Mapping of Scapular Fractures with Three-Dimensional Computed Tomography

被引:149
|
作者
Armitage, Bryan M. [1 ]
Wijdicks, Coen A.
Tarkin, Ivan S.
Schroder, Lisa K.
Marek, Daniel J.
Zlowodzki, Michael
Cole, Peter A.
机构
[1] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55454 USA
来源
关键词
INTERNAL-FIXATION; OPEN REDUCTION; FLOATING SHOULDER; GLENOID FOSSA; CLASSIFICATION; TRAUMA; NECK;
D O I
10.2106/JBJS.H.00881
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Fractures of the scapula involve a unique and challenging set of considerations, which must be understood to provide optimal treatment. The primary goal of this study was to create a frequency map of a series of surgically treated scapular fractures that specifically involved the scapular body and/or neck. Methods: A prospective database was used in the collection of consecutive radiographic imaging studies of patients undergoing operative treatment of scapular fractures. Scanned three-dimensional computed tomography images were superimposed and oriented to fit a model scapular template. Size dimensions were normalized by aligning specific scapular landmarks. Fracture lines were identified and traced over the combined three-dimensional computed tomography model to create a scapular fracture map. Results: Of ninety fractures that met the criteria for inclusion, 68% involved the inferior aspect of the glenoid neck and 71% involved the superior vertebral border. Seventeen percent of the patterns included articular extension, and 22% of the fractures entered the spinoglenoid notch. Of fractures involving the inferior aspect of the glenoid neck at the lateral scapular border, 84% traversed medially to exit just inferior to the medial extent of the scapular spine, and 59% of these inferior neck fractures also had propagation to the inferior third of the vertebral border. Among the fractures involving the spinoglenoid notch, the most common pattern was demonstrated by coexisting fracture lines; 60% of the fractures of the spinoglenoid notch exited just inferior to the glenoid, 65% extended to the superior-medial vertebral border, and 45% extended to the inferior-medial vertebral border. In contrast, articular fractures did not follow predictable patterns; they demonstrated the greatest variability in trajectory, which was almost random, and there was a wide distribution of exit points along the vertebral border. Conclusions: Surgically treated scapular fractures display very common patterns. The most common pattern is the lateral border fracture immediately inferior to the glenoid, which extends to the superior vertebral border in more than two-thirds of cases. A smaller proportion of scapular fractures enter the spinoglenoid notch or the articular surface. There is great variation in the patterns of fractures involving the articular surface.
引用
收藏
页码:2222 / 2228
页数:7
相关论文
共 50 条
  • [31] A novel three-dimensional classification system for intertrochanteric fractures based on computed tomography findings
    Wada, Keizo
    Mikami, Hiroshi
    Amari, Rui
    Toki, Shunichi
    Takai, Michihiro
    Sairyo, Koichi
    JOURNAL OF MEDICAL INVESTIGATION, 2019, 66 (3-4): : 362 - 366
  • [32] Value of three-dimensional computed tomography reconstruction in the treatment of posterior tibial plateau fractures
    Van den Berg, J.
    Struelens, B.
    Nijs, S.
    Hoekstra, H.
    KNEE, 2020, 27 (01): : 3 - 8
  • [33] The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures
    Harness, Neil G.
    Ring, David
    Zurakowski, David
    Harris, Gordon J.
    Jupiter, Jesse B.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (06): : 1315 - 1323
  • [34] Three-Dimensional Computed Tomography of the Carpal Ligaments
    Nanno, Mitsuhiko
    Viegas, Steven F.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2009, 13 (01) : 3 - 17
  • [35] Three-dimensional computed tomography of the pulmonary veins
    Tada, H
    Oral, H
    Knight, BP
    Morady, F
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 521 - 521
  • [36] Application Research of Three-Dimensional Printing Technology and Three-Dimensional Computed Tomography in Segmentectomy
    Tongxin, Li
    Jing, Xu
    Runyuan, Wang
    Wei, Wu
    Yu, Zhou
    Dong, Wang
    Wang, He
    Yi, Wu
    Ping, He
    Yong, Fu
    FRONTIERS IN SURGERY, 2022, 9
  • [37] Two-Dimensional Versus Three-Dimensional Computed Tomography
    Wiwanitkit, Viroj
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (03): : 513 - 513
  • [38] A three-dimensional computed tomography study of the palmar ulnar corner fragment in distal radial fractures
    Hubbard, James
    Berry, David
    Chauhan, Aakash
    Casstevens, Chris
    Shin, Alexander Y.
    Abrams, Reid A.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (03) : 300 - 309
  • [39] Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures
    Hu, Yan-Ling
    Ye, Fa-Gang
    Ji, Ai-Yu
    Qiao, Guang-Xi
    Liu, Hai-Fei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (12): : 1282 - 1285
  • [40] Spiral computed tomography with two- and three-dimensional reconstruction in the management of tibial plateau fractures
    Liow, RYL
    Birdsall, PD
    Mucci, B
    Greiss, ME
    ORTHOPEDICS, 1999, 22 (10) : 929 - 932