Amine-Functionalized MoO3@RGO Nanohybrid-Based Biosensor for Breast Cancer Detection

被引:66
作者
Augustine, Shine [1 ]
Kumar, Pragati [2 ]
Malhotra, Bansi D. [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Nanobioelect Lab, Delhi 110042, India
[2] Delhi Technol Univ, Dept Elect Engn, Delhi 110042, India
关键词
molybdenum oxide; RGO; nanohybrid; label-free; HER-2; breast cancer; SCREEN-PRINTED ELECTRODE; LABEL-FREE DETECTION; ELECTROCHEMICAL IMMUNOSENSOR; ULTRASENSITIVE DETECTION; MOLYBDENUM TRIOXIDE; OXIDE; GRAPHENE; PLATFORM; BIOMARKER; HER2;
D O I
10.1021/acsabm.9b00659
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We report results of studies relating to development of an ultrasensitive, rapid, and label-free biosensor based on molybdenum trioxide (MoO3) anchored onto the reduced graphene oxide (RGO) for breast cancer detection. The human epidermal growth factor receptor-2 (HER-2) secreted in the serum of breast cancer patients was used as an analyte for the detection. The in situ growth of 1D MoO3 onto reduced graphene oxide (RGO), a 2D carbon substrate, was carried out via one-pot low-temperature hydrothermal synthesis. Subsequently, the surface conjugation of the monoclonal antibodies (anti-HER-2) onto the APTES/MoO3@RGO/ITO electrode was conducted via EDC-NHS covalent chemistry. The structural and morphological properties of the MoO3@RGO nanohybrid were investigated using electron microscopy, X-ray diffraction, scanning electron microscopy, transmission electron microscopy and X-ray photoelectron spectroscopic techniques. The surface area of the MoO3@RGO nanohybrid determined via Brauner-Emmett-Teller analysis was found to be 14 times greater than that of the pristine MoO3. The binding kinetics and the electrochemical activity of the developed platform were determined by cyclic voltammetry, differential pulse voltammetry, and impedance spectroscopic techniques. This nanohybrid based immunosensor exhibited improved sensitivity (13 uA mLng(-1)cm(-2)) in a broad concentration range (0.001-500 ng mL(-1)) with a correlation coefficient of 0.98. The limit of detection of this MoO3@RGO nanohybrid based immunosensor was found to be 0.001 ng mL(-1). The results obtained via the developed immunosensor for the quantification of serum HER-2 were validated using ELISA.
引用
收藏
页码:5366 / 5378
页数:13
相关论文
共 68 条
  • [51] A label-free electrochemical affisensor for cancer marker detection: The case of HER2
    Ravalli, Andrea
    da Rocha, Carolina Gomes
    Yamanaka, Hideko
    Marrazza, Giovanna
    [J]. BIOELECTROCHEMISTRY, 2015, 106 : 268 - 275
  • [52] Reverberi Roberto, 2007, Blood Transfus, V5, P227, DOI 10.2450/2007.0047-07
  • [53] Ultrasensitive direct impedimetric immunosensor for detection of serum HER2
    Sharma, Shikha
    Zapatero-Rodriguez, Julia
    Saxena, Rahul
    O'Kennedy, Richard
    Srivastava, Sudha
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 106 : 78 - 85
  • [54] Label-free Detection of Influenza Viruses using a Reduced Graphene Oxide-based Electrochemical Immunosensor Integrated with a Microfluidic Platform
    Singh, Renu
    Hong, Seongkyeol
    Jang, Jaesung
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [55] Multi-walled carbon nanotubes/sol-gel-derived silica/chitosan nanobiocomposite for total cholesterol sensor
    Solanki, Pratima R.
    Kaushik, Ajeet
    Ansari, Anees A.
    Tiwari, A.
    Malhotra, B. D.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02): : 727 - 735
  • [56] Electrophoretically deposited reduced graphene oxide platform for food toxin detection
    Srivastava, Saurabh
    Kumar, Vinod
    Ali, Md Azahar
    Solanki, Pratima R.
    Srivastava, Anchal
    Sumana, Gajjala
    Saxena, Preeti Suman
    Joshi, Amish G.
    Malhotra, B. D.
    [J]. NANOSCALE, 2013, 5 (07) : 3043 - 3051
  • [57] Reduced graphene oxide-chitosan-aptamer interface as new platform for ultrasensitive detection of human epidermal growth factor receptor 2
    Tabasi, Arezoo
    Noorbakhsh, Abdollah
    Sharifi, Ensiyeh
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 95 : 117 - 123
  • [58] Development of screen-printed electrode based immunosensor for the detection of HER2 antigen in human serum samples
    Tallapragada, Sagarika Deepthy
    Layek, Keya
    Mukherjee, Runu
    Mistry, Kalyan Kumar
    Ghosh, Monidipa
    [J]. BIOELECTROCHEMISTRY, 2017, 118 : 25 - 30
  • [59] Two-dimensional transition metal dichalcogenide nanosheet-based composites
    Tan, Chaoliang
    Zhang, Hua
    [J]. CHEMICAL SOCIETY REVIEWS, 2015, 44 (09) : 2713 - 2731
  • [60] Anti-IL8/AuNPs-rGO/ITO as an Immunosensing Platform for Noninvasive Electrochemical Detection of Oral Cancer
    Verma, Shilpi
    Singh, Anu
    Shukla, Ajay
    Kaswan, Jyoti
    Arora, Kavita
    Ramirez-Vick, Jaime
    Singh, Priti
    Singh, Surinder P.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (33) : 27462 - 27474