Use of quantitative T2 mapping for the assessment of renal cell carcinomas: first results

被引:34
作者
Adams, Lisa C. [1 ]
Bressem, Keno K. [2 ]
Jurmeister, Phillipp [3 ]
Fahlenkamp, Ute L. [1 ]
Ralla, Bernhard [4 ]
Engel, Guenther [1 ]
Hamm, Bernd [1 ]
Busch, Jonas [1 ]
Makowski, Marcus R. [1 ]
机构
[1] Charite, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Charite, Dept Radiol, Hindenburgdamm 30, D-12203 Berlin, Germany
[3] Charite, Dept Pathol, Charitepl 1, D-10117 Berlin, Germany
[4] Charite, Dept Urol, Charitepl 1, D-10117 Berlin, Germany
关键词
MRI mapping techniques; Quantitative MRI; T2; mapping; Clear cell renal cell carcinoma; Tumor grading; APPARENT DIFFUSION-COEFFICIENTS; HIGH-SPATIAL-RESOLUTION; MAGNETIC-RESONANCE; HUMAN MYOCARDIUM; PROGRESSION; PATTERNS; CONTRAST; MASSES;
D O I
10.1186/s40644-019-0222-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundCorrect staging and grading of patients with clear cell renal cell carcinoma (cRCC) is of clinical relevance for the prediction of operability and for individualized patient management. As partial or radial resection with postoperative tumor grading currently remain the methods of choice for the classification of cRCC, non-invasive preoperative alternatives to differentiate lower grade from higher grade cRCC would be beneficial.MethodsThis institutional-review-board approved cross-sectional study included twenty-seven patients (8 women, mean ageSD, 61.314.2) with histopathologically confirmed cRCC, graded according to the International Society of Urological Pathology (ISUP). A native, balanced steady-state free precession T2 mapping sequence (TrueFISP) was performed at 1.5T. Quantitative T2 values were measured with circular 2D ROIs in the solid tumor portion and also in the normal renal parenchyma (cortex and medulla). To estimate the optimal cut-off T2 value for identifying lower grade cRCC, a Receiver Operating Characteristic Curve (ROC) analysis was performed and sensitivity and specificity were calculated. Students' t-tests were used to evaluate the differences in mean values for continuous variables, while intergroup differences were tested for significance with two-tailed Mann-Whitney-U tests.ResultsThere were significant differences between the T2 values for lower grade (ISUP 1-2) and higher grade (ISUP 3-4) cRCC (p<0.001), with higher T2 values for lower grade cRCC compared to higher grade cRCC. The sensitivity and specificity for the differentiation of lower grade from higher grade tumors were 83.3% (95% CI: 0.59-0.96) and 88.9% (95% CI: 0.52-1.00), respectively, using a threshold value of 110ms. Intraobserver/interobserver agreement for T2 measurements was excellent/substantial.ConclusionsNative T2 mapping based on a balanced steady-state free precession MR sequence might support an image-based distinction between lower and higher grade cRCC in a two-tier-system and could be a helpful addition to multiparametric imaging.
引用
收藏
页数:11
相关论文
共 44 条
[1]   Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis -: Comparison of different approaches [J].
Abdel-Aty, H ;
Boyé, P ;
Zagrosek, A ;
Wassmuth, R ;
Kumar, A ;
Messroghli, D ;
Bock, P ;
Dietz, R ;
Friedrich, MG ;
Schulz-Menger, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) :1815-1822
[2]  
Abdel-Aty Hassan, 2007, Recent Pat Cardiovasc Drug Discov, V2, P63, DOI 10.2174/157489007779606167
[3]  
Al Nazer M, 2000, DIAGN CYTOPATHOL, V22, P223, DOI 10.1002/(SICI)1097-0339(200004)22:4<223::AID-DC4>3.0.CO
[4]  
2-B
[5]   Cardiac T2-mapping using a fast gradient echo spin echo sequence - first in vitro and in vivo experience [J].
Baessler, Bettina ;
Schaarschmidt, Frank ;
Stehning, Christian ;
Schnackenburg, Bernhard ;
Maintz, David ;
Bunck, Alexander C. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[6]   In-vivo quantitative T2 mapping of carotid arteries in atherosclerotic patients: segmentation and T2 measurement of plaque components [J].
Biasiolli, Luca ;
Lindsay, Alistair C. ;
Chai, Joshua T. ;
Choudhury, Robin P. ;
Robson, Matthew D. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[7]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[8]   Cardiovascular magnetic resonance in the diagnosis of acute heart transplant rejection: a review [J].
Butler, Craig R. ;
Thompson, Richard ;
Haykowsky, Mark ;
Toma, Mustafa ;
Paterson, Ian .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
[9]  
Campbell Naomi, 2014, Top Magn Reson Imaging, V23, P95, DOI 10.1097/RMR.0000000000000019
[10]   Quantitative Multiparametric MRI of Ovarian Cancer [J].
Carter, Jori S. ;
Koopmeiners, Joseph S. ;
Kuehn-Hajder, Jessica E. ;
Metzger, Gregory J. ;
Lakkadi, Navneeth ;
Downs, Levi S., Jr. ;
Bolan, Patrick J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) :1501-1509