Amine-Functionalized MoO3@RGO Nanohybrid-Based Biosensor for Breast Cancer Detection

被引:66
作者
Augustine, Shine [1 ]
Kumar, Pragati [2 ]
Malhotra, Bansi D. [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Nanobioelect Lab, Delhi 110042, India
[2] Delhi Technol Univ, Dept Elect Engn, Delhi 110042, India
关键词
molybdenum oxide; RGO; nanohybrid; label-free; HER-2; breast cancer; SCREEN-PRINTED ELECTRODE; LABEL-FREE DETECTION; ELECTROCHEMICAL IMMUNOSENSOR; ULTRASENSITIVE DETECTION; MOLYBDENUM TRIOXIDE; OXIDE; GRAPHENE; PLATFORM; BIOMARKER; HER2;
D O I
10.1021/acsabm.9b00659
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We report results of studies relating to development of an ultrasensitive, rapid, and label-free biosensor based on molybdenum trioxide (MoO3) anchored onto the reduced graphene oxide (RGO) for breast cancer detection. The human epidermal growth factor receptor-2 (HER-2) secreted in the serum of breast cancer patients was used as an analyte for the detection. The in situ growth of 1D MoO3 onto reduced graphene oxide (RGO), a 2D carbon substrate, was carried out via one-pot low-temperature hydrothermal synthesis. Subsequently, the surface conjugation of the monoclonal antibodies (anti-HER-2) onto the APTES/MoO3@RGO/ITO electrode was conducted via EDC-NHS covalent chemistry. The structural and morphological properties of the MoO3@RGO nanohybrid were investigated using electron microscopy, X-ray diffraction, scanning electron microscopy, transmission electron microscopy and X-ray photoelectron spectroscopic techniques. The surface area of the MoO3@RGO nanohybrid determined via Brauner-Emmett-Teller analysis was found to be 14 times greater than that of the pristine MoO3. The binding kinetics and the electrochemical activity of the developed platform were determined by cyclic voltammetry, differential pulse voltammetry, and impedance spectroscopic techniques. This nanohybrid based immunosensor exhibited improved sensitivity (13 uA mLng(-1)cm(-2)) in a broad concentration range (0.001-500 ng mL(-1)) with a correlation coefficient of 0.98. The limit of detection of this MoO3@RGO nanohybrid based immunosensor was found to be 0.001 ng mL(-1). The results obtained via the developed immunosensor for the quantification of serum HER-2 were validated using ELISA.
引用
收藏
页码:5366 / 5378
页数:13
相关论文
共 68 条
  • [31] Biofunctionalized two-dimensional Ti3C2 MXenes for ultrasensitive detection of cancer biomarker
    Kumar, Saurabh
    Lei, Yongjiu
    Alshareef, Niman H.
    Quevedo-Lopez, M. A.
    Salama, Khaled N.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 121 : 243 - 249
  • [32] Nanostructured zirconia decorated reduced graphene oxide based efficient biosensing platform for non-invasive oral cancer detection
    Kumar, Suveen
    Sharma, Jai Gopal
    Maji, Sagar
    Malhotra, Bansi Dhar
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 78 : 497 - 504
  • [33] Surface characterization of immunosensor conjugated with gold nanoparticles based on cyclic voltammetry and X-ray photoelectron spectroscopy
    Lai, Lee-Jene
    Yang, Yaw-Wen
    Lin, Yao-Kwang
    Huang, Li-Ling
    Hsieh, Yi-Heui
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 68 (02) : 130 - 135
  • [34] Current Therapies for Human Epidermal Growth Factor Receptor 2-Positive Metastatic Breast Cancer Patients
    Larionov, Alexey A.
    [J]. FRONTIERS IN ONCOLOGY, 2018, 8
  • [35] Nanohybridization of molybdenum oxide with tungsten molybdenum oxide nanowires for solution-processed fully reversible switching of energy storing smart windows
    Li, Haizeng
    McRae, Liam
    Firby, Curtis J.
    Al-Hussein, Mohamed
    Elezzabi, Abdulhakem Y.
    [J]. NANO ENERGY, 2018, 47 : 130 - 139
  • [36] Nitidine chloride-assisted bio-functionalization of reduced graphene oxide by bovine serum albumin for impedimetric immunosensing
    Li, Yu
    Zhang, Zhao
    Zhang, Yuting
    Deng, Dongmei
    Luo, Liqiang
    Han, Baosan
    Fan, Chunhai
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 79 : 536 - 542
  • [37] Kinetics of (3-Aminopropyl)triethoxylsilane (APTES) Silanization of Superparamagnetic Iron Oxide Nanoparticles
    Liu, Yue
    Li, Yueming
    Li, Xue-Mei
    He, Tao
    [J]. LANGMUIR, 2013, 29 (49) : 15275 - 15282
  • [38] Multiwall carbon nanotube (MWCNT) based electrochemical biosensors for mediatorless detection of putrescine
    Luong, JHT
    Hrapovic, S
    Wang, DS
    [J]. ELECTROANALYSIS, 2005, 17 (01) : 47 - 53
  • [39] Electrochemical immunosensor for the analysis of the breast cancer biomarker HER2 ECD
    Marques, Raquel C. B.
    Viswanathan, Subramanian
    Nouws, Henri P. A.
    Delerue-Matos, Cristina
    Begona Gonzalez-Garcia, M.
    [J]. TALANTA, 2014, 129 : 594 - 599
  • [40] Current technologies for HER2 testing in breast cancer
    Moelans, C. B.
    de Weger, R. A.
    Van der Wall, E.
    van Diest, P. J.
    [J]. CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 80 (03) : 380 - 392