[6] Univ Lisbon, Inst Super Tecn, Lab Protecao & Seguranca Radiol, Estrada Nacl 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[7] UL, IST, C2TN, EN 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[8] Guys & St Thomas NHS Fdn Trust, London, England
关键词
BREAST SCREENING-PROGRAM; DIAGNOSTIC REFERENCE LEVELS; FIELD DIGITAL MAMMOGRAPHY; DOSIMETRY; UK; PROTOCOLS; DENSITY; PHANTOM; 6-YEAR;
D O I
10.1093/rpd/ncx300
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was estimated using exposure settings collected from mammography exams in clinical context. Data were collected from 25 computed-radiography systems (CR) and 13 integrated digital (DR). For both measurements (phantom and clinical exposures), the average MGD for CR was higher compared to the DR. For CR the mean MGD was 1.85 mGy (CC projection) and 2.10 mGy (MLO projection). For DR systems the corresponding values were 1.54 mGy (CC) and 1.68 mGy (MLO). The average MGD obtained using both methods and for both technologies is within the acceptable reference range proposed by European guidelines (<2.5 mGy). Dose Reference Levels implementation should be the next step to optimise mammography practice in Portugal.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 33 条
[31]   Radiation doses received in the UK Breast Screening Programme in 2001 and 2002 [J].
Young, KC ;
Burch, A ;
Oduko, JM .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (927) :207-218
[32]   Radiation doses received in the UK Breast Screening Programme in 1997 and 1998 [J].
Young, KC ;
Burch, A .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (867) :278-287
[33]   Radiation doses received in the United Kingdom breast screening programme in 2010 to 2012 [J].
Young, Kenneth C. ;
Oduko, Jennifer M. .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)