Amine-Functionalized MoO3@RGO Nanohybrid-Based Biosensor for Breast Cancer Detection

被引:66
作者
Augustine, Shine [1 ]
Kumar, Pragati [2 ]
Malhotra, Bansi D. [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Nanobioelect Lab, Delhi 110042, India
[2] Delhi Technol Univ, Dept Elect Engn, Delhi 110042, India
关键词
molybdenum oxide; RGO; nanohybrid; label-free; HER-2; breast cancer; SCREEN-PRINTED ELECTRODE; LABEL-FREE DETECTION; ELECTROCHEMICAL IMMUNOSENSOR; ULTRASENSITIVE DETECTION; MOLYBDENUM TRIOXIDE; OXIDE; GRAPHENE; PLATFORM; BIOMARKER; HER2;
D O I
10.1021/acsabm.9b00659
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We report results of studies relating to development of an ultrasensitive, rapid, and label-free biosensor based on molybdenum trioxide (MoO3) anchored onto the reduced graphene oxide (RGO) for breast cancer detection. The human epidermal growth factor receptor-2 (HER-2) secreted in the serum of breast cancer patients was used as an analyte for the detection. The in situ growth of 1D MoO3 onto reduced graphene oxide (RGO), a 2D carbon substrate, was carried out via one-pot low-temperature hydrothermal synthesis. Subsequently, the surface conjugation of the monoclonal antibodies (anti-HER-2) onto the APTES/MoO3@RGO/ITO electrode was conducted via EDC-NHS covalent chemistry. The structural and morphological properties of the MoO3@RGO nanohybrid were investigated using electron microscopy, X-ray diffraction, scanning electron microscopy, transmission electron microscopy and X-ray photoelectron spectroscopic techniques. The surface area of the MoO3@RGO nanohybrid determined via Brauner-Emmett-Teller analysis was found to be 14 times greater than that of the pristine MoO3. The binding kinetics and the electrochemical activity of the developed platform were determined by cyclic voltammetry, differential pulse voltammetry, and impedance spectroscopic techniques. This nanohybrid based immunosensor exhibited improved sensitivity (13 uA mLng(-1)cm(-2)) in a broad concentration range (0.001-500 ng mL(-1)) with a correlation coefficient of 0.98. The limit of detection of this MoO3@RGO nanohybrid based immunosensor was found to be 0.001 ng mL(-1). The results obtained via the developed immunosensor for the quantification of serum HER-2 were validated using ELISA.
引用
收藏
页码:5366 / 5378
页数:13
相关论文
共 68 条
  • [1] Al-Khafaji Q., 2011, SENSORS MICROSYSTEMS, P157
  • [2] A biofunctionalized quantum dot-nickel oxide nanorod based smart platform for lipid detection
    Ali, Md. Azahar
    Srivastava, Saurabh
    Agrawal, Ved V.
    Willander, Magnus
    John, Renu
    Malhotra, Bansi D.
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (15) : 2706 - 2714
  • [3] Protein Functionalized Carbon Nanotubes-based Smart Lab-on-a-Chip
    Ali, Md. Azahar
    Solanki, Pratima R.
    Srivastava, Saurabh
    Singh, Samer
    Agrawal, Ved V.
    John, Renu
    Malhotra, Bansi D.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (10) : 5837 - 5846
  • [4] A surface functionalized nanoporous titania. integrated microfluidic biochip
    Ali, Md. Azahar
    Srivastava, Saurabh
    Mondal, Kunal
    Chavhan, Pandurang M.
    Agrawal, Ved V.
    John, Renu
    Sharma, Ashutosh
    Malhotra, Bansi D.
    [J]. NANOSCALE, 2014, 6 (22) : 13958 - 13969
  • [5] ELECTROANALYTICAL CHARACTERIZATION OF CARBON BLACK NANOMATERIAL PASTE ELECTRODE: DEVELOPMENT OF HIGHLY SENSITIVE TYROSINASE BIOSENSOR FOR CATECHOL DETECTION
    Arduini, Fabiana
    Di Giorgio, Floriana
    Amine, Aziz
    Cataldo, Franco
    Moscone, Danila
    Palleschi, Giuseppe
    [J]. ANALYTICAL LETTERS, 2010, 43 (10-11) : 1688 - 1702
  • [6] A novel antibody-antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode
    Arkan, Elham
    Saber, Reza
    Karimi, Ziba
    Shamsipur, Mojtaba
    [J]. ANALYTICA CHIMICA ACTA, 2015, 874 : 66 - 74
  • [7] An emerging nanostructured molybdenum trioxide based biocompatible sensor platform for breast cancer biomarker detection
    Augustine, Shine
    Joshi, Amish G.
    Yadav, Birendra Kumar
    Mehta, Anurag
    Kumar, Preget
    Renugopalakrishanan, Venkatesan
    Malhotra, Bansi D.
    [J]. MRS COMMUNICATIONS, 2018, 8 (03) : 668 - 679
  • [8] A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer
    Aydin, Elif Burcu
    Sezginturk, Mustafa Kemal
    [J]. TALANTA, 2017, 172 : 162 - 170
  • [9] Stepwise Reduction of Graphene Oxide (GO) and Its Effects on Chemical and Colloidal Properties
    Azizighannad, Samar
    Mitra, Somenath
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [10] Synthesis of MoO3/reduced graphene oxide hybrids and mechanism of enhancing H2S sensing performances
    Bai, Shouli
    Chen, Chao
    Luo, Ruixian
    Chen, Aifan
    Li, Dianqing
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 113 - 120