% greater than the corresponding MEKC results. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 50 条
[31]   Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids [J].
Pormsila, Worapan ;
Krahenbuehl, Stephan ;
Hauser, Peter C. .
ANALYTICA CHIMICA ACTA, 2009, 636 (02) :224-228
[32]   Sensitive determination of ciprofloxacin and norfloxacin in biological fluids using an enzymatic rotating biosensor [J].
Torriero, Angel A. J. ;
Salinas, Eloy ;
Raba, Julio ;
Silber, Juana J. .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :109-115
[33]   EVALUATION AND ELIMINATION OF THE INTERFERENCE EFFECTS OF 3 CEPHALOSPORINS ON THE KINETIC-SPECTROPHOTOMETRIC DETERMINATION OF CREATININE IN SERUM USING THE JAFFE REACTION [J].
SEVILLANOCABEZA, A ;
HERRAEZHERNANDEZ, R ;
CAMPINSFALCO, P .
ANALYTICAL LETTERS, 1991, 24 (10) :1741-1766
[34]   Very fast electrophoretic determination of creatinine and uric acid in human urine using a combination of two capillaries with different internal diameters [J].
Pavlicek, Vaclav ;
Tuma, Petr ;
Matejckova, Jana ;
Samcova, Eva .
ELECTROPHORESIS, 2014, 35 (07) :956-961
[35]   Creatinine concentration in plasma from dog, rat, and mouse: a comparison of 3 different methods [J].
Palm, M ;
Lundblad, A .
VETERINARY CLINICAL PATHOLOGY, 2005, 34 (03) :232-236
[36]   Very Fast Electrophoretic Determination of Creatinine and Uric Acid in Human Urine using a Combination of Two Capillaries with Different Inner Diameters [J].
Pavlicek, Vaclav ;
Tuma, Petr .
XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, :144-148
[37]   Electrochemical and Other Methods for Detection and Determination of Dissolved Nitrite: A Review [J].
Zhao Yilong ;
Zhao Dean ;
Li Daoliang .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02) :1144-1168
[38]   Electrochemical methods for the determination of urea: Current trends and future perspective [J].
Quadrini, Lorenzo ;
Laschi, Serena ;
Ciccone, Claudio ;
Catelani, Filippo ;
Palchetti, Ilaria .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 168
[39]   Electrochemical determination of superoxide and nitric oxide generated from biological samples [J].
Mesaros, S ;
Vankova, Z ;
Mesarosova, A ;
Tomcik, P ;
Grunfeld, S .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 46 (01) :33-37
[40]   In Situ Nanocoating on Porous Pyrolyzed Paper Enables Antibiofouling and Sensitive Electrochemical Analyses in Biological Fluids [J].
Nicoliche, Caroline Y. N. ;
Pascon, Aline M. ;
Bezerra, Italo R. S. ;
de Castro, Ana C. H. ;
Martos, Gabriel R. ;
Bettini, Jefferson ;
Alves, Wendel A. ;
Santhiago, Murilo ;
Lima, Renato S. .
ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (02) :2522-2533