PORTUGUESE STUDY OF MEAN GLANDULAR DOSE IN MAMMOGRAPHY AND COMPARISON WITH EUROPEAN REFERENCES

被引:9
作者
dos Reis, Claudia Sa [1 ,2 ,3 ]
Fartaria, Mario Joao [3 ,4 ,5 ,6 ]
Garcia Alves, Joao H. [6 ,7 ]
Pascoal, Ana [3 ,8 ]
机构
[1] Curtin Univ, Dept Med Radiat Sci, Perth, WA, Australia
[2] Inst Politecn Lisboa ESTeSL IPL, Escola Super Tecnol Saude Lisboa, Lisbon, Portugal
[3] Univ Catolica Portuguesa, Fac Engn, Estr Octavio Pato, P-2635631 Rio De Mouro, Portugal
[4] CHU Vaudois, Dept Radiol, Lausanne, Switzerland
[5] Univ Lausanne UNIL, Lausanne, Switzerland
[6] Univ Lisbon, Inst Super Tecn, Lab Protecao & Seguranca Radiol, Estrada Nacl 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[7] UL, IST, C2TN, EN 10 Ao Km 139,7, P-2986066 Bobadela, Portugal
[8] Guys & St Thomas NHS Fdn Trust, London, England
关键词
BREAST SCREENING-PROGRAM; DIAGNOSTIC REFERENCE LEVELS; FIELD DIGITAL MAMMOGRAPHY; DOSIMETRY; UK; PROTOCOLS; DENSITY; PHANTOM; 6-YEAR;
D O I
10.1093/rpd/ncx300
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To characterise the mean glandular dose (MGD) in a sample of healthcare providers for digital mammography in Portugal. To compare the achieved values with European references. The MGD was measured on a poly-methyl-methacrylate phantom (45 mm) for each system using dosimeters. In addition, MGD was estimated using exposure settings collected from mammography exams in clinical context. Data were collected from 25 computed-radiography systems (CR) and 13 integrated digital (DR). For both measurements (phantom and clinical exposures), the average MGD for CR was higher compared to the DR. For CR the mean MGD was 1.85 mGy (CC projection) and 2.10 mGy (MLO projection). For DR systems the corresponding values were 1.54 mGy (CC) and 1.68 mGy (MLO). The average MGD obtained using both methods and for both technologies is within the acceptable reference range proposed by European guidelines (<2.5 mGy). Dose Reference Levels implementation should be the next step to optimise mammography practice in Portugal.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 33 条
  • [1] [Anonymous], EUROPEAN GUIDELINES
  • [2] Baldelli P, 2011, RADIAT PROT DOSIM, V145, P52, DOI [10.1093/rpd/ncq375, 10.1093/rpd/ncc1375]
  • [3] A study to determine the differences between the displayed dose values for two full-field digital mammography units and values calculated using a range of Monte-Carlo-based techniques: a phantom study
    Borg, M.
    Badr, I.
    Royle, G. J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (02) : 217 - 228
  • [4] Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols
    Dance, D. R.
    Young, K. C.
    van Engen, R. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) : 453 - 471
  • [5] Breast dosimetry
    Dance, DR
    Skinner, CL
    Carlsson, GA
    [J]. APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 185 - 203
  • [6] Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    Dance, DR
    Skinner, CL
    Young, KC
    Beckett, JR
    Kotre, CJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) : 3225 - 3240
  • [7] MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE
    DANCE, DR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) : 1211 - 1219
  • [8] European Commission, 1996, European protocol on dosimetry in mammography
  • [9] Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields
    Fartaria, M. J.
    Reis, C.
    Pereira, J.
    Pereira, M. F.
    Cardoso, J. V.
    Santos, L. M.
    Oliveira, C.
    Holovey, V.
    Pascoal, A.
    Alves, J. G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17) : 6384 - 6399
  • [10] Evaluation of mammographic density patterns: reproducibility and concordance among scales
    Garrido-Estepa, Macarena
    Ruiz-Perales, Francisco
    Miranda, Josefa
    Ascunce, Nieves
    Gonzalez-Romn, Isabel
    Sanchez-Contador, Carmen
    Santamarina, Carmen
    Moreo, Pilar
    Vidal, Carmen
    Peris, Merce
    Moreno, Maria P.
    Vaquez-Carrete, Jose A.
    Collado-Garcia, Francisca
    Casanova, Francisco
    Ederra, Maria
    Salas, Dolores
    Pollan, Marina
    [J]. BMC CANCER, 2010, 10